Dosimetric comparison of the specific anthropomorphic mannequin (SAM) to 14 anatomical head models using a novel definition for the mobile phone positioning

被引:57
|
作者
Kainz, W
Christ, A
Kellom, T
Seidman, S
Nikoloski, N
Beard, B
Kuster, N
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
[2] ITIS, Fdn Res Informat Technol Soc, CH-8004 Zurich, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 14期
关键词
D O I
10.1088/0031-9155/50/14/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents new definitions for obtaining reproducible results in numerical phone dosimetry. Numerous numerical dosimetric studies have been published about the exposure of mobile phone users which concluded with conflicting results. However, many of these studies lack reproducibility due to shortcomings in the description of the phone positioning. The new approach was tested by two groups applying two different numerical program packages to compare the specific anthropomorphic mannequin (SAM) to 14 anatomically correct head models. A novel definition for the positioning of mobile phones next to anatomically correct head models is given along with other essential parameters to be reported. The definition is solely based on anatomical characteristics of the head. A simple up-to-date phone model was used to determine the peak spatial specific absorption rate (SAR) of mobile phones in SAM and in the anatomically correct head models. The results were validated by measurements. The study clearly shows that SAM gives a conservative estimate of the exposure in anatomically correct head models for head only tissue. Depending on frequency, phone position and head size the numerically calculated 10 g averaged SAR in the pinna can be up to 2.1 times greater than the peak spatial SAR in SAM. Measurements in small structures, such as the pinna, will significantly increase the uncertainty; therefore SAM was designed for SAR assessment in the head only. Whether SAM will provide a conservative value for the pinna depends on the pinna SAR limit of the safety standard considered.
引用
收藏
页码:3423 / 3445
页数:23
相关论文
共 4 条
  • [1] Specific absorption rate assessment of fifth generation mobile phones with specific anthropomorphic mannequin model and high-resolution anatomical head model
    Zhang, Huan Huan
    Gong, Li Feng
    Wang, Jun
    Sha, Wei E., I
    Li, Long
    Wang, Jian Xiao
    Wang, Chen
    INTERNATIONAL JOURNAL OF RF AND MICROWAVE COMPUTER-AIDED ENGINEERING, 2022, 32 (07)
  • [2] SAR Comparison of SAM Phantom and Anatomical Head Models for a Typical Bar-Type Phone Model
    Lee, Ae-Kyoung
    Hong, Seon-Eui
    Kwon, Jong-Hwa
    Choi, Hyung-Do
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2015, 57 (05) : 1281 - 1284
  • [3] Dosimetric Evaluation of Specific Absorption Rate in Realistic Head Models with Different Sizes in Mobile Phone Usage
    Lu, Mai
    Ueno, Shoogo
    2014 XXXITH URSI GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM (URSI GASS), 2014,
  • [4] Study on SARs in head models with different shapes by age using SAM model for mobile phone exposure at 835 MHz
    Lee, Ae-Kyoung
    Choi, Hyung-Do
    Choi, Jae-Ick