Determination of liquid hold-up and flow distribution inside modular catalytic structured packings

被引:30
作者
Viva, Aurora [1 ]
Aferka, Said [2 ]
Toye, Dominique [2 ]
Marchot, Pierre [2 ]
Crine, Michel [2 ]
Brunazzi, Elisabetta [1 ]
机构
[1] Univ Pisa, Dept Chem Engn DICCISM, I-56126 Pisa, Italy
[2] Univ Liege, Lab Chem Engn ULG, B-4000 Liege, Belgium
关键词
Liquid hold-up; Catalytic structured packing; Katapak-SP; X-ray tomography; Flow distribution; REACTIVE DISTILLATION PACKING; PRESSURE-DROP; PACKED-BEDS; PERFORMANCE; COLUMNS; AREA;
D O I
10.1016/j.cherd.2011.02.009
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents the results of a study carried out to examine liquid hold-up and flow distribution in a 0.1 m internal diameter column filled with catalytic structured packing Katapak-SP. Information has been gathered at local scale by means of a non-intrusive high energy X-ray tomograph. Measurements have been carried out in a large number of packing cross sections situated at different heights between the top and bottom of the packed column, giving access to the evolution of axial profiles of liquid hold-up in the open channels (separation zone) and in the catalytic baskets (reaction zone) as a function of the liquid load. The total hold-up, evaluated by averaging local tomographic values over the packed volume, was compared with global hold-up data obtained by traditional methods, like draining and RTD measurements. A method was also proposed to deduce the distribution of liquid flowrate, between the reaction and the separation zones, from hold-up distribution measured by tomography. The methodology was validated by comparison with experimental data obtained by collecting separately the liquid flowing out of the two zones at the bottom of the packed bed. The obtained results are invaluable to improve the description of hydrodynamics in rate based performance models. (C) 2011 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1414 / 1426
页数:13
相关论文
共 31 条
[1]   Tomographic measurement of liquid hold up and effective interfacial area distributions in a column packed with high performance structured packings [J].
Aferka, S. ;
Viva, A. ;
Brunazzi, E. ;
Marchot, P. ;
Crine, M. ;
Toye, D. .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (14) :3413-3422
[2]   LIQUID LOAD POINT DETERMINATION IN A REACTIVE DISTILLATION PACKING BY X-RAY TOMOGRAPHY [J].
Aferka, S. ;
Viva, A. ;
Brunazzi, E. ;
Marchot, P. ;
Crine, M. ;
Toye, D. .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2010, 88 (04) :611-617
[3]  
AFERKA S, 2010, THESIS U LIEGE
[4]   In situ measurements of the static liquid holdup in Katapak-SP12™ packed column using X-ray tomography [J].
Aferka, Saied ;
Crine, Michel ;
Saroha, Anil K. ;
Toye, Dominique ;
Marchot, Pierre .
CHEMICAL ENGINEERING SCIENCE, 2007, 62 (21) :6076-6080
[5]   Liquid flow behavior in catalyst-containing pockets of modular catalytic structured packing katapak SP [J].
Behrens, M. ;
Olujic, Z. ;
Jansens, P. J. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2007, 46 (12) :3884-3890
[6]   Combining reaction with distillation - Hydrodynamic and mass transfer performance of modular catalytic structured packings [J].
Behrens, M. ;
Olujic, Z. ;
Jansens, P. J. .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2006, 84 (A5) :381-389
[7]   Liquid Holdup in Catalyst-Containing Pockets of a Modular Catalytic Structured Packing [J].
Behrens, Marcel ;
Olujic, Zarko ;
Jansens, Pieter J. .
CHEMICAL ENGINEERING & TECHNOLOGY, 2008, 31 (11) :1630-1637
[8]   Prediction of pressure drop and liquid saturation in trickle-bed reactors operated in high interaction regimes [J].
Benkrid, K ;
Rode, S ;
Midoux, N .
CHEMICAL ENGINEERING SCIENCE, 1997, 52 (21-22) :4021-4032
[9]   Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system [J].
Boyer, C ;
Fanget, B .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (07) :1079-1089
[10]  
BRUNAZZI E, 2006, ICHEME S SER, V11, P554