Biocompatibility, cell growth and clinical relevance of synthetic meshes and biological matrixes for internal support in implant-based breast reconstruction

被引:22
作者
Dieterich, Max [1 ,2 ]
Stubert, Johannes [1 ,2 ]
Gerber, Bernd [1 ]
Reimer, Toralf [1 ]
Richter, Dagmar-Ulrike [2 ]
机构
[1] Univ Rostock, Dept Obstet & Gynecol, Breast Unit, Interdisciplinary Breast Ctr, D-18059 Rostock, Germany
[2] Univ Rostock, Dept Obstet & Gynecol, Res Lab, Interdisciplinary Breast Ctr, D-18059 Rostock, Germany
关键词
Strattice; TiLOOP Bra; SERAGYN BR; Breast reconstruction; Biocompatibility; Mesh; Matrix; ADM; Internal support; ACELLULAR DERMAL MATRIX; POLYPROPYLENE MESH; FOLLOW-UP; COMPLICATIONS; STRATTICE; RISK;
D O I
10.1007/s00404-014-3578-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Biological matrixes and synthetic meshes are increasingly used in implant-based breast reconstruction (IBBR). The objective was to test different materials used for internal support in IBBR in regards to biocompatibility and discuss possible limitations in a clinical context. In vitro investigations were performed on four relevant cell lines: Normal Human Dermal Fibroblasts (NHDF), Human White Preadipocytes (HWP), Endothelial cells (HDMEC) and Skeletal muscle cells (SkMC). A titanium-coated polypropylene mesh (TiLOOPA (R) Bra), a partially resorbable mesh (SERAGYN BRA (R)) and a porcine derived biologic matrix (Strattice (TM)) were investigated. Test of cytotoxicity, cell proliferation and oxidative stress was performed. Real-time cell analysis was used to determine adhesion rate. Light- and scanning electron microscopy investigated cell migration. No relevant cytotoxicity was detected for any mesh or matrix. Good cell proliferation was observed in all materials with best results for NHDF and SkMC. For HWP and HDMEC decreased proliferation and adherence to the synthetic meshes and biologic matrix were observed. Real-time cell analysis of fibroblasts incubated with the corresponding material, showed increased impedance for the synthetic meshes. A morphologic cell change was observed within all materials. Scanning electron microscopy showed good cell penetration into the meshes and matrix. The material compositions did not seem to influence the clinical outcome, although the biological matrix was much thicker compared to the synthetic meshes. Biochemical examination showed good biocompatibility for the investigated meshes and matrix. All products seem to have their value in IBBR and can be recommended for IBBR.
引用
收藏
页码:1371 / 1379
页数:9
相关论文
共 26 条
  • [1] A Paradigm Shift in US Breast Reconstruction: Increasing Implant Rates
    Albornoz, Claudia R.
    Bach, Peter B.
    Mehrara, Babak J.
    Disa, Joseph J.
    Pusic, Andrea L.
    McCarthy, Colleen M.
    Cordeiro, Peter G.
    Matros, Evan
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 131 (01) : 15 - 23
  • [2] Titanium-coated polypropylene mesh (TiLoop Bra®) - An effective prevention for capsular contracture?
    Bergmann P.A.
    Becker B.
    Mauss K.L.
    Liodaki M.E.
    Knobloch J.
    Mailänder P.
    Siemers F.
    [J]. European Journal of Plastic Surgery, 2014, 37 (6) : 339 - 346
  • [3] The innate oxygen dependant immune pathway as a sensitive parameter to predict the performance of biological graft materials
    Bryan, Nicholas
    Ashwin, Helen
    Smart, Neil
    Bayon, Yves
    Scarborough, Nelson
    Hunt, John A.
    [J]. BIOMATERIALS, 2012, 33 (27) : 6380 - 6392
  • [4] Implant-Based Breast Reconstruction Using Acellular Dermal Matrix and the Risk of Postoperative Complications
    Chun, Yoon S.
    Verma, Kapil
    Rosen, Heather
    Lipsitz, Stuart
    Morris, Donald
    Kenney, Pardon
    Eriksson, Elof
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (02) : 429 - 436
  • [5] Immediate Tissue Expander/Implant Breast Reconstruction after Salvage Mastectomy for Cancer Recurrence following Lumpectomy/Irradiation
    Cordeiro, Peter G.
    Snell, Laura
    Heerdt, Alexandra
    McCarthy, Colleen
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 129 (02) : 341 - 350
  • [6] Daly KA, 2009, TISSUE ENG PT A, V15, P3877, DOI [10.1089/ten.tea.2009.0089, 10.1089/ten.TEA.2009.0089]
  • [7] A short-term follow-up of implant based breast reconstruction using a titanium-coated polypropylene mesh (TiLoop® Bra)
    Dieterich, M.
    Reimer, T.
    Dieterich, H.
    Stubert, J.
    Gerber, B.
    [J]. EJSO, 2012, 38 (12): : 1225 - 1230
  • [8] Using a titanium-coated polypropylene mesh (TiLOOP® Bra) for implant-based breast reconstruction: case report and histological analysis
    Dieterich, M.
    Dieterich, H.
    Timme, S.
    Reimer, T.
    Gerber, B.
    Stubert, J.
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2012, 286 (01) : 273 - 276
  • [9] Implant-Based Breast Reconstruction Using a Titanium-Coated Polypropylene Mesh (TiLOOP Bra): A Multicenter Study of 231 Cases
    Dieterich, Max
    Paepke, Stefan
    Zwiefel, Karin
    Dieterich, Holger
    Blohmer, Jens
    Faridi, Andree
    Klein, Evelyn
    Gerber, Bernd
    Nestle-Kraemling, Carolin
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2013, 132 (01) : 8E - 19E
  • [10] Patient selection and technical considerations in nipple-sparing and areola-sparing mastectomy
    Dieterich M.
    Gerber B.
    [J]. Current Breast Cancer Reports, 2011, 3 (2) : 79 - 87