Contour scanning, multi-leaf collimation and the combination thereof for proton pencil beam scanning

被引:13
|
作者
Winterhalter, Carla [1 ,2 ]
Meier, Gabriel [1 ]
Oxley, David [1 ]
Weber, Damien C. [1 ,3 ,4 ]
Lomax, Antony J. [1 ,2 ]
Safai, Sairos [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Phys Dept, Zurich, Switzerland
[3] Univ Hosp Bern, Radiat Oncol Dept, Bern, Switzerland
[4] Univ Hosp Zurich, Radiat Oncol Dept, Zurich, Switzerland
关键词
proton therapy; pencil beam scanning; penumbra; collimation; optimisation; PATIENT-SPECIFIC APERTURE; MONTE-CARLO; DYNAMIC COLLIMATION; THERAPY; SYSTEM; RECONSTRUCTION; PENUMBRA; QUALITY; IMPACT;
D O I
10.1088/1361-6560/aaf2e8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In proton therapy, the lateral fall-off is often used to spare critical organs. It is therefore crucial to improve the penumbra for proton pencil beam scanning. However, previous work has shown that collimation may not be necessary for depths of >15 cm in water. As such, in this work we investigate the effectiveness of a thin multi leaf collimator (just thick enough to completely stop protons with ranges of <15 cm in water) for energy layer specific collimation in patient geometries, when applied in combination with both grid and contour scanned PBS proton therapy. For this, an analytical model of collimated beam shapes, based solely on data available in the treatment planning system, has been included in the optimization, with the resulting optimised plans then being recalculated using Monte Carlo in order to most accurately simulate the full physics effects of the collimator. For grid based scanning, energy specific collimation has been found to reduce the V30 outside the PTV by 19.8% for an example patient when compared to the same pencil beam placement without collimation. V30 could be even reduced by a further 5.6% when combining collimation and contour scanning. In addition, mixed plans, consisting of contour scanning for deep fields (max range >15 cm WER) and collimated contour scanning for superficial fields (<15 cm), have been created for four patients, by which V30 could be reduced by 0.8% to 8.0% and the mean dose to the brain stem by 1.5% to 3.3%. Target dose homogeneity however is not substantially different when compared to the best un-collimated scenario. In conclusion, we demonstrate the potential advantages of a thin, multi leaf collimator in combination with contour scanning for energy layer specific collimation in PBS proton therapy.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [2] Validation of pencil beam scanning proton therapy with multi-leaf collimator calculated by a commercial Monte Carlo dose engine
    Tominaga, Yuki
    Sakurai, Yusuke
    Miyata, Junya
    Harada, Shuichi
    Akagi, Takashi
    Oita, Masataka
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [3] Contour scanning for penumbra improvement in pencil beam scanned proton therapy
    Meier, G.
    Leiser, D.
    Besson, R.
    Mayor, A.
    Safai, S.
    Weber, D. C.
    Lomax, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06) : 2398 - 2416
  • [4] A study of lateral fall-off (penumbra) optimisation for pencil beam scanning (PBS) proton therapy
    Winterhalter, C.
    Lomax, A.
    Oxley, D.
    Weber, D. C.
    Safai, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [5] Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy
    Hyer, Daniel E.
    Bennett, Laura C.
    Geoghegan, Theodore J.
    Bues, Martin
    Smith, Blake R.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (01) : 73 - 83
  • [6] Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Gutierrez, Alonso N.
    Boland, Thibault
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [7] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05)
  • [8] Experimental fluence-modulated proton computed tomography by pencil beam scanning
    Dedes, George
    Johnson, Robert P.
    Pankuch, Mark
    Detrich, Nick
    Pols, Willemijn M. A.
    Rit, Simon
    Schulte, Reinhard W.
    Parodi, Katia
    Landry, Guillaume
    MEDICAL PHYSICS, 2018, 45 (07) : 3287 - 3296
  • [9] Collimated proton pencil-beam scanning for superficial targets: impact of the order of range shifter and aperture
    Baeumer, C.
    Janson, M.
    Timmermann, B.
    Wulff, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (08)
  • [10] Dose distribution effects of spot-scanning proton beam therapy equipped with a multi-leaf collimator for pediatric brain tumors
    Fukumitsu, Nobuyoshi
    Yamashita, Tomohiro
    Mima, Masayuki
    Demizu, Yusuke
    Suzuki, Takeshi
    Soejima, Toshinori
    ONCOLOGY LETTERS, 2021, 22 (02)