Hemodynamic evaluation in pregnancy: limitations of impedance cardiography

被引:19
作者
Moertl, Manfred G. [2 ,3 ]
Schlembach, Dietmar [2 ,4 ]
Papousek, Ilona [5 ]
Hinghofer-Szalkay, Helmut [1 ]
Weiss, Elisabeth M. [5 ]
Lang, Uwe [2 ]
Lackner, Helmut K. [1 ,6 ]
机构
[1] Med Univ Graz, Inst Physiol, Graz, Austria
[2] Med Univ Graz, Dept Obstet & Gynecol, Graz, Austria
[3] Ctr Clin, Dept Obstet & Gynecol, Klagenfurt, Austria
[4] Prenatal Med Ctr Munich, Munich, Germany
[5] Karl Franzens Univ Graz, Dept Psychol, Graz, Austria
[6] Graz Univ Technol, Inst Med Engn, A-8010 Graz, Austria
关键词
stroke volume; cardiac output; repeated measures; non-invasive technique; ICG; CARDIAC-OUTPUT; AORTOCAVAL COMPRESSION; BIOIMPEDANCE; PERFORMANCE; 2ND-HALF;
D O I
10.1088/0967-3334/33/6/1015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Impedance cardiography (ICG) has been proposed to estimate the stroke volume (SV) and cardiac output (CO) in various medical indications. The aim of this study was to explore the reliability of ICG during pregnancy with respect to SV and CO measurements. Blood pressure, heart rate and thoracic impedance were monitored during the course of pregnancy and related ICG patterns analyzed. We determined thoracic impedance (Z(0)), left ventricular ejection time (LVET) and the maximum value of the first derivative of the impedance waveform (dZ/dt)(max) beat-to-beat. The two main components of non-invasive SV estimation, LVET and (dZ/dt)(max), decreased in week 35 relative to week 12 by 7.6% +/- 4.8% and by 36.0% +/- 14.0%, respectively, based on a decrease in R-R interval of 9.9% +/- 9.7%, whereas changes in Z(0) did not play a significant role. Furthermore, the decrease of (dZ/dt)(max) was greater in the third compared to the second trimester of pregnancy. Taking into account an 18.2% +/- 6.8% body weight increase, the calculated SV decreased in week 35 relative to week 12 by 19.2% +/- 14.3%. The normalized term ((dZ/dt)(max))/Z(0) explained 85-94% of the variance of SV change after week 20. These results were confirmed for fixed R-R interval at a constant value across the repeated measurements. Based on beat-to-beat analysis of the main components of non-invasive SV estimation by ICG, measured repeatedly throughout normal pregnancy, we conclude that SV calculations render invalid data. Our findings strongly suggest that CO cannot be reliably assessed with ICG in pregnant women.
引用
收藏
页码:1015 / 1026
页数:12
相关论文
共 36 条
  • [1] Aortocaval compression in pregnancy: The effect of changing the degree and direction of lateral tilt on maternal cardiac output
    Bamber, JH
    Dresner, M
    [J]. ANESTHESIA AND ANALGESIA, 2003, 97 (01) : 256 - 258
  • [2] A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE
    BERNSTEIN, DP
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (10) : 904 - 909
  • [3] AORTOCAVAL COMPRESSION BY UTERUS IN LATE HUMAN PREGNANCY .4. CIRCULATORY HOMEOSTASIS BY PREFERENTIAL PERFUSION OF PLACENTA
    BIENIARZ, J
    YOSHIDA, T
    ROMEROSA.G
    CURUCHET, E
    CALDEYRO.R
    CROTTOGINI, JJ
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1969, 103 (01) : 19 - +
  • [4] Physiological changes of pregnancy and monitoring
    Carlin, Andrew
    Alfirevic, Zarko
    [J]. BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2008, 22 (05) : 801 - 823
  • [5] MATERNAL PHYSIOLOGIC ADAPTATIONS TO EARLY HUMAN-PREGNANCY
    CLAPP, JF
    SEAWARD, BL
    SLEAMAKER, RH
    HISER, J
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 159 (06) : 1456 - 1460
  • [6] CENTRAL HEMODYNAMIC ASSESSMENT OF NORMAL TERM PREGNANCY
    CLARK, SL
    COTTON, DB
    LEE, W
    BISHOP, C
    HILL, T
    SOUTHWICK, J
    PIVARNIK, J
    SPILLMAN, T
    DEVORE, GR
    PHELAN, J
    HANKINS, GDV
    BENEDETTI, TJ
    TOLLEY, D
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (06) : 1439 - 1442
  • [7] VENTILATORY DRIVE AND RESPIRATORY MUSCLE FUNCTION IN PREGNANCY
    CONTRERAS, G
    GUTIERREZ, M
    BEROIZA, T
    FANTIN, A
    ODDO, H
    VILLARROEL, L
    CRUZ, E
    LISBOA, C
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (04): : 837 - 841
  • [8] Assessment of stroke volumeindex with three different bioimpedance algorithms: lack of agreement compared to thermodilution
    de Waal, Eric E. C.
    Konings, Maurits K.
    Kalkman, Cor J.
    Buhre, Wolfgang F.
    [J]. INTENSIVE CARE MEDICINE, 2008, 34 (04) : 735 - 739
  • [9] Echocardiographic assessment of cardiovascular hemodynamics in normal pregnancy
    Desai, DK
    Moodley, J
    Naidoo, DP
    [J]. OBSTETRICS AND GYNECOLOGY, 2004, 104 (01) : 20 - 29
  • [10] Duvekot J J, 1994, Obstet Gynecol Surv, V49, pS1, DOI 10.1097/00006254-199412011-00001