Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change

被引:23
作者
Mansouri, Kaweh [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
24; hour; intraocular pressure; glaucoma; Sensimed Triggerfish; fluctuations; CORNEAL BIOMECHANICAL PROPERTIES; OCULAR HYPERTENSION; TONOMETRY; TELEMETRY; PATTERN;
D O I
10.4414/smw.2012.13545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Glaucoma is the main cause of irreversible blindness and intraocular pressure (IOP) is its only modifiable risk factor. The importance of robust lowering of IOP for prevention of glaucoma onset and progression is well established. Although IOP is a dynamic parameter with individual circadian rhythms, current management usually relies on single IOP measurements during regular clinic hours performed a few times a year. Recent technological advances have provided clinicians with tools for continuous IOP monitoring during a 24 hour period in an ambulatory setting. There are two approaches being investigated. The first is permanent IOP monitoring through an implantable sensor and the other is temporary monitoring through a contact lens sensor. In this article, we discuss the shortcomings of the current gold standard for tonometry (Goldmann Applanation Tonometry) and the current experience with the first commercially available continuous 24 hour IOP monitoring technology (SENSIMED Triggerfish (R)); a telemetric contact lens sensor produced by a Swiss start-up company (Sensimed AG, Lausanne, Switzerland). Recent studies suggest that 24 hour continuous monitoring of IOP can be integrated into clinical practice and have the potential to contribute to the reduction of glaucoma-related vision loss.
引用
收藏
页数:8
相关论文
共 36 条
[1]   Continuous monitoring of circadian variations in intraocular pressure by telemetry system throughout a 12-week treatment with timolol maleate in rabbits [J].
Akaishi, T ;
Ishida, N ;
Shimazaki, A ;
Hara, H ;
Kuwayama, Y .
JOURNAL OF OCULAR PHARMACOLOGY AND THERAPEUTICS, 2005, 21 (06) :436-444
[2]  
Alward WL, 1998, AM J OPHTHALMOL, V126, P498
[3]   Clinical utility of Intraocular pressure monitoring outside of normal office hours in patients with glaucoma [J].
Barkana, Yaniv ;
Anis, Sarah ;
Liebmann, Jeffrey ;
Tello, Celso ;
Ritch, Robert .
ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) :793-797
[4]   Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial [J].
Bengtsson, Boel ;
Leske, M. Cristina ;
Hyman, Leslie ;
Heijl, Anders .
OPHTHALMOLOGY, 2007, 114 (02) :205-209
[5]   Intraocular Pressure: Modulation as Treatment for Glaucoma [J].
Caprioli, Joseph ;
Varma, Rohit .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (03) :340-344
[6]  
De Smedt S, 2011, J GLAUCOMA 0519
[7]   Diurnal variation of corneal sensitivity and thickness [J].
du Toit, R ;
Vega, JA ;
Fonn, D ;
Simpson, T .
CORNEA, 2003, 22 (03) :205-209
[8]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[9]  
GOLDMANN H, 1954, Bull Mem Soc Fr Ophtalmol, V67, P474
[10]  
Goldmann H., 1954, Bull. Mem. Soc. Fr. Ophtalmol., V67, P477