A CCD-Based Reader Combined Quantum Dots-Labeled Lateral Flow Strips for Ultrasensitive Quantitative Detection of Anti-HBs Antibody

被引:55
作者
Zhang, Xueqing [1 ]
Li, Ding [2 ]
Wang, Can [3 ]
Zhi, Xiao [1 ]
Zhang, Chunlei [1 ]
Wang, Kan [1 ]
Cui, Daxiang [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Bionano Sci & Engn, Key Lab Thin Film & Microfabricat Technol,Res Ins, Minist Educ,Natl Key Lab Micro Nano Fabricat Tech, Shanghai 200240, Peoples R China
[2] 261 Hosp PLA, Ctr Biol Diag & Therapy, Beijing 100094, Peoples R China
[3] Cent So Univ Chan Shan, Dept Surg, Changsha 410083, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
CCD; Lateral Flow Chip; Quantum Dots; HBV; Surface Antigen; Antibody; Quantitative Analysis; INSPECTION; SYSTEM; CELLS; DNA;
D O I
10.1166/jbn.2012.1401
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Herein we reported a CCD-based reader combined quantum dots-labeled lateral flow strips for ultrasensitive quantitative detection of anti-HBs antibody. The CdTe quantum dots were prepared, then were used to label Hepatitis B Virus surface antigen, and then were fabricated into lateral flow strips. The as-prepared lateral flow strips were used to test different concentration of anti-HBV surface antibodies. The CCD-based reader was designed and fabricated, the quantitative analysis software was compiled, and resultant CCD-based reader system was used for quantitative analysis of examined anti-HBs antibodies on the strips. Results showed that the quantum dots-labeled lateral flow strips could detect the anti-HBs antibody with the limitation concentration of 200 pg/mL, the CCD-based reader system could detect anti-HBs antibody with the sensitivity of 2 pg/mL. In conclusion, the prepared CCD-based reader combined quantum dots-labeled lateral flow strips can be used for quantitative detection of anti-HBs antibody in sera with the sensitivity of 2 pg/mL, and has great potential in applications such as ultrasensitive detection of HBV antigens or antibodies, and other tumor biomarkers in near future.
引用
收藏
页码:372 / 379
页数:8
相关论文
共 50 条
[1]  
Addae Sarah A, 2010, Nano Biomed Eng, V2, P155
[2]   The use of nanocrystals in biological detection [J].
Alivisatos, P .
NATURE BIOTECHNOLOGY, 2004, 22 (01) :47-52
[3]  
Aslan Kadir, 2010, Nano Biomed Eng, V2, P1
[4]   From diagnostics to therapy: Prospects of quantum dots [J].
Azzazy, Hassan M. E. ;
Mansour, Mal M. H. ;
Kazinierczak, Steven C. .
CLINICAL BIOCHEMISTRY, 2007, 40 (13-14) :917-927
[5]   A prototype of giant magnetoimpedance-based biosensing system for targeted detection of gastric cancer cells [J].
Chen, Lei ;
Bao, Chen-Chen ;
Yang, Hao ;
Li, Ding ;
Lei, Chong ;
Wang, Tao ;
Hu, Heng-Yao ;
He, Meng ;
Zhou, Yong ;
Cui, Da-Xiang .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (07) :3246-3253
[6]  
Cui D., 2010, Nano Biomed. Eng, V2, P236, DOI [10.5101/nbe.v2i4.p236-244, DOI 10.5101/NBE.V2I4.P236-244, DOI 10.5101/nbe.v2i1.p45-55]
[7]   Self-Assembly of Quantum Dots and Carbon Nanotubes for Ultrasensitive DNA and Antigen Detection [J].
Cui, Daxiang ;
Pan, Bifeng ;
Zhang, Hong ;
Gao, Feng ;
Wu, Rina ;
Wang, Jingping ;
He, Rong ;
Asahi, Toru .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :7996-8001
[8]   RECENT ADVANCES IN THE AUTOMATIC INSPECTION OF INTEGRATED-CIRCUITS FOR PATTERN DEFECTS [J].
DOM, BE ;
BRECHER, V .
MACHINE VISION AND APPLICATIONS, 1995, 8 (01) :5-19
[9]   Hepatitis B surface antigen (HBsAg) assays - Are they good enough for their current uses? [J].
Dufour, D. Robert .
CLINICAL CHEMISTRY, 2006, 52 (08) :1457-1459
[10]   Nanobiotechnology: the promise and reality of new approaches to molecular recognition [J].
Fortina, P ;
Kricka, LJ ;
Surrey, S ;
Grodzinski, P .
TRENDS IN BIOTECHNOLOGY, 2005, 23 (04) :168-173