Seismic performance improvement of base-isolated structures using a semi-active tuned mass damper

被引:139
作者
Wang, Liangkun [1 ]
Nagarajaiah, Satish [2 ,3 ]
Shi, Weixing [1 ]
Zhou, Ying [1 ,4 ]
机构
[1] Tongji Univ, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
[2] Rice Univ, Dept Civil & Environm Engn, Houston, TX 77005 USA
[3] Rice Univ, Dept Mech Engn & Mat Sci, Houston, TX 77005 USA
[4] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Semi -active tuned mass damper; Base isolation; Variable stiffness; Variable damping; Seismic response mitigation; Nonlinear dynamics; ISOLATED BUILDINGS; NEGATIVE STIFFNESS; MITIGATION; TRANSFORM; SYSTEM;
D O I
10.1016/j.engstruct.2022.114963
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Base isolation can achieve a reduction in floor acceleration and inter-story drift. However, it may suffer from excessive displacements under near-fault and far-field earthquakes. To improve the aseismic performance of passive base-isolated structures, in this paper, a semi-active tuned mass damper (STMD) with variable stiffness and damping is presented. A combined control algorithm based on output signals only is developed for the STMD first. Then, the STMD is applied to an eight-story linear base-isolated structure and also a nonlinear one. As for the linear model, which represents a theoretical benchmark, an optimized passive TMD (PTMD) is used for comparison. As for the nonlinear model, lead rubber bearing (LRB) is considered and simulated using the well-known Bouc-Wen model. Eight earthquakes with different spectral characteristics and peak ground amplitudes are chosen, and two PTMDs are optimized for comparison, while one is tuned to the pre-yield period of the base -isolated model and the other is tuned to the post-yield period of the base-isolated model. Numerical results show that, generally, STMD has the best control effect in both linear and nonlinear models. For displacement re-sponses, because STMD can vary its stiffness and damping, it can mitigate the structural first-mode response effectively, and can achieve both top story and isolated level responses reduction. As for acceleration responses of the top story, STMD achieves excellent performance in the structural second-mode acceleration response miti-gation. Therefore, STMD can improve both displacement and acceleration performances of both linear and nonlinear base-isolated structures effectively.
引用
收藏
页数:16
相关论文
共 46 条
[1]  
[Anonymous], PEER Ground Motion Database
[2]   Optimal design and seismic performance of tuned mass damper inerter (TMDI) for structures with nonlinear base isolation systems [J].
De Domenico, Dario ;
Ricciardi, Giuseppe .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (12) :2539-2560
[3]   An enhanced base isolation system equipped with optimal tuned mass damper inerter (TMDI) [J].
De Domenico, Dario ;
Ricciardi, Giuseppe .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2018, 47 (05) :1169-1192
[4]  
Den Hartog J., 1956, Mechanical Vibration, V4th ed.
[5]   Simplified analytical solution for the optimal design of Tuned Mass Damper Inerter for base isolated structures [J].
Di Matteo, A. ;
Masnata, C. ;
Pirrotta, A. .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 134
[6]   Use of semi-active tuned mass dampers to control footbridges subjected to synchronous lateral excitation [J].
Ferreira, Fernando ;
Moutinho, Carlos ;
Cunha, Alvaro ;
Caetano, Elsa .
JOURNAL OF SOUND AND VIBRATION, 2019, 446 :176-194
[7]   Base-isolated structure equipped with tuned liquid column damper: An experimental study [J].
Furtmueller, Thomas ;
Di Matteo, Alberto ;
Adam, Christoph ;
Pirrotta, Antonina .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 116 :816-831
[8]   Experimental realisation of the real-time controlled smart magnetorheological elastomer seismic isolation system with shake table [J].
Gu, Xiaoyu ;
Li, Jianchun ;
Li, Yancheng .
STRUCTURAL CONTROL & HEALTH MONITORING, 2020, 27 (01)
[9]   Exploring the effects of tuned mass dampers on the seismic performance of structures with nonlinear base isolation systems [J].
Hessabi, Reza Mirza ;
Mercan, Oya ;
Ozturk, Baki .
EARTHQUAKES AND STRUCTURES, 2017, 12 (03) :285-296
[10]   Advanced vibration isolation technique using versatile electromagnetic shunt damper with tunable behavior [J].
Li, Jin-Yang ;
Zhu, Songye .
ENGINEERING STRUCTURES, 2021, 242