Validation of an automated home blood pressure measurement device in oldest-old populations

被引:9
作者
Godai, Kayo [1 ]
Kabayama, Mai [1 ]
Saito, Kanako [2 ]
Asayama, Kei [3 ,4 ]
Yamamoto, Koichi [5 ]
Sugimoto, Ken [5 ]
Ohkubo, Takayoshi [3 ,4 ]
Rakugi, Hiromi [5 ]
Kamide, Kei [1 ,5 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Hlth Sci, Osaka, Japan
[2] Omron Healthcare Co Ltd, Kyoto, Japan
[3] Teikyo Univ, Dept Hyg & Publ Hlth, Sch Med, Tokyo, Japan
[4] Tohoku Inst Management Blood Pressure, Sendai, Miyagi, Japan
[5] Osaka Univ, Dept Geriatr & Gen Med, Grad Sch Med, Osaka, Japan
关键词
Blood pressure; Validation; Oldest-old; Oscillometric device; ISO; 81060-2; ANTHROPOMETRIC REFERENCE DATA; INTERNATIONAL-PROTOCOL; EUROPEAN-SOCIETY; ANSI/AAMI/ISO; 81060-2/2013; HYPERTENSION; AGE; ASSOCIATION; PREVALENCE; STIFFNESS; AWARENESS;
D O I
10.1038/s41440-019-0330-7
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Despite the wide use of automated devices for the self-measurement of home blood pressure (BP), no evidence is available regarding the accuracy of such devices in oldest-old populations. The aim of this study was to validate the accuracy of the automated oscillometric upper arm-cuff BP-monitoring device according to an international protocol in oldest-old individuals. In 35 participants aged over 85 years old, BP was measured on the same arm sequentially using a mercury sphygmomanometer (by two observers) and an Omron HEM-7080IC. The difference between the test device and observer measurements and associated factors were evaluated according to the International Organization for Standardization (ISO) 81060-2:2013 protocol. A total of 105 pairs (three pairs per participant) of the test device and observer BP measurements were obtained. The mean (+/- standard deviation: SD) differences in systolic BP (SBP) and diastolic BP (DBP) between the methods were -0.7 +/- 7.1 and -1.1 +/- 4.5 mmHg, respectively, and those for each participant were -0.7 +/- 5.8 mmHg for SBP and -1.1 +/- 4.1 mmHg for DBP; the device therefore fulfilled the requirements of the ISO protocol. In the multivariate analysis with the linear mixed model, the difference was associated with the cuff size for SBP and pulse pressure for DBP. The Omron HEM-7080IC passed the ISO requirements for oldest-old individuals aged 85 years or older. This device can be recommended for clinical and self/home use in oldest-old populations.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 39 条
[21]  
ISO, 2013, 8106022013 ISO
[22]   POSTPRANDIAL HYPOTENSION - EPIDEMIOLOGY, PATHOPHYSIOLOGY, AND CLINICAL MANAGEMENT [J].
JANSEN, RWMM ;
LIPSITZ, LA .
ANNALS OF INTERNAL MEDICINE, 1995, 122 (04) :286-295
[23]   Implications of blood pressure variations in older populations [J].
Kamide, Kei ;
Kabayama, Mai .
HYPERTENSION RESEARCH, 2019, 42 (01) :19-25
[24]   Hypertension in adults across the age spectrum - Current outcomes and control in the community [J].
Lloyd-Jones, DM ;
Evans, JC ;
Levy, D .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (04) :466-472
[25]   Prevalence, Awareness, and Management of Hypertension, Dyslipidemia, and Diabetes Among United States Adults Aged 65 and Older [J].
McDonald, Margaret ;
Hertz, Robin P. ;
Unger, Alan N. ;
Lustik, Michael B. .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2009, 64 (02) :256-263
[26]   Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults [J].
O'Brien, E ;
Pickering, T ;
Asmar, R ;
Myers, M ;
Parati, G ;
Staessen, J ;
Mengden, T ;
Imai, Y ;
Waeber, B ;
Palatini, P ;
Atkins, N ;
Gerin, W .
BLOOD PRESSURE MONITORING, 2002, 7 (01) :3-17
[27]   Aortic diameter, aortic stiffness, and wave reflection increase with age and isolated systolic hypertension [J].
O'Rourke, MF ;
Nichols, WW .
HYPERTENSION, 2005, 45 (04) :652-658
[28]  
OBrien E, 1996, J HUM HYPERTENS, V10, P565
[29]   AN OUTLINE OF THE REVISED BRITISH-HYPERTENSION-SOCIETY PROTOCOL FOR THE EVALUATION OF BLOOD-PRESSURE MEASURING DEVICES [J].
OBRIEN, E ;
PETRIE, J ;
LITTLER, W ;
DESWIET, M ;
PADFIELD, PL ;
ALTMAN, DG ;
BLAND, M ;
COATS, A ;
ATKINS, N .
JOURNAL OF HYPERTENSION, 1993, 11 (06) :677-679
[30]   Validation of the Omron M5-1, 145-1 and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension [J].
Omboni, Stefano ;
Riva, Isabella ;
Giglio, Alessia ;
Caldara, Gianluca ;
Groppelli, Antonella ;
Parati, Gianfranco .
BLOOD PRESSURE MONITORING, 2007, 12 (04) :233-242