Validation of an automated home blood pressure measurement device in oldest-old populations

被引:8
作者
Godai, Kayo [1 ]
Kabayama, Mai [1 ]
Saito, Kanako [2 ]
Asayama, Kei [3 ,4 ]
Yamamoto, Koichi [5 ]
Sugimoto, Ken [5 ]
Ohkubo, Takayoshi [3 ,4 ]
Rakugi, Hiromi [5 ]
Kamide, Kei [1 ,5 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Hlth Sci, Osaka, Japan
[2] Omron Healthcare Co Ltd, Kyoto, Japan
[3] Teikyo Univ, Dept Hyg & Publ Hlth, Sch Med, Tokyo, Japan
[4] Tohoku Inst Management Blood Pressure, Sendai, Miyagi, Japan
[5] Osaka Univ, Dept Geriatr & Gen Med, Grad Sch Med, Osaka, Japan
关键词
Blood pressure; Validation; Oldest-old; Oscillometric device; ISO; 81060-2; ANTHROPOMETRIC REFERENCE DATA; INTERNATIONAL-PROTOCOL; EUROPEAN-SOCIETY; ANSI/AAMI/ISO; 81060-2/2013; HYPERTENSION; AGE; ASSOCIATION; PREVALENCE; STIFFNESS; AWARENESS;
D O I
10.1038/s41440-019-0330-7
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Despite the wide use of automated devices for the self-measurement of home blood pressure (BP), no evidence is available regarding the accuracy of such devices in oldest-old populations. The aim of this study was to validate the accuracy of the automated oscillometric upper arm-cuff BP-monitoring device according to an international protocol in oldest-old individuals. In 35 participants aged over 85 years old, BP was measured on the same arm sequentially using a mercury sphygmomanometer (by two observers) and an Omron HEM-7080IC. The difference between the test device and observer measurements and associated factors were evaluated according to the International Organization for Standardization (ISO) 81060-2:2013 protocol. A total of 105 pairs (three pairs per participant) of the test device and observer BP measurements were obtained. The mean (+/- standard deviation: SD) differences in systolic BP (SBP) and diastolic BP (DBP) between the methods were -0.7 +/- 7.1 and -1.1 +/- 4.5 mmHg, respectively, and those for each participant were -0.7 +/- 5.8 mmHg for SBP and -1.1 +/- 4.1 mmHg for DBP; the device therefore fulfilled the requirements of the ISO protocol. In the multivariate analysis with the linear mixed model, the difference was associated with the cuff size for SBP and pulse pressure for DBP. The Omron HEM-7080IC passed the ISO requirements for oldest-old individuals aged 85 years or older. This device can be recommended for clinical and self/home use in oldest-old populations.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 39 条
  • [1] Validation of the Omron HEM-9210T by the ANSI/AAMI/ISO 81060-2:2013 with two novel cuffs: wide-range and extra-large
    Alpert, Bruce S.
    [J]. BLOOD PRESSURE MONITORING, 2017, 22 (03) : 166 - 168
  • [2] Altunkan S, 2008, BLOOD PRESS MONIT, V13, P117, DOI 10.1097/MBP.0b013e3282f3fb50
  • [3] [Anonymous], 2016, INT POPULATION REPOR
  • [4] [Anonymous], MED REV S
  • [5] Bannerman E, 1997, BRIT MED J, V315, P338, DOI 10.1136/bmj.315.7104.338
  • [6] Barbosa Aline R., 2005, Cad. Saúde Pública, V21, P1929, DOI 10.1590/S0102-311X2005000600043
  • [7] Treatment of hypertension in patients 80 years of age or older
    Beckett, Nigel S.
    Peters, Ruth
    Fletcher, Astrid E.
    Staessen, Jan A.
    Liu, Lisheng
    Dumitrascu, Dan
    Stoyanovsky, Vassil
    Antikainen, Riitta L.
    Nikitin, Yuri
    Anderson, Craig
    Belhani, Alli
    Forette, Francoise
    Rajkumar, Chakravarthi
    Thijs, Lutgarde
    Banya, Winston
    Bulpitt, Christopher J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (18) : 1887 - 1898
  • [8] Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2:2013 protocols
    Bing, Sen
    Chen, Kang
    Hou, Hong
    Zhang, Weijuan
    Li, Linyi
    Wei, Jiao
    Shu, Chang
    Wan, Yi
    [J]. BLOOD PRESSURE MONITORING, 2016, 21 (02) : 118 - 123
  • [9] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [10] High blood pressure and bone-mineral loss In elderly white women: a prospective study
    Cappuccio, FP
    Meilahn, E
    Zmuda, JM
    Cauley, JA
    [J]. LANCET, 1999, 354 (9183) : 971 - 975