Design of Electrochemically Reduced Graphene Oxide/Titanium Disulfide Nanocomposite Sensor for Selective Determination of Ascorbic Acid

被引:26
作者
Pal, Priyanka [1 ]
Bhattacharjee, Sangya [1 ]
Das, Merina Paul [2 ]
Shim, Yoon-Bo [3 ,4 ]
Neppolian, Bernaurdshaw [1 ]
Cho, Byung Jin [5 ]
Veluswamy, Pandiyarasan [5 ,6 ]
Das, Jayabrata [1 ]
机构
[1] SRM Inst Sci & Technol, Dept Biotechnol, Sch Bioengn, Chennai 603203, Tamil Nadu, India
[2] Bharath Inst Higher Educ & Res, Dept Ind Biotechnol, Chennai 600073, Tamil Nadu, India
[3] Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
[4] Pusan Natl Univ, Inst BioPhysio Sensor Technol IBST, Busan 46241, South Korea
[5] Korea Adv Inst Sci & Technol KAIST, Sch Elect Engn, Daejeon 34141, South Korea
[6] Indian Inst Informat Technol Design & Mfg IIITDM, Sch Interdisciplinary Design & Innovat SIDI, Chennai 600127, Tamil Nadu, India
基金
新加坡国家研究基金会;
关键词
ascorbic acid; erGO/TiS2; biosensor; HPLC-MS; validation; HIGH-PERFORMANCE; OXIDE NANOCOMPOSITE; ELECTRODES; NANOSHEETS; REDUCTION; DOPAMINE; NANOPARTICLES; TEMPERATURE; BIOSENSORS;
D O I
10.1021/acsanm.1c01464
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Synthesizing conductive nanocomposites (NCs) for realizing an ultrasensitive biosensor is a prevalent technological thrust. Herein, a simple and unusual design of a sensing platform is documented using electrochemically reduced graphene oxide/titanium disulfide nanocomposite (erGO/TiS2 NC) for detection of ascorbic acid (AA): a significant neurobiological molecule. The NC is designed via sonolysis of a solution comprising ex situ-synthesized GO and TiS2 and subsequently electrochemically reduced for fabricating the sensing interface. Advanced analytical studies are carried out to support the construction of the erGO/TiS2//glassy carbon electrode (GCE). Under the optimal measuring conditions, the sensor offers two linear responses within (i) 0.1 -> 1 mu M, a limit of detection (LoD) of 30.2 nM (S/N = 3) and a sensitivity of 0.34 mu A.mu M-1.cm(-2), and (ii) 1 -> 400 mu M, a LoD of 91.4 nM and a sensitivity of 0.11 mu A.mu M-1.cm(-2) for AA. Moreover, the sensor demonstrates high selectivity toward AA over other bioanalytes except for tiny anodic responses of cysteine (7.5%) and dopamine (8.9%). Finally, the practicability of the proposed sensor has been tested for AA in pharmaceutical and human urine samples and validated by high-performance liquid chromatography-mass spectrometry (HPLC-MS). Overall, the sensor demonstrates satisfactory reliability for recovery of AA and can be considered for the diagnosis of clinical samples.
引用
收藏
页码:10077 / 10089
页数:13
相关论文
共 50 条
[21]   A Facile Hydrothermal Synthesis of Three Dimensional Flower-Like NiO-Thermally Reduced Graphene Oxide (trGO) Nanocomposite for Selective Determination of Dopamine in Presence of Uric Acid and Ascorbic Acid [J].
Aparna, T. K. ;
Sivasubramanian, R. .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2018, 18 (02) :789-797
[22]   Sensitive and Reliable Ascorbic Acid Sensing by Lanthanum Oxide/Reduced Graphene Oxide Nanocomposite [J].
Navin Kumar Mogha ;
Vikrant Sahu ;
Meenakshi Sharma ;
Raj Kishore Sharma ;
Dhanraj T. Masram .
Applied Biochemistry and Biotechnology, 2014, 174 :1010-1020
[23]   A selective determination of levodopa in the presence of ascorbic acid and uric acid using a glassy carbon electrode modified with reduced graphene oxide [J].
Yi, Soon-Young ;
Lee, Jong-Hyeok ;
Hong, Hun-Gi .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2014, 44 (05) :589-597
[24]   Construction of cationic polyfluorinated azobenzene/reduced graphene oxide for simultaneous determination of dopamine, uric acid and ascorbic acid [J].
Wu, Shining ;
Wang, Haoran ;
Zhao, Bo ;
Cao, Tongtong ;
Ma, Juanjuan ;
Liu, Lin ;
Tong, Zhiwei .
TALANTA, 2022, 237
[25]   The Electrochemical Behavior of Nafion/Reduced Graphene Oxide Modified Carbon Electrode Surface and Its Application To Ascorbic Acid Determination [J].
Liao, Wenli ;
Guo, Chaozhong ;
Sun, Lingtao ;
Li, Zhongbin ;
Tian, Liangliang ;
He, Jiahong ;
Li, Junjun ;
Zheng, Jie ;
Ma, Zili ;
Luo, Zhongli ;
Chen, Changguo .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (07) :5747-5755
[26]   Electrochemically Reduced Graphene Oxide Covalently Bound Sensor for Paracetamol Voltammetric Determination [J].
de la Vega, Amaya Paz ;
Liendo, Fabiana ;
Pichun, Bryan ;
Penagos, Johisner ;
Segura, Rodrigo ;
Aguirre, Maria Jesus .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2025, 26 (09)
[27]   Potential of Gelatin-Zinc Oxide Nanocomposite as Ascorbic Acid Sensor [J].
Rawat, Kamla ;
Sharma, Anshu ;
Solanki, Pratima R. ;
Bohidar, H. B. .
ELECTROANALYSIS, 2015, 27 (10) :2448-2457
[28]   Determination of Uric Acid in Biological Fluids by Ceria Nanoparticles Doped Reduced Graphene Oxide Nanocomposite Voltammetric Sensor [J].
Deng, Peihong ;
Feng, Jinxia ;
Xiao, Jingyun ;
Wei, Yanping ;
Zuo, Jinsong ;
Li, Junhua ;
Ding, Jianhua ;
He, Quanguo .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (12)
[29]   Hydrothermal synthesis of ZnO flower-reduced graphene oxide composite for electrochemical determination of ascorbic acid [J].
Long, Wei ;
Fu, Li .
FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2017, 25 (07) :404-409
[30]   Highly Sensitive Ascorbic Acid Sensor Based on Ionic Liquid Functionalized Graphene Oxide Nanocomposite [J].
Xu, Chunli ;
Liu, Bin ;
Ning, Wenjun ;
Wang, Xuyun .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (02) :1670-1683