Diagnostic accuracy of color-coded virtual noncalcium dual-energy CT for the assessment of bone marrow edema in sacral insufficiency fracture in comparison to MRI

被引:19
|
作者
Booz, Christian [1 ]
Noeske, Jochen [1 ]
Albrecht, Moritz H. [1 ]
Lenga, Lukas [1 ]
Martin, Simon S. [1 ]
Bucher, Andreas M. [1 ]
Huizinga, Nicole A. [2 ]
Wichmann, Julian L. [1 ]
Vogl, Thomas J. [3 ]
Yel, Ibrahim [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Div Expt Imaging, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Interdisciplinary Ctr Neurosci, Frankfurt, Germany
[3] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
Dual-Energy computed tomography; Virtual noncalcium map; Magnetic resonance imaging; Sacrum; Fractures bone; Fractures stress; LESIONS; DISPLAY;
D O I
10.1016/j.ejrad.2020.109046
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the diagnostic accuracy of color-coded dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of traumatic bone marrow edema in sacral insufficiency fracture (SIF). Method: Data from 52 consecutive patients (28 women, 24 men; mean age, 61 +/- 13 years; range, 49-94 years) who had undergone third-generation dual-source CT and 3-Tesla (T) MRI due to low back pain without adequate trauma were retrospectively evaluated. Five radiologists, blinded to MRI and clinical information, independently analyzed conventional grayscale dual-energy CT series for sacral fractures according to the Denis classification. Eight weeks later, readers re-assessed all scans using color-coded VNCa reconstructions for sacral bone marrow edema. CT numbers on VNCa reconstructions were measured by a sixth radiologist. One experienced radiologist (33 years of experience in musculoskeletal [MSK] imaging), blinded to CT and clinical information, defined the reference standard by analyzing the MRI scans. The primary indices for diagnostic accuracy were sensitivity, specificity, and the area under the curve (AUC). Results: MRI revealed a total of 39 zones with SIF-associated bone marrow edema in 27 patients. In the qualitative analysis, VNCa showed high overall sensitivity (93 %) and specificity (95 %) for assessing SIF-associated bone marrow edema. The quantitative analysis of color-coded VNCa reconstructions revealed an overall AUC of 0.976. A cut-off value of -43 Hounsfield units provided a sensitivity of 85 % and a specificity of 95 % for differentiating bone marrow edema. Conclusions: Color-coded dual-energy CT VNCa reconstructions yield excellent diagnostic accuracy in the analysis of SIF-associated bone marrow edema compared to MRI.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid
    Vitali Koch
    Felix Christoph Müller
    Kasper Gosvig
    Moritz H. Albrecht
    Ibrahim Yel
    Lukas Lenga
    Simon S. Martin
    Marco Cavallaro
    Julian L. Wichmann
    Christoph Mader
    Tommaso D’Angelo
    Silvio Mazziotti
    Giuseppe Cicero
    Thomas J. Vogl
    Christian Booz
    European Radiology, 2021, 31 : 4428 - 4437
  • [2] Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid
    Koch, Vitali
    Mueller, Felix Christoph
    Gosvig, Kasper
    Albrecht, Moritz H.
    Yel, Ibrahim
    Lenga, Lukas
    Martin, Simon S.
    Cavallaro, Marco
    Wichmann, Julian L.
    Mader, Christoph
    D'Angelo, Tommaso
    Mazziotti, Silvio
    Cicero, Giuseppe
    Vogl, Thomas J.
    Booz, Christian
    EUROPEAN RADIOLOGY, 2021, 31 (07) : 4428 - 4437
  • [3] Diagnostic Value of Dual-Energy CT Virtual Noncalcium for the Assessment of Bone Marrow Edema of Wrist in Patients with Rheumatoid Arthritis
    Xu, Guodong
    Qian, Jie
    Yang, Yekun
    Ding, Yuchen
    Chen, Yingchi
    Li, Xingcan
    Zhang, Yucheng
    Jia, Zhongzheng
    ACADEMIC RADIOLOGY, 2024, 31 (09) : 3740 - 3748
  • [4] Diagnostic accuracy of color-coded virtual noncalcium reconstructions derived from portal venous phase dual-energy CT in the assessment of lumbar disk herniation
    Koch, Vitali
    Albrecht, Moritz H.
    Gruenewald, Leon D.
    Yel, Ibrahim
    Eichler, Katrin
    Gruber-Rouh, Tatjana
    Hammerstingl, Renate M.
    Burck, Iris
    Wichmann, Julian L.
    Alizadeh, Leona S.
    Vogl, Thomas J.
    Lenga, Lukas
    Mader, Christoph
    Martin, Simon S.
    Mazziotti, Silvio
    D'Angelo, Tommaso
    Booz, Christian
    EUROPEAN RADIOLOGY, 2022, 32 (04) : 2168 - 2177
  • [5] Diagnostic accuracy of color-coded virtual noncalcium reconstructions derived from portal venous phase dual-energy CT in the assessment of lumbar disk herniation
    Vitali Koch
    Moritz H. Albrecht
    Leon D. Gruenewald
    Ibrahim Yel
    Katrin Eichler
    Tatjana Gruber-Rouh
    Renate M. Hammerstingl
    Iris Burck
    Julian L. Wichmann
    Leona S. Alizadeh
    Thomas J. Vogl
    Lukas Lenga
    Christoph Mader
    Simon S. Martin
    Silvio Mazziotti
    Tommaso D’Angelo
    Christian Booz
    European Radiology, 2022, 32 : 2168 - 2177
  • [6] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Giovanni Foti
    William Mantovani
    Niccolò Faccioli
    Giacomo Crivellari
    Luigi Romano
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2021, 126 : 405 - 413
  • [7] Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Catania, Matteo
    Caia, Simone
    Romano, Luigi
    Beltramello, Alberto
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (10): : 1028 - 1036
  • [8] Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI
    Foti, Giovanni
    Mantovani, William
    Faccioli, Niccolo
    Crivellari, Giacomo
    Romano, Luigi
    Zorzi, Claudio
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2021, 126 (03): : 405 - 413
  • [9] Identification of bone marrow edema of the ankle: diagnostic accuracy of dual-energy CT in comparison with MRI
    Giovanni Foti
    Matteo Catania
    Simone Caia
    Luigi Romano
    Alberto Beltramello
    Claudio Zorzi
    Giovanni Carbognin
    La radiologia medica, 2019, 124 : 1028 - 1036
  • [10] Traumatic bone marrow edema of the calcaneus: Evaluation of color-coded virtual non-calcium dual-energy CT in a multi-reader diagnostic accuracy study
    Booz, Christian
    Noeske, Jochen
    Albrecht, Moritz H.
    Lenga, Lukas
    Martin, Simon S.
    Wichmann, Julian L.
    Huizing, Nicole A.
    Eichler, Katrin
    Nour-Eldin, Nour-Eldin A.
    Vogl, Thomas J.
    Yel, Ibrahim
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 118 : 207 - 214