Ninety-minute exclusion of acute myocardial infarction by use of quantitative point-of-care testing of myoglobin and troponin I

被引:221
作者
McCord, J
Nowak, RM
McCullough, PA
Foreback, C
Borzak, S
Tokarski, G
Tomlanovich, MC
Jacobsen, G
Weaver, WD
机构
[1] Univ Missouri, Truman Med Ctr, Sch Med, Cardiol Sect,Dept Basic Sci & Internal Med, Kansas City, MO 64108 USA
[2] Henry Ford Hosp, Dept Biostat & Res Epidemiol, Detroit, MI 48202 USA
[3] Henry Ford Hosp, Dept Emergency Med, Detroit, MI 48202 USA
[4] Henry Ford Hosp, Henry Ford Heart & Vasc Inst, Detroit, MI 48202 USA
关键词
myoglobin; creatine kinase; troponin; myocardial infarction;
D O I
10.1161/hc3801.096336
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Diagnostic strategies with ECG and serum cardiac markers have been used to rule out acute myocardial infarction in 6 to 12 hours. The present study evaluated whether a multimarker strategy that used point-of-care measurement of myoglobin, creatine kinase (CK)-MB, and troponin I could exclude acute myocardial infarction in less than or equal to3 hours. Methods and Results-We prospectively enrolled consecutive patients (n=817) in the emergency department who were evaluated for possible acute myocardial infarction. In patients with nondiagnostic ECGs, we measured CK-MB, troponin I, and myoglobin with a point-of-care device at presentation and at 90 minutes, 3 hours, and 9 hours. Standard central laboratory testing of CK-MB was done at the same time intervals, and triage decisions were made by emergency physicians who were unaware of point-of-care results. Sensitivity and negative predictive value were compared for both the multimarker, point-of-care approach and the central laboratory strategy. Sensitivity and negative predictive value for point-of-care combination of myoglobin and troponin I by 90 minutes was 96.9% and 99.6%, respectively. CK-MB measurements and blood sampling at 3 hours did not improve sensitivity or negative predictive value. Median time from sampling to reporting of results was 71.0 minutes for the central laboratory versus 24.0 minutes for the point-of-care device (P <0.001). Conclusions-Acute myocardial infarction can be excluded rapidly in the emergency department by use of point-of-care measurements of myoglobin and troponin I during the first 90 minutes after presentation.
引用
收藏
页码:1483 / 1488
页数:6
相关论文
共 25 条
  • [21] A prospective study of an algorithm using cardiac troponin I and myoglobin as adjuncts in the diagnosis of acute myocardial infarction and intermediate coronary syndromes in a veteran's hospital
    Maisel, AS
    Templin, K
    Love, M
    Clopton, P
    [J]. CLINICAL CARDIOLOGY, 2000, 23 (12) : 915 - 920
  • [22] Missed diagnoses of acute cardiac ischemia in the emergency department
    Pope, JH
    Aufderheide, TP
    Ruthazer, R
    Woolard, RH
    Feldman, JA
    Beshansky, JR
    Griffith, JL
    Selker, HP
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (16) : 1163 - 1170
  • [23] RADIOIMMUNOASSAY OF MYOGLOBIN IN HUMAN-SERUM - RESULTS IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION
    STONE, MJ
    WILLERSON, JT
    GOMEZSANCHEZ, CE
    WATERMAN, MR
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1975, 56 (05) : 1334 - 1339
  • [24] Economies, health-related quality of life, and cost-effectiveness methods for the TACTICS (treat angina with Aggrastat® [tirofiban] and determine cost of therapy with invasive or conservative strategy)-TIMI 18 trial
    Weintraub, WS
    Culler, SD
    Kosinski, A
    Becker, ER
    Mahoney, E
    Burnette, J
    Spertus, JA
    Feeny, D
    Cohen, DJ
    Krumholz, H
    Ellis, SG
    Demopoulos, L
    Robertson, D
    Boccuzzi, SJ
    Barr, E
    Cannon, CP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (03) : 317 - 322
  • [25] Wu AHB, 1998, CLIN CHEM, V44, P1198