Optimal performance of CCHP based microgrid considering environmental issue in the presence of real time demand response

被引:80
作者
Saberi, Kasra [1 ]
Pashaei-Didani, Hamed [1 ]
Nourollahi, Ramin [1 ]
Zare, Kazem [1 ]
Nojavan, Sayyad [1 ]
机构
[1] Univ Tabriz, Fac Elect & Comp Engn, POB 51666-15813, Tabriz, Iran
关键词
CCHP based microgrid; Multi-objective model; Weighted sum and fuzzy techniques; Real time demand response program; HYBRID ENERGY SYSTEM; OPTIMIZATION MODEL; OPTIMAL OPERATION; LOAD MANAGEMENT; STORAGE SYSTEM; HUBS; HEAT;
D O I
10.1016/j.scs.2018.12.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this article, an improved system in micro energy grid is investigated composing of energy hub system as combined cooling, heating and power (CCHP) based microgrid integrated with renewable energies like photovoltaic (PV) and wind turbine (WT). The main goal is to solve a multi-objective model that includes reducing carbon emission and operation cost in the presence of real time demand response program (DRP). The flexibility of suggested energy hub system is the result of utilizing three hubs, storage devices and optimal energy flow. The multi-objective model has been solved using weighted sum approach and max-min fuzzy to make the optimal Pareto solutions and select the trade-off solution, respectively. This paper implemented the priced based real time DRP to flatten the load curve by shifting some amounts of loads from peak periods to off-peak periods. Two cases studied in the article that indicates the effects of real time DRP on optimization of energy hub systems. Finally, the energy hub system model is formulated and solved using CPLEX solver in GAMS optimization software. The results show that the operation cost and carbon emission are reduced 3.97% and 2.26%, respectively due to implementation of real time DRP.
引用
收藏
页码:596 / 606
页数:11
相关论文
共 34 条
[1]   Demand response modeling considering Interruptible/Curtailable loads and capacity market programs [J].
Aalami, H. A. ;
Moghaddam, M. Parsa ;
Yousefi, G. R. .
APPLIED ENERGY, 2010, 87 (01) :243-250
[2]  
[Anonymous], NAT CLIM CHANGE
[3]  
Bahrami S S., 2013, Energy and Power Engineering, V5, P352, DOI DOI 10.4236/EPE.2013.55036
[4]   Optimal Operation of Residential Energy Hubs in Smart Grids [J].
Bozchalui, Mohammad Chehreghani ;
AhsanHashmi, Syed ;
Hassen, Hussin ;
Canizares, Claudio A. ;
Bhattacharya, Kankar .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) :1755-1766
[5]   Thermoelectric Properties of Highly Ordered Metal-Organic Framework Films [J].
Chen, Xin ;
Wang, Zhengbang ;
Lin, Pengtao ;
Zhang, Kai ;
Baumgart, Helmut ;
Redel, Engelbert ;
Woell, Christof .
EMERGING NANOMATERIALS AND DEVICES, 2016, 75 (13) :119-126
[6]   Power systems balancing with high penetration renewables: The potential of demand response in Hawaii [J].
Critz, D. Karl ;
Busche, Sarah ;
Connors, Stephen .
ENERGY CONVERSION AND MANAGEMENT, 2013, 76 :609-619
[7]  
Elsied M., 2016, ENERGY CONVERSION MA
[8]   Optimal coupling of energy infrastructures [J].
Geidl, Martin ;
Andersson, Goeran .
2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, :1398-1403
[9]   Energy hubs for the future [J].
Geidl, Martin ;
Koeppel, Gaudenz ;
Favre-Perrod, Patrick ;
Kloeckl, Bernd ;
Andersson, Goran ;
Froehlich, Klaus .
IEEE POWER & ENERGY MAGAZINE, 2007, 5 (01) :24-30
[10]   A two-stage optimal planning and design method for combined cooling, heat and power microgrid system [J].
Guo, Li ;
Liu, Wenjian ;
Cai, Jiejin ;
Hong, Bowen ;
Wang, Chengshan .
ENERGY CONVERSION AND MANAGEMENT, 2013, 74 :433-445