A Thermal Model for a CPC-Type Double-Pass Solar Air Heater

被引:2
作者
Chavez-Bermudez, Irving A. [1 ]
Ortega-Avila, Naghelli [2 ]
Venegas-Reyes, Eduardo [3 ]
机构
[1] Ctr Invest Mat Avanzados CIMAV, Dept Ingn Sustentable, 110 Ejido Arroyo Seco, Durango, Mexico
[2] Ctr Invest Mat Avanzados CIMAV, Dept Ingn Sustentable, Catedras Conacyt, 110 Ejido Arroyo Seco, Durango, Mexico
[3] Inst Mexicano Tecnol Agua, Paseo Cuauhnahuac 8532, Progreso, Mexico
来源
SOLARPACES 2020 - 26TH INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS | 2022年 / 2445卷
关键词
FORCED-CONVECTION; PERFORMANCE; COLLECTOR; LAMINAR;
D O I
10.1063/5.0086083
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The double-pass solar air heater consists of a linear CPC with a flat receiver, where the air circulates counterflow through the cavity formed by the absorber plate, the cover, and the reflectors to preheat the fluid and then incorporate it into the receiver duct. This research's objective was to demonstrate that the CPC-type double-pass heater's thermal performance is better than a conventional or single-pass CPC heater. In this sense, two one-dimensional steady-state thermal models were developed, one for each CPC-type heater. The heat transfer equations were solved in the cover, the cavity, the absorber plate, and the receiving duct, using the numerical method of control volumes. Both models were evaluated for a truncated concentrator, with a mass flow range of 0.0013 kg/s to 0.1050 kg/s, setting the global solar irradiance at 950 W/m(2), the wind speed 3 m/s, and the ambient temperature and the inlet temperature of the fluid at 33 degrees C. In all the cases analyzed, the double pass heater provides higher outlet air temperature and instantaneous efficiency than the conventional ones, with improvements until 9.4% and 73.1%, respectively. In the double pass air heater, the air temperature at the concentrator outlet was 88.4 degrees C (with laminar flow in the receiving duct) to 37.8 degrees C (with turbulent flow), instantaneous efficiency was 7.3% to 59.0%. Based on the results obtained, it is concluded that the CPC-type double pass solar air heater allows the profiteering of the heat lost by the receiver from the pre-circulation of air through the cavity.
引用
收藏
页数:7
相关论文
共 50 条
[41]   Optical study of twin-tanked ICS solar heaters combined with asymmetrical CPC-type reflectors [J].
Souliotis, Manolis ;
Garoufalis, Christos S. ;
Vouros, Andreas P. ;
Kavga, Angeliki .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (02) :884-895
[42]   Temperature Variation of a Double-pass Solar Drying System with Porous Media [J].
Aliasak, Zalila ;
Sulaiman, Fauziah ;
Abdullah, Nurhayati .
PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 :480-483
[43]   Performance evaluation of a new counter flow double pass solar air heater with turbulators [J].
Abdullah, A. S. ;
Abou Al-sood, M. M. ;
Omara, Z. M. ;
Bek, M. A. ;
Kabeel, A. E. .
SOLAR ENERGY, 2018, 173 :398-406
[44]   Assessment of double-pass pin finned solar air heater at different air mass ratios via energy, exergy, economic, and environmental (4E) approaches [J].
Abo-Elfadl, Saleh ;
Yousef, Mohamed S. ;
Hassan, Hamdy .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (11) :13776-13789
[45]   Performance evaluation of a double pass PV/T solar air heater with and without fins [J].
Kumar, Rakesh ;
Rosen, Marc A. .
APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) :1402-1410
[46]   Recycle Effect on Device Performance of Wire Mesh Packed Double-Pass Solar Air Heaters [J].
Ho, Chii-Dong ;
Lin, Chun-Sheng ;
Yang, Tz-Jin ;
Chao, Chun-Chieh .
ENERGIES, 2014, 7 (11) :7568-7585
[47]   Performance improvement of wire mesh packed double-pass solar air heaters with external recycle [J].
Ho, Chii-Dong ;
Lin, Chun-Sheng ;
Chuang, Yu-Chuan ;
Chao, Chun-Chieh .
RENEWABLE ENERGY, 2013, 57 :479-489
[48]   Analytical and Experimental Study of Recycling Baffled Double-Pass Solar Air Heaters with Attached Fins [J].
Ho, Chii Dong ;
Chang, Hsuan ;
Wang, Rei Chi ;
Lin, Chun Sheng .
ENERGIES, 2013, 6 (04) :1821-1842
[49]   Experimental thermal performance analysis of finned tube-phase change material based double pass solar air heater [J].
Sajawal, Muhammad ;
Rehman, Tauseef-ur ;
Ali, Hafiz Muhammad ;
Sajjad, Uzair ;
Raza, Ali ;
Bhatti, Muhammad Sheheryar .
CASE STUDIES IN THERMAL ENGINEERING, 2019, 15
[50]   Performance Analysis of a Novel Photovoltaic Thermal PVT Double Pass Solar Air Heater with Cylindrical PCM Capsules using CFD [J].
Din, Sahibzada Imad Ud ;
Ibrahim, Adnan ;
Fazlizan, Ahmad ;
Ishak, Amir Aziat ;
Nawab, Faisal ;
Abd Hamid, Ag Sufiyan .
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2023, 13 (03) :1418-1430