A Thermal Model for a CPC-Type Double-Pass Solar Air Heater

被引:1
|
作者
Chavez-Bermudez, Irving A. [1 ]
Ortega-Avila, Naghelli [2 ]
Venegas-Reyes, Eduardo [3 ]
机构
[1] Ctr Invest Mat Avanzados CIMAV, Dept Ingn Sustentable, 110 Ejido Arroyo Seco, Durango, Mexico
[2] Ctr Invest Mat Avanzados CIMAV, Dept Ingn Sustentable, Catedras Conacyt, 110 Ejido Arroyo Seco, Durango, Mexico
[3] Inst Mexicano Tecnol Agua, Paseo Cuauhnahuac 8532, Progreso, Mexico
来源
SOLARPACES 2020 - 26TH INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS | 2022年 / 2445卷
关键词
FORCED-CONVECTION; PERFORMANCE; COLLECTOR; LAMINAR;
D O I
10.1063/5.0086083
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The double-pass solar air heater consists of a linear CPC with a flat receiver, where the air circulates counterflow through the cavity formed by the absorber plate, the cover, and the reflectors to preheat the fluid and then incorporate it into the receiver duct. This research's objective was to demonstrate that the CPC-type double-pass heater's thermal performance is better than a conventional or single-pass CPC heater. In this sense, two one-dimensional steady-state thermal models were developed, one for each CPC-type heater. The heat transfer equations were solved in the cover, the cavity, the absorber plate, and the receiving duct, using the numerical method of control volumes. Both models were evaluated for a truncated concentrator, with a mass flow range of 0.0013 kg/s to 0.1050 kg/s, setting the global solar irradiance at 950 W/m(2), the wind speed 3 m/s, and the ambient temperature and the inlet temperature of the fluid at 33 degrees C. In all the cases analyzed, the double pass heater provides higher outlet air temperature and instantaneous efficiency than the conventional ones, with improvements until 9.4% and 73.1%, respectively. In the double pass air heater, the air temperature at the concentrator outlet was 88.4 degrees C (with laminar flow in the receiving duct) to 37.8 degrees C (with turbulent flow), instantaneous efficiency was 7.3% to 59.0%. Based on the results obtained, it is concluded that the CPC-type double pass solar air heater allows the profiteering of the heat lost by the receiver from the pre-circulation of air through the cavity.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Thermal performance of a packed bed double-pass solar air heater
    Ramadan, M. R. I.
    El-Sebaii, A. A.
    Aboul-Enein, S.
    El-Bialy, E.
    ENERGY, 2007, 32 (08) : 1524 - 1535
  • [2] Energy and exergy analysis in double-pass solar air heater
    Velmurugan, P.
    Kalaivanan, R.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2016, 41 (03): : 369 - 376
  • [3] Energy and exergy analysis in double-pass solar air heater
    P VELMURUGAN
    R KALAIVANAN
    Sādhanā, 2016, 41 : 369 - 376
  • [4] ENHANCED DOUBLE-PASS SOLAR AIR HEATER WITH AND WITHOUT POROUS MEDIUM
    Languri, Ehsan Mohseni
    Taherian, Hessam
    Hooman, Kamel
    Reisel, John
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2011, 8 (06) : 643 - 654
  • [5] Thermal performance of a double-pass solar air heater (SAH) with ribbed absorber surface - an experimental study
    Sah, Nandkishor
    Mandapati, Mohan Jagadeesh Kumar
    WORLD JOURNAL OF ENGINEERING, 2020, 17 (03) : 373 - 380
  • [6] Thermal Evaluation of a Double-Pass Unglazed Solar Air Heater with Perforated Plate and Wire Mesh Layers
    Mahmood, Afaq Jasim
    SUSTAINABILITY, 2020, 12 (09)
  • [7] Investigation on energy, economic, and environmental aspects of double-pass solar air heater
    Vijayakumar R.
    Kumar R.V.
    Madhu P.
    Environmental Science and Pollution Research, 2024, 31 (27) : 39406 - 39420
  • [8] On the performance and entropy generation of the double-pass solar air heater with longitudinal fins
    Naphon, P
    RENEWABLE ENERGY, 2005, 30 (09) : 1345 - 1357
  • [9] Performance improvement of double-pass solar air heater - A state of art of review
    Alam, Tabish
    Kim, Man-Hoe
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 : 779 - 793
  • [10] Experimental Investigation of the Performance of a Double-Pass Unglazed Transpired Solar Air Heater
    Rabha, D. K.
    Pathak, D.
    Baruah, R.
    Kalita, T.
    Sharma, A.
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 571 - 584