Apertureless scanning near-field infrared microscopy of a rough polymeric surface

被引:46
作者
Akhremitchev, BB
Pollack, S
Walker, GC [1 ]
机构
[1] Univ Pittsburgh, Dept Chem, Chevron Sci Ctr G12, Pittsburgh, PA 15260 USA
[2] Howard Univ, Dept Chem, Washington, DC 20059 USA
关键词
D O I
10.1021/la001401v
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Infrared near-field microscopy using an apertureless probe technique has been accomplished to study the surface of a cast copolymer film. Two basic models for the predicted signal and the experimental data are presented. The first model includes plane wave light scattering by a conductive sphere and an infinitely wide absorptive layer placed on a semi-infinite conductor. This model shows infrared signal dependence on the layer absorption and predicts topographic coupling into the infrared signal. The experimental data also indicate that a significant component in the infrared contrast arises from the probe following the sample's topography, and a method to eliminate the influence of topography following is demonstrated. The images corrected by such a procedure show spatial resolution of approximately lambda /80. A more complex model based on a three-dimensional finite difference time domain method was used to calculate scattering from a rough surface. Both constant tip-sample gap and constant tip-substrate height analyses were made, and it is found that constant height imaging is a preferred mode of operation. Calculations for dielectric and Lorentzian materials are reported. These calculations indicate that the near-field infrared signal attenuation for an absorptive object is larger than for a bare layer of the same thickness. This effect may be used to enhance chemical contrast in near-field imaging.
引用
收藏
页码:2774 / 2781
页数:8
相关论文
共 50 条
[1]   Polarization contrast with an apertureless near-field optical microscope [J].
Adam, PM ;
Royer, P ;
Laddada, R ;
Bijeon, JL .
ULTRAMICROSCOPY, 1998, 71 (1-4) :327-331
[2]   Finite sample thickness effects on elasticity determination using atomic force microscopy [J].
Akhremitchev, BB ;
Walker, GC .
LANGMUIR, 1999, 15 (17) :5630-5634
[3]   Atomic force microscopy studies of hydration of fluorinated amide/urethane copolymer film surfaces [J].
Akhremitchev, BB ;
Mohney, BK ;
Marra, KG ;
Chapman, TM ;
Walker, GC .
LANGMUIR, 1998, 14 (15) :3976-3982
[4]  
[Anonymous], POLYM PREPR
[5]  
Azoulay J, 1999, J MICROSC-OXFORD, V194, P486, DOI 10.1046/j.1365-2818.1999.00558.x
[6]   NEAR-FIELD OPTICAL MICROSCOPY BY LOCAL PERTURBATION OF A DIFFRACTION SPOT [J].
BACHELOT, R ;
GLEYZES, P ;
BOCCARA, AC .
MICROSCOPY MICROANALYSIS MICROSTRUCTURES, 1994, 5 (4-6) :389-397
[7]   Characterization of organic thin film materials with near-field scanning optical microscopy (NSOM) [J].
Barbara, PF ;
Adams, DM ;
O'Connor, DB .
ANNUAL REVIEW OF MATERIALS SCIENCE, 1999, 29 :433-+
[8]   Single polymer chain elongation by atomic force microscopy [J].
Bemis, JE ;
Akhremitchev, BB ;
Walker, GC .
LANGMUIR, 1999, 15 (08) :2799-2805
[9]   Single molecule emission characteristics in near-field microscopy [J].
Bian, RX ;
Dunn, RC ;
Xie, XS ;
Leung, PT .
PHYSICAL REVIEW LETTERS, 1995, 75 (26) :4772-4775
[10]  
Bozhevolnyi SI, 1999, J MICROSC-OXFORD, V194, P561, DOI 10.1046/j.1365-2818.1999.00501.x