Non-Contact Respiratory Monitoring Using an RGB Camera for Real-World Applications

被引:30
|
作者
Romano, Chiara [1 ]
Schena, Emiliano [1 ]
Silvestri, Sergio [1 ]
Massaroni, Carlo [1 ]
机构
[1] Univ Campus Biomed Roma, Unit Measurements & Biomed Instrumentat, Via Alvaro del Portillo, I-00128 Rome, Italy
关键词
breathing; contactless monitoring systems; respiratory monitoring; RGB cameras; SLEEP; RADAR;
D O I
10.3390/s21155126
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Respiratory monitoring is receiving growing interest in different fields of use, ranging from healthcare to occupational settings. Only recently, non-contact measuring systems have been developed to measure the respiratory rate (f(R)) over time, even in unconstrained environments. Promising methods rely on the analysis of video-frames features recorded from cameras. In this work, a low-cost and unobtrusive measuring system for respiratory pattern monitoring based on the analysis of RGB images recorded from a consumer-grade camera is proposed. The system allows (i) the automatized tracking of the chest movements caused by breathing, (ii) the extraction of the breathing signal from images with methods based on optical flow (FO) and RGB analysis, (iii) the elimination of breathing-unrelated events from the signal, (iv) the identification of possible apneas and, (v) the calculation of f(R) value every second. Unlike most of the work in the literature, the performances of the system have been tested in an unstructured environment considering user-camera distance and user posture as influencing factors. A total of 24 healthy volunteers were enrolled for the validation tests. Better performances were obtained when the users were in sitting position. FO method outperforms in all conditions. In the f(R) range 6 to 60 breaths/min (bpm), the FO allows measuring f(R) values with bias of -0.03 +/- 1.38 bpm and -0.02 +/- 1.92 bpm when compared to a reference wearable system with the user at 2 and 0.5 m from the camera, respectively.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] NON-CONTACT MONITORING OF PRETERM INFANTS USING RGB-D CAMERA
    Cenci, Annalisa
    Liciotti, Daniele
    Frontoni, Emanuele
    Mancini, Adriano
    Zingaretti, Primo
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 9, 2016,
  • [2] Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
    Addison, Paul S.
    Antunes, Andre
    Montgomery, Dean
    Smit, Philip
    Borg, Ulf R.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (04) : 1003 - 1010
  • [3] Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
    Paul S Addison
    André Antunes
    Dean Montgomery
    Philip Smit
    Ulf R. Borg
    Journal of Clinical Monitoring and Computing, 2023, 37 : 1003 - 1010
  • [4] Non-Contact Heart Rate Monitoring in Neonatal Intensive Care Unit using RGB Camera
    Chen, Qiong
    Jiang, Xinyu
    Liu, Xiangyu
    Lu, Chunmei
    Wang, Laishuan
    Chen, Wei
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5822 - 5825
  • [5] A Machine Learning Method to Improve Non-Contact Heart Rate Monitoring Using an RGB Camera
    Ghanadian, Hamideh
    Ghodratigohar, Mohammad
    Al Osman, Hussein
    IEEE ACCESS, 2018, 6 : 57085 - 57094
  • [6] Non-contact Respiration Measurement by Using RGB-D Camera
    Aoki, Hirooki
    Fujita, Noriaki
    2022 JOINT 12TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS AND 23RD INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (SCIS&ISIS), 2022,
  • [7] Non-Contact Video-Based Assessment of the Respiratory Function Using a RGB-D Camera
    Valenzuela, Andrea
    Sibuet, Nicolas
    Hornero, Gemma
    Casas, Oscar
    SENSORS, 2021, 21 (16)
  • [8] Non-contact imaging of venous compliance in humans using an RGB camera
    Kazuya Nakano
    Ryota Satoh
    Akira Hoshi
    Ryohei Matsuda
    Hiroyuki Suzuki
    Izumi Nishidate
    Optical Review, 2015, 22 : 335 - 341
  • [9] Non-contact imaging of venous compliance in humans using an RGB camera
    Nakano, Kazuya
    Satoh, Ryota
    Hoshi, Akira
    Matsuda, Ryohei
    Suzuki, Hiroyuki
    Nishidate, Izumi
    OPTICAL REVIEW, 2015, 22 (02) : 335 - 341
  • [10] Automatic non-contact monitoring of the respiratory rate of neonates using a structured light camera
    Gleichauf, Johanna
    Niebler, Christine
    Koelpin, Alexander
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4118 - 4121