First Experience with the Heidelberg Edge Perimeter® on Patients with Ocular Hypertension and Preperimetric Glaucoma

被引:7
作者
Hasler, S. [1 ]
Stuermer, J. [1 ]
机构
[1] Kantonsspital, Augenklin, CH-8401 Winterthur, Switzerland
关键词
ocular hypertension; Heidelberg Edge perimeter; visual field defect; preperimetric glaucoma; FLICKER DEFINED FORM; VISUAL-FIELD;
D O I
10.1055/s-0031-1299210
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The white-on-white computerised static perimetry is not very sensitive to detect a beginning visual field loss. A newer technique to test the central visual field with a flicker defined form technology (FDF) is the Heidelberg Edge Perimeter (R) (HEP). Patients and Methods: A study with 90 eyes from 50 patients (mean age 59 +/- 14 years) with ocular hypertension and/or optic nerve suspicious for glaucoma without detectable visual field loss in the Octopus (R) perimetry (Program dG-2) with the Heidelberg Edge Perimeter (R) was performed. The "mean defect" (MD), the "pattern standard deviation" and the glaucoma hemifield test (GHT) were calculated and compared with the indices of the Octopus (R). Results: Despite normal visual field findings in the Octopus (R) perimetry (MD < 2.0 dB) we detected in 48 out of 90 eyes (53 %) pathological visual fields in the HEP examination. Conclusions: As a new research method the Heidelberg Edge perimetry (R) seems to be more sensitive than conventional static perimetry in early detection of visual field alterations in patients between ocular hypertension and incipient glaucoma.
引用
收藏
页码:319 / 322
页数:4
相关论文
共 10 条
[1]   Mapping the visual field to the optic disc in normal tension glaucoma eyes [J].
Garway-Heath, DF ;
Poinoosawmy, D ;
Fitzke, FW ;
Hitchings, RA .
OPHTHALMOLOGY, 2000, 107 (10) :1809-1815
[2]   Is flicker-defined form (FDF) dependent on the contour? [J].
Goren, Deborah ;
Flanagan, John G. .
JOURNAL OF VISION, 2008, 8 (04)
[3]  
Johnson Chris A, 2002, Curr Opin Ophthalmol, V13, P77, DOI 10.1097/00055735-200204000-00004
[4]   Learning Curve and Fatigue Effect of Flicker Defined Form Perimetry [J].
Lamparter, Julia ;
Schulze, Andreas ;
Schuff, Ann-Christin ;
Berres, Manfred ;
Pfeiffer, Norbert ;
Hoffmann, Esther M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (06) :1057-1064
[5]   A comparison of short wavelength automated perimetry with frequency doubling perimetry for the early detection of visual field loss in ocular hypertension [J].
Landers, J ;
Goldberg, I ;
Graham, S .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 28 (04) :248-252
[6]  
Lohr M, STRUKTUR FUNKTION HE
[7]  
Pfeiffer N, 2005, OPHTHALMOLOGE, V102, P230, DOI 10.1007/s00347-004-1150-x
[8]   Defining the limits of flicker defined form: effect of stimulus size, eccentricity and number of random dots [J].
Quaid, PT ;
Flanagan, JG .
VISION RESEARCH, 2005, 45 (08) :1075-1084
[9]   Diagnostic Tools for Glaucoma Detection and Management [J].
Sharma, Pooja ;
Sample, Pamela A. ;
Zangwill, Linda M. ;
Schuman, Joel S. .
SURVEY OF OPHTHALMOLOGY, 2008, 53 :S17-S32
[10]   Identification of early glaucoma cases with the scanning laser ophthalmoscope [J].
Wollstein, G ;
Garway-Heath, DF ;
Hitchings, RA .
OPHTHALMOLOGY, 1998, 105 (08) :1557-1563