Reduction of anisotropic image resolution in transmission electron microtomography by use of quadrangular prism-shaped section

被引:32
作者
Kaneko, T
Nishioka, H
Nishi, T
Jinnai, H [1 ]
机构
[1] Kyoto Inst Technol, Japan Chem Innovat Inst, Dept Polymer Sci & Engn, Kyoto 6068585, Japan
[2] Kyoto Inst Technol, Japan Chem Innovat Inst, Joint Res Ctr Project Nanostruct Polymer Mat, Kyoto 6068585, Japan
[3] Tokyo Inst Technol, Sch Sci & Engn, Dept Organ & Polymer Mat, Meguro Ku, Tokyo 1528552, Japan
来源
JOURNAL OF ELECTRON MICROSCOPY | 2005年 / 54卷 / 05期
关键词
electron tomography; image resolution; three-dimensional reconstruction; block copolymer;
D O I
10.1093/jmicro/dfi065
中图分类号
TH742 [显微镜];
学科分类号
摘要
A quadrangular prism specimen (a 'prism-shaped' section) was observed in three-dimension (3-D) by transmission electron microtomography (TEMT) over as wide a tilt range as possible. Two types of specimens were prepared for the TEMT experiments: (i) a prism-shaped section of a block copolymer nanostructure, whose cross section was 200 nm on each side and (ii) a conventional ultrathin section having the same thickness (similar to 200 nm) as the prism-shaped section. Image quality of the projections taken at high tilt angles, e.g. 60 degrees, of the prism-shaped section was considerably better than that of the ultrathin section. This was because the path length of electron beam of the prism-shaped section was shorter (and hence the transmission was higher) than that of the ultrathin section at the same tilt angle. Thus, although the projections of the ultrathin section at the tilt angle larger than similar to 40 degrees did not effectively contribute to the 3-D reconstruction, those of the prism-shaped section at very high tilt angles, e.g. +/- 75 degrees, can still be used for the 3-D reconstruction. Three orthogonal cross-sectional views of the 3-D reconstruction were extensively compared between the two sections. It was found that (i) the image contrast of the 3-D reconstruction was significantly enhanced and (ii) an elongation of structural object due to limitation of the angular range in the electron tomography was considerably reduced using the prism-shaped section.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 31 条
[1]   APPROXIMATION OF MISSING-CONE DATA IN 3D ELECTRON-MICROSCOPY [J].
BARTH, M ;
BRYAN, RK ;
HEGERL, R .
ULTRAMICROSCOPY, 1989, 31 (04) :365-378
[2]  
CARAZO JM, 1992, FIDELITY 3D RECONSTR, P117
[3]   RECONSTRUCTION OF 3 DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON MICROSCOPY [J].
CROWTHER, RA ;
DEROSIER, DJ ;
KLUG, A .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1530) :319-&
[4]  
Frank J., 1992, ELECT TOMOGRAPHY 3 D
[6]   RECONSTRUCTION OF A 3-DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON-MICROSCOPY .2. DIRECT METHODS [J].
GILBERT, PFC .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1972, 182 (1066) :89-+
[7]   Process integration of self-assembled polymer templates into silicon nanofabrication [J].
Guarini, KW ;
Black, CT ;
Zhang, Y ;
Kim, H ;
Sikorski, EM ;
Babich, IV .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2002, 20 (06) :2788-2792
[8]  
Hahn T., 2002, Space-Group Symmetry, VA, DOI DOI 10.1107/97809553602060000505
[9]   Nanostructure fabrication using block copolymers [J].
Hamley, IW .
NANOTECHNOLOGY, 2003, 14 (10) :R39-R54
[10]   Emerging technologies for the 3D analysis of polymer structures [J].
Jinnai, H ;
Nishikawa, Y ;
Ikehara, T ;
Nishi, T .
NMR - 3D ANALYSIS - PHOTOPOLYMERIZATION, 2004, 170 :115-167