Clinical Outcomes of Toric Implantable Collamer Lens (T-ICL) and Toric Implantable Phakic Contact Lens (IPCL) for High Myopia with Astigmatism: A Comparative Study

被引:0
|
作者
Mahmoud, Mohamed Salah El-Din [1 ]
AttaAllah, Heba Radi [1 ]
机构
[1] Minia Univ, Fac Med, Dept Ophthalmol, Al Minya, Egypt
来源
OPEN OPHTHALMOLOGY JOURNAL | 2022年 / 16卷
关键词
Toric implantable collamer lens (T-ICL); Toric implantable phakic contact lens (IPCL); Myopia; Astigmatism; Keratitis; Intraocular pressure; INTRAOCULAR-LENS; OPTICAL-QUALITY; FOLLOW-UP; SAFETY; HOLE; IOL;
D O I
10.2174/18743641-v16-e2204050
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Our study aimed to compare the clinical, visual outcomes, and efficacy of toric Implantable Collamer Lens (T-ICL) and toric implantable phakic contact lens (IPCL) in patients with high myopia and astigmatism over a follow-up period of 6 months. Methods: A prospective interventional randomized comparative study included 60 myopic eyes divided into 2 groups, group A including 30 eyes that were implanted with T-ICL, and group B, including 30 eyes that were implanted with toric IPCL. The refractive results, visual acuity, central corneal endothelial cell count, and intraocular pressure (IOP) were evaluated at baseline and at 1 and 6 months post-surgery. Any complications either during or after surgery were assessed. Results: In both study groups, the mean central corneal endothelial cell count was significantly decreased after 1 month and improved to reach near pre-operative values after 6 months postoperatively, indicating good lens biocompatibility. A statistically significant increase in IOP was found in both groups during the early follow-up, and a significant decrease after 6 months postoperatively (p=0.036) was reported in group A. A significant reduction in both spherical and cylindrical refractive errors with good predictability was reported in both groups compared with pre-operative values. Regarding the predictability, In T-ICL group (A), the median spherical and cylindrical errors were significantly improved from (-10 D & -4.5 D) pre-operatively to (-0.3 D & - 0.3 D) at the end of 6 months follow up period. Similarly, in the toric IPCL group (B), the median spherical and cylindrical errors were significantly improved from (-11 D & -4.5 D) pre-operatively to (-0.3 D & - 0.3 D) by the end of follow up period. A statistically significant improvement of UCDVA at 6 months postoperatively was found in both groups, as median preoperative LogMAR UCDVA was 1.1 and 1.3 in groups A and B respectively, which was improved to 0.3 in both groups at the end of follow-up period. There were no reported intra- or postoperative complications such as cataract, keratitis, or lens decentration. Conclusion: Toric IPCL is a suitable alternative to T-ICL for the management of high myopia with astigmatism, especially in developing countries, as it is cheaper and easier to implant than T-ICL. However, data over longer follow-up periods are needed to confirm its safety and stability.
引用
收藏
页数:8
相关论文
共 46 条
  • [1] Evaluation of the Anterior Chamber Parameters by Pentacam after Toric Implantable Phakic Contact lens (IPCL) Implantation in Moderate to High Myopia with Astigmatism
    Mahmoud, Mohamed Salah El-Din
    Hamid, Mohamed Abdel
    Esmail, Mohamed Esmail Khalil
    Halim, Ahmed Abdel
    OPEN OPHTHALMOLOGY JOURNAL, 2022, 16
  • [2] Evaluation of the toric implantable collamer lens for simultaneous treatment of myopia and astigmatism
    Price, Marianne O.
    Price, Francis W., Jr.
    EXPERT REVIEW OF MEDICAL DEVICES, 2015, 12 (01) : 25 - 39
  • [3] Toric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes
    Mertens, Erik L.
    CLINICAL OPHTHALMOLOGY, 2011, 5 : 369 - 375
  • [4] Toric implantable phakic contact lens versus bioptics for the correction of moderate to high myopia and astigmatism
    Elbakry, Amr A.
    Sobhi, Rania M.
    Hassanein, Ahmed
    El Shiwy, Hoda T.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2023, 116 (01) : 15 - 23
  • [5] Visual outcomes and patient satisfaction after implantable collamer lens and Toric implantable collamer lens correction for moderate to high myopia and myopic astigmatism
    Bamashmus, Mahfouth A.
    Al-Arabi, Ammar H.
    Alawad, Mohammed A.
    SAUDI MEDICAL JOURNAL, 2013, 34 (09) : 913 - 919
  • [6] Correction of Internal Astigmatism Using Toric Scleral Contact Lens after Implantable Collamer Lens Surgery
    Yang, Seung Ahn
    Lee, Ji Eun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (07): : 475 - 479
  • [7] A Case of Squint Correction With Toric Implantable Phakic Contact Lens (IPCL) Implantation: A Novel Approach to High Myopia With Sensory Exotropia
    Gandhi, Shreya
    Paranjpe, Radhika
    Gogate, Parikshit
    Goli, Kalpita B.
    Goyal, Khushboo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [8] Comparison of visual outcomes after non-toric and toric implantable collamer lens V4c for myopia and astigmatism
    Wei, Ruoyan
    Li, Meiyan
    Niu, Lingling
    Aruma, Aruma
    Miao, Huamao
    Shen, Yang
    Yao, Peijun
    Wang, Xiaoying
    Zhang, Huihui
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (05) : 511 - 518
  • [9] Comparison of patient outcomes after implantation of Visian toric implantable collamer lens and iris-fixated toric phakic intraocular lens
    Lee, S. Y.
    Kwon, H. J.
    Ahn, H. S.
    Seo, K. Y.
    Kim, E. K.
    Kim, T-I
    EYE, 2011, 25 (11) : 1409 - 1417
  • [10] Implanting toric implantable collamer lens displays better astigmatism correction than implantable collamer lens combined with manually limbal relaxing incision
    Ke Yang
    Jiaxin Li
    Weihua Zhang
    Zhanjiang Liu
    Chenjie Song
    Yang Zhao
    BMC Ophthalmology, 23