A wireless wearable surface functional electrical stimulator

被引:17
作者
Wang, Hai-Peng [1 ]
Guo, Ai-Wen [1 ]
Zhou, Yu-Xuan [2 ]
Xia, Yang [3 ]
Huang, Jia [3 ]
Xu, Chong-Yao [1 ,5 ]
Huang, Zong-Hao [1 ]
Lu, Xiao-ying [2 ,4 ]
Wang, Zhi-Gong [1 ,4 ]
机构
[1] Southeast Univ, Inst RF & OE ICs, Nanjing, Jiangsu, Peoples R China
[2] Southeast Univ, State Key Lab Bioelect, Nanjing, Jiangsu, Peoples R China
[3] ZhongDa Hosp, Dept Rehabil Med, Nanjing, Jiangsu, Peoples R China
[4] Nantong Univ, Coinnovat Ctr Neuroregenerat, Nantong, Peoples R China
[5] Guangdong Univ Technol, Sch Automat, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Functional electrical stimulation (FES); stimulation circuit; charge-balanced biphasic stimulation; time division multiplexing; wearable device; SYSTEM;
D O I
10.1080/00207217.2017.1312708
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a wireless wearable functional electrical stimulator controlled by Android phone with real-time-varying stimulation parameters for multichannel surface functional electrical stimulation application has been developed. It can help post-stroke patients using more conveniently. This study focuses on the prototype design, including the specific wristband concept, circuits and stimulation pulse-generation algorithm. A novel stimulator circuit with a driving stage using a complementary current source technique is proposed to achieve a high-voltage compliance, a large output impedance and an accurate linear voltage-to-current conversion. The size of the prototype has been significantly decreased to 17x7.5x1cm(3). The performance of the prototype has been tested with a loaded resistor and wrist extension/flexion movement of three hemiplegic patients. According to the experiments, the stimulator can generate four-channel charge-balanced biphasic stimulation with a voltage amplitude up to 60V, and the pulse frequency and width can be adjusted in real time with a range of 100-600s and 20-80Hz, respectively.
引用
收藏
页码:1514 / 1526
页数:13
相关论文
共 22 条
[1]  
Baker L., 2000, NEURO MUSCULAR ELECT, V4th
[2]   Modeling and Control of PV Charger System With SEPIC Converter [J].
Chiang, S. J. ;
Shieh, Hsin-Jang ;
Chen, Ming-Chieh .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) :4344-4353
[3]   DIGITAL ELECTRONIC CONTROLLER FOR ABOVE KNEE LEG PROSTHESES [J].
CHITORE, DS ;
RAHMATALLAH, SF ;
ALBAKRY, KS .
INTERNATIONAL JOURNAL OF ELECTRONICS, 1988, 64 (04) :649-656
[4]  
Farahmand S, 2012, IEEE ENG MED BIO, P6120, DOI 10.1109/EMBC.2012.6347390
[5]  
Farahmand S, 2012, IEEE ENG MED BIO, P863, DOI 10.1109/EMBC.2012.6346068
[6]  
Graf H. B., 2011, 2011 IEEE INT S WORL, P1, DOI [10.1109/WoWMoM.2011.5986386, DOI 10.1109/WOWMOM.2011.5986386]
[7]   STIMULUS WAVE-FORMS FOR SELECTIVE NEURAL STIMULATION [J].
GRILL, WM ;
MORTIMER, JT .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (04) :375-385
[8]  
Honert C.V. D., 1989, U. S. Patent, Patent No. 4856525
[9]   A novel functional electrical stimulation-control system for restoring motor function of post-stroke hemiplegic patients [J].
Huang, Zonghao ;
Wang, Zhigong ;
Lv, Xiaoying ;
Zhou, Yuxuan ;
Wang, Haipeng ;
Zone, Sihao .
NEURAL REGENERATION RESEARCH, 2014, 9 (23) :2102-2110
[10]  
Ijzerman M., 1996, J. Rehabil. Sci, V9, P86