Titanium nanoparticles (TiO2)/ graphene oxide nanosheets (GO): an electrochemical sensing platform for the sensitive and simultaneous determination of benzocaine in the presence of antipyrine

被引:49
作者
Mohamed, Mona A. [1 ]
Atty, Shimaa A. [1 ]
Merey, Hanan A. [2 ]
Fattah, Taghreed A. [1 ]
Foster, Christopher W. [3 ]
Banks, Craig E. [3 ]
机构
[1] NODCAR, Pharmaceut Chem Dept, Giza, Egypt
[2] Cairo Univ, Fac Pharm, Analyt Chem Dept, Cairo, Egypt
[3] Manchester Metropolitan Univ, Fac Sci & Engn, Chester St, Chester M1 5GD, Cheshire, England
关键词
LIQUID-CHROMATOGRAPHY; LOCAL-ANESTHETICS; MASS-SPECTROMETRY; METHEMOGLOBINEMIA; MULTIVARIATE; DEGRADATION; SUBSTANCES; ELECTRODES; PHENAZONE; PRODUCTS;
D O I
10.1039/c7an01101f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An effective electrochemical sensing platform for the simultaneous determination of benzocaine (BEN) and antipyrine (ANT) based upon titanium dioxide nanoparticle (TiO2)/graphene oxide nanosheet (GO) bulk modified carbon paste electrodes (TiO2-GO/CPE) is reported. The TiO2-GO/CPE electrochemical sensing platform is found to exhibit linear ranges from 1.0 x 10(-6) to 1.0 x 10(-4) M and 1.2 x 10(-8) to 8.0 x 10(-5) M for BEN and ANT, respectively. The TiO2-GO/CPE sensor is explored towards the analysis of BEN and ANT in oral fluid (saliva) and pharmaceutical products. The synergy between the graphene oxide nanosheets and titanium dioxide nanoparticles results in a dramatic enhancement in the sensitivity of the sensor through a combination of increased surface area and improved electron transfer kinetics compared to other electrode alternatives. The fabricated TiO2-GO/CPE exhibits high sensitivity and good stability towards the sensing of BEN and ANT and has the potential to be utilised as a clinical assay and QA in pharmaceutical products.
引用
收藏
页码:3674 / 3679
页数:6
相关论文
共 40 条
[1]   Determination of diminazene aceturate in pharmaceutical formulations by HPLC and identification of related substances by LC/MS [J].
Atsriku, C ;
Watson, DG ;
Tettey, JNA ;
Grant, MH ;
Skellern, GG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) :979-986
[2]  
Barbosa-Filho José M., 2006, Rev. bras. farmacogn., V16, P109, DOI 10.1590/S0102-695X2006000100020
[3]  
Brownson D.A. C., 2014, HDB GRAPHENE ELECTRO
[4]  
C. British Pharmacopoeia, 2008, BRIT PHARM 2010
[5]  
C. United States Pharmacopeial, 2012, US PHARM USP 35 NAT
[6]   Titanium dioxide nanomaterials: Synthesis, properties, modifications, and applications [J].
Chen, Xiaobo ;
Mao, Samuel S. .
CHEMICAL REVIEWS, 2007, 107 (07) :2891-2959
[7]   Simultaneous spectrophotometric-multivariate calibration determination of several components of ophthalmic solutions: phenylephrine, chloramphenicol, antipyrine, methylparaben and thimerosal [J].
Collado, MS ;
Mantovani, VE ;
Goicoechea, HC ;
Olivieri, AC .
TALANTA, 2000, 52 (05) :909-920
[8]   High performance liquid chromatography-diode array and electrospray-mass spectrometry analysis of vardenafil, sildenafil, tadalafil, testosterone and local anesthetics in cosmetic creams sold on the Internet web sites [J].
De Orsi, Daniela ;
Pellegrini, Manuela ;
Marchei, Emilia ;
Nebuloni, Paolo ;
Gallinella, Bruno ;
Scaravelli, Giulia ;
Martufi, Alessio ;
Gagliardi, Luigi ;
Pichini, Simona .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (03) :362-369
[9]   Determination of Benzocaine Using HPLC and FIA with Amperometric Detection on a Carbon Paste Electrode [J].
Dejmkova, Hana ;
Vokalova, Veronika ;
Zima, Jiri ;
Barek, Jiri .
ELECTROANALYSIS, 2011, 23 (03) :662-666
[10]  
Dutu G, 2011, FARMACIA, V59, P147