Concentration of heparin-locking solution and risk of central venous hemodialysis catheter malfunction

被引:37
作者
Thomas, Chandra M.
Zhang, Jianguo
Lim, Teik How
Scott-Douglas, Nairne
Hons, Ronald B.
Hemmelgarn, Brenda R.
机构
[1] Univ Calgary, Dept Med, Div Nephrol, Calgary, AB, Canada
[2] Univ Calgary, Dept Community Hlth Sci, Calgary, AB, Canada
关键词
D O I
10.1097/MAT.0b013e3180619519
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heparin is used as an interdialytic locking solution for hemo-dialysis (HD) central venous catheters (CVCs). The purpose of this study was to compare effectiveness of two heparin concentrations (10,000 and 1,000 U/mL) in preventing catheter malfunction. We compared two time periods: a 6-month period with heparin 10,000 U/mL and a 3-month period with heparin 1,000 U/mL. Adults on HD using a CVC (tunneled or untunneled) in Calgary, Alberta, were included. The primary outcome was catheter malfunction. A total of 139 and 134 patients in the heparin 10,000 and 1,000 U/mL periods, respectively, were included. The crude rate of catheter malfunction, per 1,000 HD sessions, was similar for heparin 10,000 (7.6; 95% CI, 5.3 to 10.8) and 1,000 (6.7; 95% CI, 4.3 to 10.3) U/mL periods, respectively (p = 0.76). After adjusting for CVC characteristics and use of recombinant tissue plasminogen activator (rt-PA), there was no association between heparin concentration and CVC malfunction (hazard ratio, 0.77; 95% CI, 0.37 to 1.61). In conclusion, the use of a lower concentration of heparin was not associated with an increased risk of catheter malfunction but may be associated with greater rt-PA use. The association between heparin concentration and rt-PA use requires further study. ASAIO Journal 2007; 53:485-488.
引用
收藏
页码:485 / 488
页数:4
相关论文
共 17 条
[1]   Catheter thrombosis [J].
Beathard, GA .
SEMINARS IN DIALYSIS, 2001, 14 (06) :441-445
[2]   Filling hemodialysis catheters in the interdialytic period: Heparin versus citrate versus polygeline: A prospective randomized study [J].
Buturovic, J ;
Ponikvar, R ;
Kandus, A ;
Boh, M ;
Klinkmann, J ;
Ivanovich, P .
ARTIFICIAL ORGANS, 1998, 22 (11) :945-947
[3]  
*CAN I HLTH INF, 2005, CAN ORG REPL REG REP
[4]   MODEL FOR ASSOCIATION IN BIVARIATE LIFE TABLES AND ITS APPLICATION IN EPIDEMIOLOGICAL-STUDIES OF FAMILIAL TENDENCY IN CHRONIC DISEASE INCIDENCE [J].
CLAYTON, DG .
BIOMETRIKA, 1978, 65 (01) :141-151
[5]  
Hougaard P., 2012, ANAL MULTIVARIATE SU
[6]   Risk of heparin lock-related bleeding when using indwelling venous catheter in haemodialysis [J].
Karaaslan, H ;
Peyronnet, P ;
Benevent, D ;
Lagarde, C ;
Rince, M ;
Leroux-Robert, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (10) :2072-2074
[7]   A longitudinal study of the repeated use of alteplase as therapy for tunneled hemodialysis catheter dysfunction [J].
Little, MA ;
Walshe, JJ .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 39 (01) :86-91
[8]   Establishment and maintenance of vascular access in incident hemodialysis patients: A prospective cost analysis [J].
Manns, B ;
Tonelli, M ;
Yilmaz, S ;
Lee, H ;
Laupland, K ;
Klarenbach, S ;
Radkevich, V ;
Murphy, B .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2005, 16 (01) :201-209
[9]  
Manns BJ, 2001, CLIN INVEST MED, V24, P164
[10]   Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis [J].
Marr, KA ;
Sexton, DJ ;
Conlon, PJ ;
Corey, GR ;
Schwab, SJ ;
Kirkland, KB .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :275-+