Assessment of nose protector for sport activities: finite element analysis

被引:15
作者
Coto, Neide Pena [1 ]
Cruz Meira, Josete Barbosa [1 ]
Brito e Dias, Reinaldo [1 ]
Driemeier, Larissa [2 ]
Roveri, Guilherme de Oliveira [2 ]
Noritomi, Pedro Yoshito [3 ]
机构
[1] Univ Sao Paulo, Fac Odontol, Sao Paulo, Brazil
[2] Univ Sao Paulo, Escola Politecn, Dept Engn Mecatron & Sistemas Mecan, Sao Paulo, Brazil
[3] Ctr Tecnol Informacao Renato Archer, Sao Paulo, Brazil
关键词
MAXILLOFACIAL FRACTURES; OROFACIAL INJURIES; BIOMECHANICS; TRAUMA;
D O I
10.1111/j.1600-9657.2011.01046.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
There has been a significant increase in the number of facial fractures stemming from sport activities in recent years, with the nasal bone one of the most affected structures. Researchers recommend the use of a nose protector, but there is no standardization regarding the material employed. Clinical experience has demonstrated that a combination of a flexible and rigid layer of ethylene vinyl acetate (EVA) offers both comfort and safety to practitioners of sports. The aim of the present study was the investigation into the stresses generated by the impact of a rigid body on the nasal bone on models with and without an EVA protector. For such, finite element analysis was employed. A craniofacial model was constructed from images obtained through computed tomography. The nose protector was modeled with two layers of EVA (1 mm of rigid EVA over 2 mm of flexible EVA), following the geometry of the soft tissue. Finite element analysis was performed using the LS Dyna program. The bone and rigid EVA were represented as elastic linear material, whereas the soft tissues and flexible EVA were represented as hyperelastic material. The impact from a rigid sphere on the frontal region of the face was simulated with a constant velocity of 20 m s-1 for 9.1 mu s. The model without the protector served as the control. The distribution of maximal stress of the facial bones was recorded. The maximal stress on the nasal bone surpassed the breaking limit of 0.130.34 MPa on the model without a protector, while remaining below this limit on the model with the protector. Thus, the nose protector made from both flexible and rigid EVA proved effective at protecting the nasal bones under high-impact conditions.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 30 条
[1]   Sports-related maxillofacial fractures over an 11-year period [J].
Antoun, Josepb S. ;
Lee, Kai H. .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (03) :504-508
[2]  
Bonet J., 1997, NONLINEAR CONTINUUM
[3]   110 SPORTS-RELATED FACIAL FRACTURES [J].
CARROLL, SM ;
JAWAD, MA ;
WEST, M ;
OCONNOR, TPF .
BRITISH JOURNAL OF SPORTS MEDICINE, 1995, 29 (03) :194-195
[4]   Security Hi-tech Individual Extra-Light Device Mask: A new protection for [soccer] players [J].
Cascone, Piero ;
Petrucci, Bernardino ;
Ramieri, Valerio ;
TitoMatteo, Marianetti .
JOURNAL OF CRANIOFACIAL SURGERY, 2008, 19 (03) :772-776
[5]  
Coto N, 2006, INFORM NEWS
[6]  
Coto Neide Pena, 2007, Braz. Dent. J., V18, P324, DOI 10.1590/S0103-64402007000400010
[7]   Maxillofacial fractures sustained during sports played with a ball [J].
Delilbasi, C ;
Yamazawa, M ;
Nomura, K ;
Iida, S ;
Kogo, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (01) :23-27
[8]   Analysis of treatment for isolated zygomaticomaxillary complex fractures [J].
Ellis, E ;
Kittidumkerng, W .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (04) :386-400
[9]  
Ellis E, 1996, J ORAL MAXILLOFAC SU, V54
[10]   Mechanical responses to orthodontic loading: A 3-dimensional finite element multi-tooth model [J].
Field, Clarice ;
Ichim, Ionut ;
Swain, Michael V. ;
Chan, Eugene ;
Darendeliler, M. Ali ;
Li, Wei ;
Lig, Qing .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (02) :174-181