Radiation exposure from CT in early childhood: a French large-scale multicentre study

被引:79
作者
Bernier, M-O [1 ]
Rehel, J-L [2 ]
Brisse, H. J. [3 ,4 ]
Wu-Zhou, X.
Caer-Lorho, S.
Jacob, S.
Chateil, J. F. [4 ,5 ]
Aubert, B. [2 ]
Laurier, D.
机构
[1] Inst Radioprotect & Surete Nucl, Lab Epidemiol, IRSN DRPH SRBE LEPID, Dept Epidemiol, F-92262 Fontenay Aux Roses, France
[2] Inst Radioprotect & Surete Nucl, Med Radiat Protect Expertise Unit, F-92262 Fontenay Aux Roses, France
[3] Inst Curie, Dept Radiol, Paris, France
[4] Grp Hosp Pellegrin, Soc Francophone Imagerie Pediat & Prenatale, Bordeaux, France
[5] Grp Hosp Pellegrin, Dept Radiol, Bordeaux, France
关键词
ANTHROPOMORPHIC PHANTOM; DOSE ESTIMATION; PEDIATRIC CT; ROW CT; CHILDREN; CANCER; ORGAN; RISK; RAY; POPULATION;
D O I
10.1259/bjr/90758403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The increasing use of CT scans in the paediatric population raises the question of a possible health impact of ionising radiation exposure associated with CT scans. The aim of this study was to describe the pattern of CT use in early childhood. Methods: In 14 major French paediatric radiology departments, children undergoing at least 1 CT scan before age 5, between 2000 and 2006, were included. For each examination, absorbed organ doses were calculated. Results: 43% of the 27 362 children in the cohort were aged less than 1 year during their first exposure, with 9% being aged less than 1 month. The mean number of examinations per child was 1.6 (range 1-43). The examinations included: head in 63% of the cases, chest in 21%, abdomen and pelvis in 8% and others in 8%. Brain and eye lenses received the highest cumulative doses from head examinations, with mean organ dose values of 22 mGy (maximum 1107 mGy) and 26 mGy (maximum 1392 mGy), respectively. The mean cumulative effective dose was 3.2 mSv (range 0.1-189 mSv). Conclusion: CT scan exposure in childhood is responsible for relatively high doses to radiosensitive organs. The rather large dose range according to the protocols used requires their optimisation. The cohort follow-up will study the risk of long-term radiation-induced cancer.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 36 条
[1]   Radiation doses to neonates during X ray computed tomography examinations [J].
Akahane, K ;
Hashimoto, M ;
Hada, M ;
Takano, Y ;
Ono, K ;
Kai, M ;
Kusama, T .
RADIATION PROTECTION DOSIMETRY, 2003, 103 (01) :41-45
[2]   Radiation dose to the eyes and parotids during CT of the sinuses [J].
Bassim, MK ;
Ebert, CS ;
Sit, RC ;
Senior, BA .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2005, 133 (04) :531-533
[3]   Incidence of cancer in children perinatally exposed to nucleoside reverse transcriptase inhibitors [J].
Benhammou, Valerie ;
Warszawski, Josiane ;
Bellec, Stephanie ;
Doz, Francois ;
Andre, Nicolas ;
Lacour, Brigitte ;
Levine, Martine ;
Bavoux, Francoise ;
Tubiana, Roland ;
Mandelbrot, Laurent ;
Clavel, Jacqueline ;
Blanche, Stephane .
AIDS, 2008, 22 (16) :2165-2177
[4]   French population exposure to radon, terrestrial gamma and cosmic rays [J].
Billon, S ;
Morin, A ;
Caër, S ;
Baysson, H ;
Gambard, JP ;
Backe, JC ;
Rannou, A ;
Tirmarche, M ;
Laurier, D .
RADIATION PROTECTION DOSIMETRY, 2005, 113 (03) :314-320
[5]   PRENATAL IRRADIATION AND CHILDHOOD MALIGNANCY - REVIEW OF BRITISH DATA FROM OXFORD SURVEY [J].
BITHELL, JF ;
STEWART, AM .
BRITISH JOURNAL OF CANCER, 1975, 31 (03) :271-287
[6]   DIAGNOSTIC-X-RAY PROCEDURES AND RISK OF LEUKEMIA, LYMPHOMA, AND MULTIPLE-MYELOMA [J].
BOICE, JD ;
MORIN, MM ;
GLASS, AG ;
FRIEDMAN, GD ;
STOVALL, M ;
HOOVER, RN ;
FRAUMENI, JF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (10) :1290-1294
[7]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[8]   CT exposure from pediatric MDCT: results from the 2007-2008 SFIPP/ISRN survey [J].
Brisse, H. J. ;
Aubert, B. .
JOURNAL DE RADIOLOGIE, 2009, 90 (02) :207-215
[9]   ASSESSMENT OF ORGAN ABSORBED DOSES AND ESTIMATION OF EFFECTIVE DOSES FROM PEDIATRIC ANTHROPOMORPHIC PHANTOM MEASUREMENTS FOR MULTI-DETECTOR ROW CT WITH AND WITHOUT AUTOMATIC EXPOSURE CONTROL [J].
Brisse, Herve J. ;
Robilliard, Magalie ;
Savignoni, Alexia ;
Pierrat, Noelle ;
Gaboriaud, Genevieve ;
De Rycke, Yann ;
Neuenschwander, Sylvia ;
Aubert, Bernard ;
Rosenwald, Jean-Claude .
HEALTH PHYSICS, 2009, 97 (04) :303-314
[10]   Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study [J].
Brix, G ;
Lechel, U ;
Veit, R ;
Truckenbrodt, R ;
Stamm, G ;
Coppenrath, EM ;
Griebel, J ;
Nagel, HD .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1275-1284