The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study

被引:300
作者
Duyck, J
Ronold, HJ
Van Oosterwyck, H
Naert, I
Sloten, JV
Ellingsen, JE
机构
[1] Univ Oslo, Dept Prosthet Dent, Oral Res Lab, N-0317 Oslo, Norway
[2] Catholic Univ, Dept Prosthet Dent, BIOMAT Res Grp, Louvain, Belgium
[3] Catholic Univ, Dept Mech, Div Biomech & Engn Design, Louvain, Belgium
关键词
oral implants; biomechanics; rabbit tibia; static loading; dynamic loading; bone response;
D O I
10.1034/j.1600-0501.2001.012003207.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Although it is generally accepted that adverse forces can impair osseointegration, the mechanism of this complication is unknown. In this study, static and dynamic loads were applied on 10 mm long implants (Branemark System((R)), Nobel Biocare, Sweden) installed bicortically in rabbit tibiae to investigate the bone response. Each of 10 adult New Zealand black rabbits had one statically loaded implant (with a transverse force of 29.4 N applied on a distance of 1.5 mm from the top of the implant, resulting in a bending moment of 4.4 Ncm), one dynamically loaded implant (with a transverse force of 14.7 N applied on a distance of 50 mm from the top of the implant, resulting in a bending moment of 73.5 Ncm, 2.520 cycles in total, applied with a frequency of 1 Hz), and one unloaded control implant. The loading was performed during 14 days. A numerical model was used as a guideline for the applied dynamic load. Histomorphometrical quantifications of the bone to metal contact area and bone density lateral to the implant were performed on undecalcified and toluidine blue stained sections. The histological picture was similar for statically loaded and control implants. Dense cortical lamellar bone was present around the marginal and apical part of the latter implants with no signs of bone loss. Crater-shaped bone defects and Howship's lacunae were explicit signs of bone resorption in the marginal bone area around the dynamically loaded implants. Despite those bone defects, bone islands were present in contact with the implant surface in this marginal area. This resulted in no significantly lower bone-to-implant contact around the dynamically loaded implants in comparison with the statically loaded and the control implants. However, when comparing the amount of bone in the immediate surroundings of the marginal part of the implants, significantly (P <0.007) less bone volume (density) was present around the dynamically loaded in comparison with the statically loaded and the control implants. This study shows that excessive dynamic loads cause crater-like bone defects lateral to osseointegrated implants.
引用
收藏
页码:207 / 218
页数:12
相关论文
共 52 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]   Reactions of peri-implant tissues to continuous loading of osseointegrated implants [J].
Akin-Nergiz, N ;
Nergiz, I ;
Schulz, A ;
Arpak, N ;
Niedermeier, W .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (03) :292-298
[3]   A MULTICENTER REPORT ON OSSEOINTEGRATED ORAL IMPLANTS [J].
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1988, 60 (01) :75-84
[4]   A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE [J].
ASHMAN, RB ;
COWIN, SC ;
VANBUSKIRK, WC ;
RICE, JC .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :349-361
[5]   Quantification of periapical bone destruction in mice by micro-computed tomography [J].
Balto, K ;
Müller, R ;
Carrington, DC ;
Dobeck, J ;
Stashenko, P .
JOURNAL OF DENTAL RESEARCH, 2000, 79 (01) :35-40
[6]   BONE REMODELING IN RESPONSE TO INVIVO FATIGUE MICRODAMAGE [J].
BURR, DB ;
MARTIN, RB ;
SCHAFFLER, MB ;
RADIN, EL .
JOURNAL OF BIOMECHANICS, 1985, 18 (03) :189-&
[7]  
CARLSSON LV, 1989, THESIS GOTEBORG SWED
[8]  
Carr A B, 1993, J Prosthodont, V2, P2, DOI 10.1111/j.1532-849X.1993.tb00373.x
[9]  
Carr A B, 1996, Int J Oral Maxillofac Implants, V11, P589
[10]   The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit [J].
Carr, AB ;
Gerard, DA ;
Larsen, PE .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (05) :500-509