Dynamic gadolinium-enhanced MR imaging of pituitary adenomas: usefulness of sequential sagittal and coronal plane images

被引:30
作者
Gao, RH [1 ]
Isoda, H [1 ]
Tanaka, T [1 ]
Inagawa, S [1 ]
Takeda, H [1 ]
Takehara, Y [1 ]
Isogai, S [1 ]
Sakahara, H [1 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Radiol, Hamamatsu, Shizuoka 4313192, Japan
关键词
magnetic resonance imaging; contrast media; dynamic MR imaging; pituitary adenoma;
D O I
10.1016/S0720-048X(01)00354-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic magnetic resonance (MR) imaging for pituitary adenomas is usually performed in a coronal direction; however, small lesions between slices, or lesions located at the anterior or posterior aspect of the pituitary gland might be overlooked on MR images in only the coronal direction. The purpose of our study was to evaluate whether consecutive dynamic MR images in the coronal and sagittal planes improve detection of pituitary adenomas. Eighteen patients with pituitary microadenomas and nine with healthy pituitary glands were included in this study. MR images were performed with 1.5 T superconductive units and commercially-available head coils. After a 5 ml gadolinium contrast injection, eight serial dynamic sagittal images were obtained. Within 3 or 6 min, this was followed by a 10-15 ml gadolinium injection and acquisition of eight serial dynamic coronal images. Dynamic MR images and conventional noncontrast- and contrast-enhanced sagittal and coronal T1-weighted images were evaluated independently in a blind fashion by two neuroradiologists regarding the depiction of pituitary microadenomas. The sensitivities of dynamic enhanced MR imaging in the detection of microadenomas were 61.1% in sagittal direction, 72.2% in coronal direction respectively, and were superior to those of conventional noncontrast- and contrast-enhanced T1-weighted imaging (22.2-50%). The sensitivity of a combination of sagittal and coronal dynamic enhanced MR imaging for the detection of microadenomas was 88.9% and was superior to those of conventional noncontrast- and contrast-enhanced T1-weighted imaging combining sagittal and coronal directions (61.1%, 61.1%) (P<0.05, P<0.05, respectively). The specificity and accuracy of dynamic enhanced MR imaging with combination of sagittal and coronal images was 88.9% respectively. Dynamic gadolinium-enhanced MR imaging, especially using both sagittal and coronal planes, was concluded to be useful for the detection of pituitary microadenomas. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 13 条
[1]  
Bartynski WS, 1997, AM J NEURORADIOL, V18, P965
[2]   PITUITARY MICROADENOMAS - EARLY ENHANCEMENT WITH DYNAMIC CT - IMPLICATIONS OF ARTERIAL BLOOD-SUPPLY AND POTENTIAL IMPORTANCE [J].
BONNEVILLE, JF ;
CATTIN, F ;
GORCZYCA, W ;
HARDY, J .
RADIOLOGY, 1993, 187 (03) :857-861
[3]  
COLOMBO N, 1994, AM J NEURORADIOL, V15, P1591
[4]   PITUITARY-ADENOMA - CORRELATION OF HALF-DOSE GADOLINIUM-ENHANCED MR IMAGING WITH SURGICAL FINDINGS IN 26 PATIENTS [J].
DAVIS, PC ;
GOKHALE, KA ;
JOSEPH, GJ ;
PETERMAN, SB ;
ADAMS, DA ;
TINDALL, GT ;
HUDGINS, PA ;
HOFFMAN, JC .
RADIOLOGY, 1991, 180 (03) :779-784
[5]   VARIED MICROCIRCULATION OF PITUITARY-ADENOMAS AT RAPID, DYNAMIC, CONTRAST-ENHANCED MR-IMAGING [J].
FINELLI, DA ;
KAUFMAN, B .
RADIOLOGY, 1993, 189 (01) :205-210
[6]   CHEMICAL-SHIFT SELECTIVE MR IMAGING USING A WHOLE-BODY MAGNET [J].
FRAHM, J ;
HAASE, A ;
HANICKE, W ;
MATTHAEI, D ;
BOMSDORF, H ;
HELZEL, T .
RADIOLOGY, 1985, 156 (02) :441-444
[7]   DETECTION OF PITUITARY MICROADENOMAS - COMPARISON OF DYNAMIC KEYHOLE FAST SPIN-ECHO, UNENHANCED, AND CONVENTIONAL CONTRAST-ENHANCED MR-IMAGING [J].
KUCHARCZYK, W ;
BISHOP, JE ;
PLEWES, DB ;
KELLER, MA ;
GEORGE, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :671-679
[8]   PITUITARY-ADENOMAS AND NORMAL PITUITARY TISSUE - ENHANCEMENT PATTERNS ON GADOPENTETATE-ENHANCED MR IMAGING [J].
MIKI, Y ;
MATSUO, M ;
NISHIZAWA, S ;
KURODA, Y ;
KEYAKI, A ;
MAKITA, Y ;
KAWAMURA, J .
RADIOLOGY, 1990, 177 (01) :35-38
[9]   NORMAL AND ABNORMAL PITUITARY-GLANDS - GADOPENTETATE DIMEGLUMINE-ENHANCED MR IMAGING [J].
SAKAMOTO, Y ;
TAKAHASHI, M ;
KOROGI, Y ;
BUSSAKA, H ;
USHIO, Y .
RADIOLOGY, 1991, 178 (02) :441-445
[10]   PITUITARY MICROADENOMAS - DIAGNOSIS WITH 2-DIMENSIONAL AND 3-DIMENSIONAL MR IMAGING AT 1.5 T BEFORE AND AFTER INJECTION OF GADOLINIUM [J].
STADNIK, T ;
STEVENAERT, A ;
BECKERS, A ;
LUYPAERT, R ;
BUISSERET, T ;
OSTEAUX, M .
RADIOLOGY, 1990, 176 (02) :419-428