Background Periprosthetic joint infection (PJI) is one of the most serious complications following total knee arthroplasty (TKA). However, the diagnosis remains a challenge for clinicians. In 2011, the muscoskeletal infection society (MSIS) criteria provided a consensus which has been updated in 2013, but these criteria are complex and contain tests that are time-consuming. The same is applicable to the pro-Implant guidelines. Therefore, a simpler diagnostic test is desirable. Objectives The value of neutrophil gelatinase-associated lipocalin (NGAL), leucocyte esterase (LE) levels, and the white blood cell (WBC) count in synovial fluid to diagnose PJI after TKA was evaluated. Methods In a retrospective cohort study, we analyzed 89 synovial fluid samples from 86 patients with suspected PJI after TKA. Thirteen and 23 of those samples were classified as PJI according to the MSIS and pro-Implant criteria, respectively. Subsequently, NGAL, LE levels, and the WBC count were determined, the former one using an immunoassay. Using either the MSIS or pro-Implant criteria as the golden standard for PJI, sensitivity and specificity of those markers were determined with ROC curves, and medians were compared with Mann-Whitney U and Pearson Chi-square tests. Results When applying the MSIS criteria, NGAL revealed 92% sensitivity and 83% specificity. WBC count showed similar sensitivity (92%) and specificity (84%), whereas sensitivity and specificity for LE were 39% and 88% respectively. When applying the pro-Implant criteria, sensitivity was 95% and specificity was 95% for NGAL. Sensitivity and specificity for WBC count were 100% and 97% and for LE 39% and 92% respectively. Conclusion NGAL and WBC count in synovial fluid has high accuracy in the diagnosis of PJI after TKA and should seriously be considered as part of PJI diagnostics. Leucocyte esterase can serve as rule-in criterion peroperatively. These conclusions are independent of which criteria set was used as golden standard.
引用
收藏
页码:941 / 947
页数:7
相关论文
共 21 条
[1]   Diagnostic accuracy of synovial fluid, blood markers, and microbiological testing in chronic knee prosthetic infections [J].
Balato, Giovanni ;
Franceschini, Vincenzo ;
Ascione, Tiziana ;
Lamberti, Alfredo ;
Balboni, Fiamma ;
Baldini, Andrea .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (02) :165-171
[2]   Inflammatory Blood Laboratory Levels as Markers of Prosthetic Joint Infection A Systematic Review and Meta-Analysis [J].
Berbari, Elie ;
Mabry, Tad ;
Tsaras, Geoffrey ;
Spangehl, Mark ;
Erwin, Pat J. ;
Murad, Mohammad Hassan ;
Steckelberg, James ;
Osmon, Douglas .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (11) :2102-2109
[3]   Periprosthetic infection is the major indication for TKA revision - experiences from a university referral arthroplasty center [J].
Boelch, S. P. ;
Jakuscheit, A. ;
Doerries, S. ;
Fraissler, L. ;
Hoberg, M. ;
Arnholdt, J. ;
Rudert, M. .
BMC MUSCULOSKELETAL DISORDERS, 2018, 19
[4]   Diagnosing Periprosthetic Joint Infection: Has the Era of the Biomarker Arrived? [J].
Deirmengian, Carl ;
Kardos, Keith ;
Kilmartin, Patrick ;
Cameron, Alexander ;
Schiller, Kevin ;
Parvizi, Javad .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (11) :3254-3262
[5]   Synovial Fluid Biomarkers for Periprosthetic Infection [J].
Deirmengian, Carl ;
Hallab, Nadim ;
Tarabishy, Abdul ;
Della Valle, Craig ;
Jacobs, Joshua J. ;
Lonner, Jess ;
Booth, Robert E., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (08) :2017-2023
[6]   Preoperative PCR analysis of synovial fluid has limited value for the diagnosis of periprosthetic joint infections of total knee arthroplasties [J].
Fink, Bernd ;
Steurer, Markus ;
Hofaecker, Sigrid ;
Schaefer, Peter ;
Sandow, Dieter ;
Schuster, Philipp ;
Oremek, Damian .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (06) :871-878
[7]  
Lee YS, 2017, J BONE JOINT SURG AM, V99, P2077, DOI [10.2106/jbjs.17.00123, 10.2106/JBJS.17.00123]
[8]   Iron at the interface of immunity and infection [J].
Nairz, Manfred ;
Haschka, David ;
Demetz, Egon ;
Weiss, Guenter .
FRONTIERS IN PHARMACOLOGY, 2014, 5
[9]   Proceedings of the International Consensus on Periprosthetic Joint Infection [J].
Parvizi, J. ;
Gehrke, T. ;
Chen, A. F. .
BONE & JOINT JOURNAL, 2013, 95B (11) :1450-1452
[10]   Definition of Periprosthetic Joint Infection: Is There a Consensus? [J].
Parvizi, Javad ;
Jacovides, Christina ;
Zmistowski, Benjamin ;
Jung, Kwang Am .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (11) :3022-3030