Multiplexed sensing techniques for cardiovascular disease biomarkers- A review

被引:60
作者
Mani, Veerappan [1 ]
Durmus, Ceren [1 ]
Khushaim, Walaa [1 ]
Ferreira, Daisy Camargo [1 ]
Timur, Suna [2 ,3 ]
Arduini, Fabiana [4 ,5 ]
Salama, Khaled Nabil [1 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Adv Membranes & Porous Mat Ctr, Comp Elect & Math Sci & Engn Div, Sensors Lab, Thuwal 239556900, Saudi Arabia
[2] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Izmir, Turkey
[3] Ege Univ, Cent Res Test & Anal Lab Applicat & Res Ctr, TR-35100 Bornova, Izmir, Turkey
[4] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci, I-00133 Rome, Italy
[5] SENSE4MED, Via Bitonto 139, I-00133 Rome, Italy
关键词
Multiplexed; Simultaneous detection; Cardiovascular disease; Multiple biomarker panel; Myocardial infarction; Immunoassay; Cardiac troponin; C-REACTIVE PROTEIN; ACUTE MYOCARDIAL-INFARCTION; ACID-BINDING PROTEIN; CARDIAC TROPONIN-I; LATERAL FLOW ASSAY; EARLY-DIAGNOSIS; NATRIURETIC PEPTIDE; ELECTROCHEMICAL IMMUNOASSAY; HUMAN SERUM; MARKERS;
D O I
10.1016/j.bios.2022.114680
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Cardiovascular diseases (CVDs) are the number one cause of death worldwide, taking 17.9 million lives each year. The rapid, sensitive, and accurate determination of cardiac biomarkers is vital for the timely diagnosis of CVDs. For accurate diagnosis, dependence on a single biomarker is unreliable because each one has also been linked to other diseases. To overcome this problem, the multiplexed determination of two or more markers has emerged as a promising alternative to single-marker analysis. Over the last 5 years, research interest in the development of biosensors for targeting multiple cardiac markers has increased. In this study, we critically reviewed the various multiplexed biosensing approaches reported during the last 5 years, categorizing them by signal readouts. Prospective detection configurations, capture probes, electrode design strategies, electrode types, nanomaterials, reporter tags, and assay types were reviewed, tabulated, and critically discussed. Then, their advantages and limitations were highlighted. For each category, we provided our perspective as well as the overall critical discussion. Lastly, we summarized potential commercial multiplexed cardiac biosensors and commented on the challenges and future prospects for such sensors.
引用
收藏
页数:16
相关论文
共 78 条
[1]  
[Anonymous], 2011, Cardiovascular disease
[2]   Electrochemical paper-based devices: When the simple replacement of the support to print ecodesigned electrodes radically improves the features of the electrochemical devices [J].
Arduini, Fabiana .
CURRENT OPINION IN ELECTROCHEMISTRY, 2022, 35
[3]   Electrochemical biosensors based on nanomodified screen-printed electrodes: Recent applications in clinical analysis [J].
Arduini, Fabiana ;
Micheli, Laura ;
Moscone, Danila ;
Palleschi, Giuseppe ;
Piermarini, Silvia ;
Ricci, Francesco ;
Volpe, Giulia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :114-126
[4]   Nanomaterial-based aptasensors as an efficient substitute for cardiovascular disease diagnosis: Future of smart biosensors [J].
Azzouz, Abdelmonaim ;
Hejji, Lamia ;
Sonne, Christian ;
Kim, Ki-Hyun ;
Kumar, Vanish .
BIOSENSORS & BIOELECTRONICS, 2021, 193
[5]   Recent progress on the sensitive detection of cardiovascular disease markers by electrochemical-based biosensors [J].
Bakirhan, Nurgul K. ;
Ozcelikay, Goksu ;
Ozkan, Sibel A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 159 :406-424
[6]   Electrochemical paper-based analytical device for multiplexed, point-of-care detection of cardiovascular disease biomarkers [J].
Boonkaew, Suchanat ;
Jang, Ilhoon ;
Noviana, Eka ;
Siangproh, Weena ;
Chailapakul, Orawon ;
Henry, Charles S. .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 330
[7]   Development of a Lateral Flow Highway: Ultra-Rapid Multitracking Immunosensor for Cardiac Markers [J].
Byzova, Nadezhda A. ;
Vengerov, Yuri Yu. ;
Voloshchuk, Sergey G. ;
Zherdev, Anatoly V. ;
Dzantiev, Boris B. .
SENSORS, 2019, 19 (24)
[8]   A triple immunochromatographic test for simultaneous determination of cardiac troponin I, fatty acid binding protein, and C-reactive protein biomarkers [J].
Byzova, Nadezhda A. ;
Zherdev, Anatoly V. ;
Vengerov, Yury Yu. ;
Starovoitova, Tatyana A. ;
Dzantiev, Boris B. .
MICROCHIMICA ACTA, 2017, 184 (02) :463-471
[9]   A potentiometric resolved photoelectrochemical system based on CdS nanowires and SnNb2O6 nanosheets: a case application for dual biomarker analysis [J].
Cao, Jun-Tao ;
Ma, Yan ;
Lv, Jing-Lu ;
Ren, Shu-Wei ;
Liu, Yan-Ming .
CHEMICAL COMMUNICATIONS, 2020, 56 (10) :1513-1516
[10]   Nanomaterials and paper-based electrochemical devices: merging strategies for fostering sustainable detection of biomarkers [J].
Caratelli, Veronica ;
Di Meo, Erika ;
Colozza, Noemi ;
Fabiani, Laura ;
Fiore, Luca ;
Moscone, Danila ;
Arduini, Fabiana .
JOURNAL OF MATERIALS CHEMISTRY B, 2022, 10 (44) :9021-9039