Deconvolution of overlapped peaks based on the exponentially modified Gaussian model in comprehensive two-dimensional gas chromatography

被引:31
作者
Kong, HW [1 ]
Ye, F [1 ]
Lu, X [1 ]
Guo, L [1 ]
Tian, J [1 ]
Xu, GW [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116023, Peoples R China
关键词
gas chromatography; comprehensive two-dimensional gas chromatography; EMG; curve fitting; overlapped peak; deconvolution;
D O I
10.1016/j.chroma.2005.05.103
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional gas chromatography (GC x GC) has attracted much attention for the analys is of complex samples. Even with a large peak capacity in GC x GC, peak overlapping is often met. In this paper, a new method was developed to resolve overlapped peaks based on the mass conservation and the exponentially modified Gaussian (EMG) model. Linear relationships between the calculated sigma, tau of primary peaks with the corresponding retention time (t(R)) were obtained, and the correlation coefficients were over 0.99. Based on such relationships, the elution profile of each compound in overlapped peaks could be simulated, even for the peak never separated on the second-dimension. The proposed method has proven to offer more accurate peak area than the general data processing method. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 25 条
[1]   GRAPHICAL-METHOD FOR OBTAINING RETENTION TIME AND NUMBER OF THEORETICAL PLATES FROM TAILED CHROMATOGRAPHIC PEAKS [J].
BARBER, WE ;
CARR, PW .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1939-1942
[2]   Moving cryogenic modulator for the comprehensive two-dimensional gas chromatography (GC x GC) of surface water contaminants [J].
Beens, J ;
Dallüge, J ;
Adahchour, M ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (03) :134-140
[3]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[4]   Comprehensive two dimensional high-speed gas chromatography with chemometric analysis [J].
Bruckner, CA ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2796-2804
[5]   Comprehensive two-dimensional gas chromatograpy with time-of-flight mass spectrometric detection applied to the determination of pesticides in food extracts [J].
Dallüge, J ;
van Rijn, M ;
Beens, J ;
Vreuls, RJJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :207-217
[6]   Comprehensive two-dimensional gas chromatography:: a powerful and versatile analytical tool [J].
Dallüge, J ;
Beens, J ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :69-108
[7]   Objective data alignment and chemometric analysis of comprehensive two-dimensional separations with run-to-run peak shifting on both dimensions [J].
Fraga, CG ;
Prazen, BJ ;
Synovec, RE .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5833-5840
[8]   CHARACTERIZATION OF EXPONENTIALLY MODIFIED GAUSSIAN PEAKS IN CHROMATOGRAPHY [J].
GRUSHKA, E .
ANALYTICAL CHEMISTRY, 1972, 44 (11) :1733-&
[9]   Determination of sulfur-containing compounds in diesel oils by comprehensive two-dimensional gas chromatography with a sulfur chemiluminescence detector [J].
Hua, RX ;
Li, YY ;
Liu, W ;
Zheng, JC ;
Wei, HB ;
Wang, JH ;
Lu, X ;
Kong, HW ;
Xu, GW .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) :101-109
[10]  
Johnson KJ, 2002, J SEP SCI, V25, P297, DOI 10.1002/1615-9314(20020401)25:5/6<297::AID-JSSC297>3.0.CO