The rigid nasendoscope as a tool for difficult tracheal intubation: A manikin study

被引:5
作者
Goodwin, N
Latto, IP
Hodzovic, I
Williams, G
Hall, JE
机构
[1] Univ Wales Coll Med, Dept Anaesthet, Cardiff CF14 4XN, S Glam, Wales
[2] Univ Wales Hosp, Cardiff CF4 4XW, S Glam, Wales
关键词
equipment; gum elastic bougie; nasendoscope; intubation; tracheal; GUM-ELASTIC BOUGIE; VIDEO CAMERA; STYLET; MANAGEMENT;
D O I
10.1046/j.1365-2044.2003.03203.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We examined the use of the 30degrees rigid nasendoscope in aiding difficult tracheal intubations. A Cormack and Lehane grade 4 difficult intubation (no view of glottis or epiglottis) was set up on a manikin. After 10 s of tuition, 40 anaesthetists attempted to pass a standard gum elastic bougie between the cords, with and without the nasendoscope, in randomised order. A bougie curved to an 'optimal curve' was also tested. Using the standard bougie 13/40 (33%) passed the bougie between the cords without the nasendoscope, compared with 31/40 (78%) when using the nasendoscope (p<0.001). The 'optimal curve' bougie resulted in 29/40 (73%) and 39/40 (98%) success rates without and with the nasendoscope, respectively (p=0.004). The nasendoscope is a simple and easy to use tool in grade 4 intubation, and results are improved further by the use of an 'optimal curve' bougie.
引用
收藏
页码:675 / 679
页数:5
相关论文
共 17 条
[1]   Nasendoscopy: a useful addition to the anaesthetist's armamentarium [J].
Appadurai, IR ;
Davies, JS .
ANAESTHESIA, 2000, 55 (06) :599-600
[2]   Comparison of two video-assisted techniques for the difficult intubation [J].
Biro, P ;
Weiss, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (06) :761-765
[3]   Comparison of a new video-optical intubation stylet versus the conventional malleable stylet in simulated difficult tracheal intubation [J].
Biro, P ;
Weiss, M ;
Gerber, A ;
Pasch, T .
ANAESTHESIA, 2000, 55 (09) :886-889
[4]  
CHUI JW, 2000, ANN ACAD MED SINGAP, V29, P47
[5]   DIFFICULT TRACHEAL INTUBATION IN OBSTETRICS [J].
CORMACK, RS ;
LEHANE, J .
ANAESTHESIA, 1984, 39 (11) :1105-1111
[6]   RAPIDITY AND ACCURACY OF TRACHEAL INTUBATION IN A MANNEQUIN - COMPARISON OF THE FIBEROPTIC WITH THE BULLARD LARYNGOSCOPE [J].
DYSON, A ;
HARRIS, J ;
BHATIA, K .
BRITISH JOURNAL OF ANAESTHESIA, 1990, 65 (02) :268-270
[7]   MORTALITY ASSOCIATED WITH ANESTHESIA - A CASE REVIEW STUDY [J].
GANNON, K .
ANAESTHESIA, 1991, 46 (11) :962-966
[8]   Simulated difficult intubation - Comparison of the gum elastic bougie and the stylet [J].
Gataure, PS ;
Vaughan, RS ;
Latto, IP .
ANAESTHESIA, 1996, 51 (10) :935-938
[9]   A randomised trial of flexible versus rigid nasendoscopy in outpatient sinonasal examination [J].
Midwinter, KI ;
Ahmed, A ;
Willatt, D .
CLINICAL OTOLARYNGOLOGY, 2001, 26 (04) :281-283
[10]   Rigid nasendoscope with video camera system for intubation in infants with Pierre-Robin sequence [J].
Ravishankar, M ;
Kundra, P ;
Agrawal, K ;
Kutralam, NS ;
Arun, N ;
Vijaykumar, OP .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (05) :728-731