A Multi-Channel Electrochemical Measurement System for Biomolecular Detection

被引:1
|
作者
Liu, Wei-Chiun [1 ]
Liu, Bin-Da [1 ]
Wei, Chia-Ling [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan, Taiwan
来源
IEICE TRANSACTIONS ON ELECTRONICS | 2016年 / E99C卷 / 11期
关键词
3-hydroxyanthranilic acid; electrochemical; melatonin; molecularly imprinted polymers; nuclear matrix protein 22; SENSOR ARRAY; CANCER; POTENTIOSTAT; PROTEINS; BLADDER; HEALTH; NMP22; RISK;
D O I
10.1587/transele.E99.C.1295
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A modularized, low-cost, and non-invasive electrochemical examination platform is proposed in this work. Melatonin has been found to be a possible significant indicator molecule in the detection of breast cancer. 3-hydroxyanthranilic acid and nuclear matrix protein 22 can be used as a significant index for potential bladder cancer risks. The proposed system was verified by measuring the melatonin, 3-hydroxyanthranilic acid and nuclear matrix protein 22. Cyclic voltammetry and molecularly imprinted polymers were used in the experiments. Screen-printed electrodes were coated with a film imprinted with target molecules. The measurement results of the proposed system were compared with those of a commercial potentiostat. The two sets of results were very similar. Moreover, the proposed system can be expanded to a four-channel system, which can perform four measurements simultaneously. The proposed system also provides convenient graphical user interface for real-time monitoring and records the information of the redox reactions.
引用
收藏
页码:1295 / 1303
页数:9
相关论文
共 50 条
  • [1] Multi-channel electrochemical detection system based on LabVIEW
    Li, HQ
    Luo, XB
    Liu, CX
    Jiang, LY
    Cui, DF
    Cai, XX
    Yang, QD
    ICIA 2004: Proceedings of 2004 International Conference on Information Acquisition, 2004, : 224 - 227
  • [2] Measurement of isoflavones using liquid chromatography with multi-channel coulometric electrochemical detection
    Ouchi, K
    Gamache, P
    Acworth, I
    Watanabe, S
    BIOFACTORS, 2004, 22 (1-4) : 353 - 356
  • [3] UNIQUE CHANNEL DETECTION IN A MULTI-CHANNEL SYSTEM
    MARINO, PF
    SIAM REVIEW, 1963, 5 (01) : 93 - &
  • [4] Analysis of the Performance of Multi-channel Measurement System
    Li Yu-wei
    Liu Ya
    Li Xiao-hui
    6TH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2010, 7544
  • [5] Measurement of bisphenol A in human urine using liquid chromatography with multi-channel coulometric electrochemical detection
    Ouchi, K
    Watanabe, S
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02): : 365 - 370
  • [6] A new dual-electrode and multi-channel electrochemical detection system for capillary electrophoresis
    Yang, BY
    Mo, JY
    Lai, R
    CHINESE CHEMICAL LETTERS, 2004, 15 (04) : 439 - 442
  • [8] Analysis of overlapped chromatographic peaks by multi-channel electrochemical detection
    Cao, GM
    Hoshino, T
    JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) : 151 - 156
  • [9] Analysis of overlapped chromatographic peaks by multi-channel electrochemical detection
    Pharmaceutical Institute, School of Medicine, Keio University, 35 Shinano-Machi, Hinjuku-Ku, Tokyo 160, Japan
    J. Chromatogr. A, 1-2 (151-156):
  • [10] A MULTI-CHANNEL SYSTEM FOR THE MEASUREMENT OF SPERMATOZOAN COLLECTIVE MOTILITY
    MAYEVSKY, A
    BARSAGIE, D
    BARTOOV, B
    INTERNATIONAL JOURNAL OF ANDROLOGY, 1980, 3 (04): : 436 - 446