Diagnostic accuracy of dual-time-point 18F-FDG PET/CT for the detection of axillary lymph node metastases in breast cancer patients

被引:19
作者
Hahn, Steffen [1 ]
Hecktor, Jennifer [2 ]
Grabellus, Florian [3 ]
Hartung, Verena [4 ]
Poepper, Thorsten [4 ]
Kimmig, Rainer [2 ]
Forsting, Michael [1 ]
Antoch, Gerald [5 ]
Heusner, Till A. [5 ]
机构
[1] Univ Duisburg Essen, Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[2] Univ Duisburg Essen, Univ Hosp Essen, Dept Gynecol & Obstet, Essen, Germany
[3] Univ Duisburg Essen, Univ Hosp Essen, Inst Pathol & Neuropathol, Essen, Germany
[4] Univ Duisburg Essen, Univ Hosp Essen, Dept Nucl Med, Essen, Germany
[5] Univ Dusseldorf, Fac Med, Dept Diagnost & Intervent Radiol, D-40225 Dusseldorf, Germany
关键词
Breast cancer; axilla; lymph node metastases; PET/CT; dual-time; FDG; F-18-FDG PET/CT; FDG-PET/CT; TUMOR SIZE; TOMOGRAPHY; ARTIFACTS; QUALITY;
D O I
10.1258/ar.2012.110420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The diagnostic accuracy of FDG-PET/CT for the detection of axillary lymph node metastases in breast cancer patients acquired 60 min after FDG administration is reported to be only moderate, especially due to low sensitivity. Purpose: To test whether a delayed scan 90 min after FOG administration could enhance the diagnostic accuracy of FDG-PET/CT for the detection of axillary lymph node metastases. Material and Methods: Thirty-eight women suffering from primary breast cancer (mean age 52 years; range 25-78 years; standard deviation 14 years) underwent a pre-therapeutic dual-time-point FDG-PET/CT scan. The maximum standardized uptake value (SUVmax) of axillary lymph nodes was measured at two different time points (time point T1: 60 min after FOG injection, time point T2: 90 min after FDG injection). SUVmax of axillary lymph nodes at T1 and T2 were assessed for statistical significance using a paired Wilcoxon-Test (P < 0.05). At T1 a qualitative analysis of the FDG-PET/CT scan was performed to define physiologic and metastatic lymph nodes. At T2 an increase of the SUVmax of at least 3.75% over time was rated as indicating malignancy. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the accuracy of FDG-PET/CT for the detection of axillary lymph node metastases was calculated at time points T1 and T2. Statistically significant differences were determined using Fisher's exact test (P < 0.05). Histopathology served as the standard of reference. A compartment based analysis was done. Results: Axillary lymph nodes had a mean SUVmax of 1.6 (range 0.6-10.8; SD 1.9) at T1 and a mean SUVmax of 1.8 (range 0.5-17.9; SD 3.5) at T2. This difference was statistically significant (P = 0.047). The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases was 81%, 100%, 100%, 88%, and 92% at T1, and 88%, 50%, 56%, 85%, and 66% at T2, respectively. This difference was not statistically significant (P = 0.27). Conclusion: There is a slight increase of the FOG accumulation of axillary lymph nodes between 60 and 90 min after FDG administration. This increase did not translate into a statistical significant enhancement of the diagnostic accuracy of FDG-PET/CT for the detection of axillary lymph nodes. Especially due to false-positive results a delayed FDG-PET/CT scan 90 min after FOG administration is not able to enhance the diagnostic accuracy for the detection of lymph node metastases.
引用
收藏
页码:518 / 523
页数:6
相关论文
共 26 条
[1]  
Abner AL, 1998, CANCER-AM CANCER SOC, V83, P2502, DOI 10.1002/(SICI)1097-0142(19981215)83:12<2502::AID-CNCR14>3.0.CO
[2]  
2-I
[3]   Dual-modality PET/CT scanning with negative oral contrast agent to avoid artifacts: Introduction and evaluation [J].
Antoch, G ;
Kuehl, H ;
Kanja, J ;
Lauenstein, TC ;
Schneemann, H ;
Hauth, E ;
Jentzen, W ;
Beyer, T ;
Goehde, SC ;
Debatin, JF .
RADIOLOGY, 2004, 230 (03) :879-885
[4]   Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose:: Use and limitations [J].
Avril, N ;
Rosé, CA ;
Schelling, M ;
Dose, J ;
Kuhn, W ;
Bense, S ;
Weber, W ;
Ziegler, S ;
Graeff, H ;
Schwaiger, M .
JOURNAL OF CLINICAL ONCOLOGY, 2000, 18 (20) :3495-3502
[5]   Respiration artifacts in whole-body 18F-FDG PET/CT studies with combined PET/CT tomographs employing spiral CT technology with 1 to 16 detector rows [J].
Beyer, T ;
Rosenbaum, S ;
Veit, P ;
Stattaus, J ;
Müller, SP ;
DiFilippo, FP ;
Schöder, H ;
Mawlawi, O ;
Roberts, F ;
Bockisch, A ;
Kühl, H .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (12) :1429-1439
[6]   Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology [J].
Beyer, T ;
Antoch, G ;
Blodgett, T ;
Freudenberg, LF ;
Akhurst, T ;
Mueller, S .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) :588-596
[7]  
CARTER CL, 1989, CANCER-AM CANCER SOC, V63, P181, DOI 10.1002/1097-0142(19890101)63:1<181::AID-CNCR2820630129>3.0.CO
[8]  
2-H
[9]   The value of dual-time-point 18F-FDG PET/CT for identifying axillary lymph node metastasis in breast cancer patients [J].
Choi, W. H. ;
Yoo, I. R. ;
O, J. H. ;
Kim, S. H. ;
Chung, S. K. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1003) :593-599
[10]   Frequency and predictors of axillary lymph node metastases in invasive breast cancer [J].
Chua, B ;
Ung, O ;
Taylor, R ;
Boyages, J .
ANZ JOURNAL OF SURGERY, 2001, 71 (12) :723-728