Micromorphometrical analyses of five different ultrasonic osteotomy devices at the rabbit skull

被引:34
作者
Hollstein, Stephan [1 ]
Hoffmann, Eike [1 ]
Vogel, Juergen [2 ]
Heyroth, Frank [3 ]
Prochnow, Nora [4 ]
Maurer, Peter [1 ]
机构
[1] Klinikum Bremerhaven Reinkenheide gGmbH, Dept Oral & Maxillofacial Surg, D-27574 Bremerhaven, Germany
[2] Univ Halle Wittenberg, Inst Pharm, Halle, Germany
[3] Univ Halle Wittenberg, Ctr Mat Sci, Halle, Germany
[4] Ruhr Univ Bochum, Dept Neuroanat & Mol Brain Res, Bochum, Germany
关键词
confocal laser scanning microscopy; environmental scanning electron microscopy; piezosurgery; ultrasonic osteotomy; SCANNING-ELECTRON-MICROSCOPY; SURGERY; PIEZOSURGERY;
D O I
10.1111/j.1600-0501.2011.02185.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The recently introduced ultrasonic osteotome procedure is an alternative to conventional methods of osteotomy. The aim of the present study was to establish the differences between five recently introduced ultrasonic osteotomes and to perform micromorphological and quantitative roughness analyses of osteotomized bone surfaces. Materials and methods: Fresh, standard-sized bony samples were taken from a rabbit skull using the following ultrasonic osteotomes: the Piezosurgery (R) 3 with insert tip OT7, Piezosurgery (R) Medical with insert tip MT1-10, Piezon Master Surgery (R) with insert tip SL1, VarioSurg (R) with inert tip SG1, and Piezotome 2 with insert tip BS1 II. The required duration of time for each osteotomy was recorded. The prepared surfaces were examined via light microscopy, environmental surface electron microscopy (ESEM), and confocal laser scanning microscopy (CLSM). Results: All of the investigated piezoelectric osteotomes preserved the anatomical structure of bone. The mean roughness values of the osteotomized bone edge obtained using the investigated piezoelectric osteotomes were as follows: 2.47 mu m (Piezosurgery (R) 3), 9.79 mu m (Piezosurgery (R) Medical), 4.66 mu m (Piezon Master Surgery (R)), 6.38 mu m (VarioSurg (R)), and 6.06 mu m (Piezotome 2). Significantly higher roughness values were observed when using the Piezosurgery (R) Medical in comparison with those achieved by the Piezosurgery (R) 3 (P<0.0001) and Piezon Master Surgery (R) (P=0.002). Different osteotomy durations were achieved using the different piezoelectric osteotomes: 144 s (Piezosurgery (R) 3), 126 s (Piezosurgery (R) Medical), 142 s (Piezon Master Surgery (R)), 149 s (VarioSurg (R)), and 137 s (Piezotome 2). Conclusions: In the present study, micromorphological differences following the use of various ultrasonic devices were clearly identified. According to this study, it can be concluded that the power and the composition of the teeth of the insert tip might impact procedure duration and cutting qualities.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 18 条
[1]  
Al-Nawas B, 2001, SCANNING, V23, P227, DOI 10.1002/sca.4950230401
[2]   Impaired fracture healing in the absence of TNF-α signaling:: The role of TNF-α in endochondral cartilage resorption [J].
Gerstenfeld, LC ;
Cho, TJ ;
Kon, T ;
Aizawa, T ;
Tsay, A ;
Fitch, J ;
Barnes, GL ;
Graves, DT ;
Einhorn, TA .
JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 (09) :1584-1592
[3]   Confocal laser scanning microscopy (CLSM) for validation of non-destructive histotomography of healthy bone tissue [Konfokale Laser-Scanning Mikroskopie (CLSM) Validierung der zerstörungsfreien Histotomographie gesunden Knochengewebes.] [J].
Grötz K.A. ;
Piepkorn B. ;
Bittinger F. ;
Reichert T.E. ;
Duschner H. ;
de Aguiar E.G. ;
Kann P. ;
Wagner W. .
Mund-, Kiefer- und Gesichtschirurgie, 1998, 2 (3) :141-145
[4]   HEALING OF SURGICAL DEFECTS IN ALVEOLAR BONE PRODUCED WITH ULTRASONIC INSTRUMENTATION, CHISEL, AND ROTARY BUR [J].
HORTON, JE ;
TARPLEY, TM ;
WOOD, LD .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1975, 39 (04) :536-546
[5]   Ultrasonic scaler tip performance under various load conditions [J].
Lea, SC ;
Landini, G ;
Walmsley, AD .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2003, 30 (10) :876-881
[6]   Applications of environmental scanning electron microscopy (ESEM) in biomaterials field [J].
Manero, JM ;
Gil, FJ ;
Padrós, E ;
Planell, JA .
MICROSCOPY RESEARCH AND TECHNIQUE, 2003, 61 (05) :469-480
[7]   Micromorphometrical analysis of conventional osteotomy techniques and ultrasonic osteotomy at the rabbit skull [J].
Maurer, Peter ;
Kriwalsky, Marcus S. ;
Veras, Rafael Block ;
Vogel, Juergen ;
Syrowatka, Frank ;
Heiss, Christian .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) :570-575
[8]   The cutting-edge technique for safe osteotomies in craniofacial surgery: The piezosurgery bone scalpel [J].
Nordera, Paolo ;
di Spilimbergo, Stefano Spanio ;
Stenico, Alessandro ;
Fornezza, Umberto ;
Volpin, Lorenzo ;
Padula, Ernesto .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 120 (07) :1989-1995
[9]   Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: A pilot study in minipigs [J].
Preti, Giulio ;
Martinasso, Germana ;
Peirone, Bruno ;
Navone, Roberto ;
Manzella, Carlo ;
Muzio, Giuliana ;
Russo, Crescenzo ;
Canuto, Rosa A. ;
Schierano, Gianmario .
JOURNAL OF PERIODONTOLOGY, 2007, 78 (04) :716-722
[10]   Microarray analysis of gene expression during the inflammation and endochondral bone formation stages of rat femur fracture repair [J].
Rundle, CH ;
Wang, HL ;
Yu, HR ;
Chadwick, RB ;
Davis, EI ;
Wergedal, JE ;
Lau, KHW ;
Mohan, S ;
Ryaby, JT ;
Baylink, DJ .
BONE, 2006, 38 (04) :521-529