Micromorphometrical analyses of five different ultrasonic osteotomy devices at the rabbit skull

被引:33
|
作者
Hollstein, Stephan [1 ]
Hoffmann, Eike [1 ]
Vogel, Juergen [2 ]
Heyroth, Frank [3 ]
Prochnow, Nora [4 ]
Maurer, Peter [1 ]
机构
[1] Klinikum Bremerhaven Reinkenheide gGmbH, Dept Oral & Maxillofacial Surg, D-27574 Bremerhaven, Germany
[2] Univ Halle Wittenberg, Inst Pharm, Halle, Germany
[3] Univ Halle Wittenberg, Ctr Mat Sci, Halle, Germany
[4] Ruhr Univ Bochum, Dept Neuroanat & Mol Brain Res, Bochum, Germany
关键词
confocal laser scanning microscopy; environmental scanning electron microscopy; piezosurgery; ultrasonic osteotomy; SCANNING-ELECTRON-MICROSCOPY; SURGERY; PIEZOSURGERY;
D O I
10.1111/j.1600-0501.2011.02185.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The recently introduced ultrasonic osteotome procedure is an alternative to conventional methods of osteotomy. The aim of the present study was to establish the differences between five recently introduced ultrasonic osteotomes and to perform micromorphological and quantitative roughness analyses of osteotomized bone surfaces. Materials and methods: Fresh, standard-sized bony samples were taken from a rabbit skull using the following ultrasonic osteotomes: the Piezosurgery (R) 3 with insert tip OT7, Piezosurgery (R) Medical with insert tip MT1-10, Piezon Master Surgery (R) with insert tip SL1, VarioSurg (R) with inert tip SG1, and Piezotome 2 with insert tip BS1 II. The required duration of time for each osteotomy was recorded. The prepared surfaces were examined via light microscopy, environmental surface electron microscopy (ESEM), and confocal laser scanning microscopy (CLSM). Results: All of the investigated piezoelectric osteotomes preserved the anatomical structure of bone. The mean roughness values of the osteotomized bone edge obtained using the investigated piezoelectric osteotomes were as follows: 2.47 mu m (Piezosurgery (R) 3), 9.79 mu m (Piezosurgery (R) Medical), 4.66 mu m (Piezon Master Surgery (R)), 6.38 mu m (VarioSurg (R)), and 6.06 mu m (Piezotome 2). Significantly higher roughness values were observed when using the Piezosurgery (R) Medical in comparison with those achieved by the Piezosurgery (R) 3 (P<0.0001) and Piezon Master Surgery (R) (P=0.002). Different osteotomy durations were achieved using the different piezoelectric osteotomes: 144 s (Piezosurgery (R) 3), 126 s (Piezosurgery (R) Medical), 142 s (Piezon Master Surgery (R)), 149 s (VarioSurg (R)), and 137 s (Piezotome 2). Conclusions: In the present study, micromorphological differences following the use of various ultrasonic devices were clearly identified. According to this study, it can be concluded that the power and the composition of the teeth of the insert tip might impact procedure duration and cutting qualities.
引用
收藏
页码:713 / 718
页数:6
相关论文
共 50 条
  • [1] Micromorphometrical analysis of conventional osteotomy techniques and ultrasonic osteotomy at the rabbit skull
    Maurer, Peter
    Kriwalsky, Marcus S.
    Veras, Rafael Block
    Vogel, Juergen
    Syrowatka, Frank
    Heiss, Christian
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) : 570 - 575
  • [2] ULTRASONIC DEVICES FOR CONTINUOUS INVESTIGATIONS OF NONELECTRIC PROCESSES IN THE HUMAN SKULL
    SIMONOV, LG
    ALEKBEROV, MI
    KOSMICHESKAYA BIOLOGIYA I AVIAKOSMICHESKAYA MEDITSINA, 1989, 23 (04): : 86 - 88
  • [4] Analyses of Colour Appearances on Different Display Devices
    Javorsek, Dejana
    Mocnik, Janja
    Staresinic, Marica
    TEKSTILEC, 2015, 58 (02) : 100 - 107
  • [5] A comparison of five different analyses in the interpretation of five borehole temperature data sets
    Beck, A. E.
    Shen, P. Y.
    Beltrami, H.
    Mareschal, J. -C.
    Safanda, J.
    Sebagenzi, M. N.
    Vasseur, G.
    Wang, K.
    PALAEOGEOGRAPHY PALAEOCLIMATOLOGY PALAEOECOLOGY, 1992, 98 (2-4) : 101 - 112
  • [6] Heat production during different ultrasonic and conventional osteotomy preparations for dental implants
    Rashad, Ashkan
    Kaiser, Anja
    Prochnow, Nora
    Schmitz, Inge
    Hoffmann, Eike
    Maurer, Peter
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (12) : 1361 - 1365
  • [7] Structural and ultrastructural analyses of bone regeneration in rabbit cranial osteotomy: Piezosurgery versus traditional osteotomes
    Anesi, Alexandre
    Ferretti, Marzia
    Cavani, Francesco
    Salvatori, Roberta
    Bianchi, Michele
    Russo, Alessandro
    Chiarini, Luigi
    Palumbo, Carla
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (01) : 107 - 118
  • [8] The isolated rabbit heart: Comparison between five different modifications
    Schmitz-Spanke, S
    Seyfried, E
    Schwanke, U
    Korbmacher, B
    Sunderdiek, U
    Winter, J
    Pomblum, SG
    Pomblum, V
    Gams, E
    Schipke, JD
    HERZ, 2002, 27 (08) : 803 - 813
  • [9] Response Analyses of Micro-Ultrasonic Sensor Devices for Underwater Robotic Applications
    Mohamad Faizal Abd. Rahman
    Mohd Ikhwan Hadi Yaacob
    Mohd Rizal Arshad
    Asrulnizam Abd. Manaf
    International Journal of Social Robotics, 2012, 4 : 49 - 57
  • [10] COMPARISON OF OSTEOTOMY HEALING UNDER EXTERNAL FIXATION DEVICES WITH DIFFERENT STIFFNESS CHARACTERISTICS
    WU, JJ
    SHYR, HS
    CHAO, EYS
    KELLY, PJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08): : 1258 - 1264