Manipulation of separation selectivity of inorganic anions in electrostatic ion chromatography by the use of mixed cationic-zwitterionic micelles as the column coating solution

被引:13
|
作者
Hu, W [1 ]
Haddad, PR
Cook, H
Yamamoto, H
Hasebe, K
Tanaka, K
Fritz, JS
机构
[1] Hokkaido Univ, Grad Sch Sci, Div Chem, Sapporo, Hokkaido 0600810, Japan
[2] Univ Tasmania, Sch Chem, Hobart, Tas 7001, Australia
[3] Hokkaido Univ, Grad Sch Environm Earth Sci, Div Sci Mat, Sapporo, Hokkaido 0600810, Japan
[4] Natl Ind Res Inst Nagoya, Nagoya, Aichi 4628510, Japan
[5] Iowa State Univ, Ames Lab, USDOE, Ames, IA USA
[6] Iowa State Univ, Dept Chem, Ames, IA USA
关键词
micelles; electrostatic ion chromatography; ion chromatography; stationary phases; LC; selectivity; coated columns; inorganic anions;
D O I
10.1016/S0021-9673(01)00534-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes an electrostatic ion chromatographic system in which the separation selectivity for inorganic anions, especially for sulfate and phosphate, could be manipulated by altering the molar ratio of the zwitterionic and cationic surfactants in the column coating solution used to prepare the stationary phase. The zwitterionic surfactant used for this study was 3-(N,N-dimethyltetradecylammonio)propane (Zwittergent-3-14) and the cationic surfactant was tetradecyl-trimethylammonium (TTA). Using a reversed-phase C-18 column (250 x 4.6 mm I.D.) coated with 10/10 (mM/mM) of TTA/Zwittergent-3-14 mixed micelles as the stationary phase and either NaHCO3 or Na2CO3 aqueous solution as the eluent, together with suppressed conductivity detection, baseline separation of seven model inorganic anions was obtained. The elution order for those anions was found to be F-< HPO42- < Cl- < SO42- < NO2- < Br- < NO3-. Under the same conditions but using 1/10 (mM/mM) of TTA/Zwittergent-3-14 mixed micelles as the column coating solution, the elution order for these model ions was F- < HPO42- < SO42- < Cl- < NO2- < Br- < NO3-. The early elution of phosphate and sulfate is a unique attribute of this system. Detection limits for F-, HPO42-, Cl-, SO42-, NO2-, Br- and NO3- (S/N=3, sample injection volume 100 mul) were 0.11, 0.12, 0.12, 0.18, 0.49, 0.49, 0.52 muM, respectively. (C) 2001 Elsevier Science B;V. All rights reserved.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 19 条
  • [11] Analysis of inorganic anions in drainage water and soil solution by single-column ion chromatography
    Fernández-Boy, ME
    Cabrera, F
    Moreno, F
    JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) : 285 - 290
  • [12] Determination of inorganic anions by electrostatic ion chromatography with a cation exchange column as a pre-column for conversion of the cations into a common species
    Hasebe, K
    Sakuraba, T
    Hu, WZ
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (04) : 561 - 569
  • [13] NEW APPROACH TO THE SIMULTANEOUS SEPARATION OF INORGANIC CATIONS AND ANIONS BY ION CHROMATOGRAPHY BASED ON ION-EXCHANGE AND ELECTROSTATIC INTERACTIONS
    HU, WZ
    MIYAZAKI, A
    HARAGUCHI, H
    ANALYTICAL SCIENCES, 1995, 11 (06) : 999 - 1000
  • [14] Electrostatic Ion Chromatography of Common Anions and Cations with a Zwitterionic Surfactant-Modified Silica-C18 Column Using Water Eluent
    Masuda, Wakako
    Kozaki, Daisuke
    Nakatani, Nobutake
    Goto, Ryozo
    Mori, Masanobu
    Fugetsu, Bunshi
    Tanaka, Kazuhiko
    BUNSEKI KAGAKU, 2009, 58 (04) : 311 - 315
  • [15] Simultaneous Analysis of Inorganic Monovalent Anions/Cations Using Mixed-Bed Single-Column Ion Chromatography
    Artaches A. Kazarian
    Brett Paull
    Pavel N. Nesterenko
    Phimpha Soisungnoen
    Rodjana Burakham
    Supalax Srijaranai
    Chromatographia, 2015, 78 : 179 - 187
  • [16] Simultaneous Analysis of Inorganic Monovalent Anions/Cations Using Mixed-Bed Single-Column Ion Chromatography
    Kazarian, Artaches A.
    Paull, Brett
    Nesterenko, Pavel N.
    Soisungnoen, Phimpha
    Burakham, Rodjana
    Srijaranai, Supalax
    CHROMATOGRAPHIA, 2015, 78 (3-4) : 179 - 187
  • [17] Separation of inorganic anions by capillary ion chromatography with UV detection using poly(vinylimidazole-co-ethylene dimethacrylate) monolithic column
    Lin, Shu-Ling
    Fuh, Ming-Ren
    TALANTA, 2019, 194 : 73 - 78
  • [18] DETERMINATION OF INORGANIC ANIONS BY PHOTOMETRIC ION CHROMATOGRAPHY - USE OF A POPULAR ION-EXCHANGE COLUMN AND A CONVENTIONAL HIGH-PERFORMANCE LIQUID CHROMATOGRAPH
    HAYAKAWA, K
    HIRAKI, H
    MIYAZAKI, M
    BUNSEKI KAGAKU, 1985, 34 (07) : T71 - T76
  • [19] USE OF COMPLEXING AGENTS IN ION EXCHANGE CHROMATOGRAPHY .2. SEPARATION OF COBALT(II) AND NICKEL(II) IONS ON CATION EXCHANGE COLUMN USING AMMONIACAL AMMONIUM ACETATE SOLUTION AS ELUENT
    INCZEDY, J
    KLATSMAY.P
    ERDEY, L
    ACTA CHIMICA ACADEMIAE SCIENTARIUM HUNGARICAE, 1969, 62 (01): : 1 - &