Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling

被引:5
|
作者
Wan, Lidi [1 ,2 ]
Ma, Yajun [2 ]
Yang, Jiawei [1 ]
Jerban, Saeed [2 ]
Searleman, Adam C. [2 ]
Carl, Michael [3 ]
Le, Nicole [4 ]
Chang, Eric Y. [2 ,4 ]
Tang, Guangyu [1 ]
Du, Jiang [2 ]
机构
[1] Tongji Univ, Dept Radiol, Peoples Hosp 10, Shanghai 200072, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[3] GE Healthcare, San Diego, CA USA
[4] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
knee joint; major tissues; quantitative; Sampling Window; UTE imaging; CARTILAGE; RELAXATION; SEQUENCE; OSTEOARTHRITIS; ASSOCIATION; TENDONS; WATER; MRI; T-1; T2;
D O I
10.1002/nbm.4376
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T-2*, T-1, adiabatic T-1 rho, magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations. Errors in UTE MRI biomarkers as a function of sampling time were evaluated using a nonstretched spiral trajectory as a reference standard. No significant differences were observed by increasing the spiral sampling window from 1116 to 2232 mu s in the calculated T-2*, T-1, adiabatic T-1 rho, MTR and MMF, as allP-values were over .05 as assessed by ANOVA with two-sided Dunnett's test. Although extending the sampling window results in signal loss for short T(2)components, there was limited effect on the calculated quantitative biomarkers, with error percentages typically smaller than 5% in all the evaluated tissues. The total scan time can be reduced by up to 54% with quantification errors of less than 5% in any evaluated major tissue in the knee joint, suggesting that 3D UTE Cones MRI techniques can be greatly accelerated by using a longer spiral sampling window without causing additional quantitative bias.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Denoising of volumetric magnetic resonance imaging using multichannel three-dimensional convolutional neural network with applications on fast spin echo acquisitions
    Zhao, Shutian
    Xiao, Fan
    Griffith, James F.
    Li, Ruokun
    Chen, Weitian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09) : 6517 - 6530
  • [42] Osteochondral Lesions of the Talus Comparison of Three-Dimensional Fat-Suppressed Fast Spoiled Gradient-Echo Magnetic Resonance Imaging and Conventional Magnetic Resonance Imaging
    Hao, Da-Peng
    Zhang, Jian-Zhong
    Wang, Zhen-Chang
    Xu, Wen-Jian
    Liu, Ji-Hua
    Yang, Ben-Tao
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2010, 100 (03) : 189 - 194
  • [43] Microanatomy of the cerebellopontine angle and internal auditory canal: Study with new magnetic resonance imaging technique using three-dimensional fast spin echo
    Mitsuoka, H
    Arai, H
    Tsunoda, A
    Okuda, O
    Sato, K
    Makita, J
    NEUROSURGERY, 1999, 44 (03) : 561 - 566
  • [44] Three-dimensional reconstruction of subject-specific knee joint using computed tomography and magnetic resonance imaging image data fusions
    Dong, Yuefu
    Mou, Zhifang
    Huang, Zhenyu
    Hu, Guanghong
    Dong, Yinghai
    Xu, Qingrong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (10) : 1083 - 1093
  • [45] Accelerated Stack-of-Spirals Free-Breathing Three-Dimensional Ultrashort Echo Time Lung Magnetic Resonance Imaging: A Feasibility Study in Patients With Breast Cancer
    Cha, Min Jae
    Ahn, Hye Shin
    Choi, Hyewon
    Park, Hyun Jeong
    Benkert, Thomas
    Pfeuffer, Josef
    Paek, Mun Young
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [46] Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: establishment of flip angles for evaluation of cartilage at 1.5 T and 3.0 T
    Moriya, Susumu
    Miki, Yukio
    Matsuno, Yukako
    Okada, Masayo
    ACTA RADIOLOGICA, 2012, 53 (07) : 790 - 794
  • [47] Automated three-dimensional major white matter bundle segmentation using diffusion magnetic resonance imaging
    Andica, Christina
    Kamagata, Koji
    Aoki, Shigeki
    ANATOMICAL SCIENCE INTERNATIONAL, 2023, 98 (03) : 318 - 336
  • [48] Achilles tendon and enthesis assessment using ultrashort echo time magnetic resonance imaging (UTE-MRI) T1 and magnetization transfer (MT) modeling in psoriatic arthritis
    Moazamian, Dina
    Athertya, Jiyo S.
    Dwek, Sophia
    Lombardi, Alecio F.
    Mohammadi, Hamidreza Shaterian
    Sedaghat, Sam
    Jang, Hyungseok
    Ma, Yajun
    Chung, Christine B.
    Du, Jiang
    Jerban, Saeed
    Chang, Eric Y.
    NMR IN BIOMEDICINE, 2024, 37 (01)
  • [49] Evaluation of the menisci of the knee joint using three-dimensional isotropic resolution fast spin-echo imaging: diagnostic performance in 250 patients with surgical correlation
    Kijowski, Richard
    Davis, Kirkland W.
    Blankenbaker, Donna G.
    Woods, Michael A.
    Del Rio, Alejandro Munoz
    De Smet, Arthur A.
    SKELETAL RADIOLOGY, 2012, 41 (02) : 169 - 178
  • [50] Validity of gradient-echo three-dimensional delayed gadolinium-enhanced magnetic resonance imaging of hip joint cartilage: A histologically controlled study
    Zilkens, Christoph
    Miese, Falk
    Herten, Monika
    Kurzidem, Sabine
    Jaeger, Marcus
    Koenig, Dietmar
    Antoch, Gerald
    Krauspe, Ruediger
    Bittersohl, Bernd
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : E81 - E86