Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling

被引:5
|
作者
Wan, Lidi [1 ,2 ]
Ma, Yajun [2 ]
Yang, Jiawei [1 ]
Jerban, Saeed [2 ]
Searleman, Adam C. [2 ]
Carl, Michael [3 ]
Le, Nicole [4 ]
Chang, Eric Y. [2 ,4 ]
Tang, Guangyu [1 ]
Du, Jiang [2 ]
机构
[1] Tongji Univ, Dept Radiol, Peoples Hosp 10, Shanghai 200072, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
[3] GE Healthcare, San Diego, CA USA
[4] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
knee joint; major tissues; quantitative; Sampling Window; UTE imaging; CARTILAGE; RELAXATION; SEQUENCE; OSTEOARTHRITIS; ASSOCIATION; TENDONS; WATER; MRI; T-1; T2;
D O I
10.1002/nbm.4376
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study is to investigate the effect of extending the spiral sampling window on quantitative 3D ultrashort echo time (UTE) Cones imaging of major knee joint tissues including articular cartilage, menisci, tendons and ligaments at 3 T. Nine cadaveric human whole knee specimens were imaged on a 3 T clinical MRI scanner. A series of quantitative 3D UTE Cones imaging biomarkers including T-2*, T-1, adiabatic T-1 rho, magnetization transfer ratio (MTR) and macromolecular fraction (MMF) were estimated using spiral sampling trajectories with various durations. Errors in UTE MRI biomarkers as a function of sampling time were evaluated using a nonstretched spiral trajectory as a reference standard. No significant differences were observed by increasing the spiral sampling window from 1116 to 2232 mu s in the calculated T-2*, T-1, adiabatic T-1 rho, MTR and MMF, as allP-values were over .05 as assessed by ANOVA with two-sided Dunnett's test. Although extending the sampling window results in signal loss for short T(2)components, there was limited effect on the calculated quantitative biomarkers, with error percentages typically smaller than 5% in all the evaluated tissues. The total scan time can be reduced by up to 54% with quantification errors of less than 5% in any evaluated major tissue in the knee joint, suggesting that 3D UTE Cones MRI techniques can be greatly accelerated by using a longer spiral sampling window without causing additional quantitative bias.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantitative three-dimensional ultrashort echo time cones imaging of the knee joint with motion correction
    Wu, Mei
    Zhao, Wei
    Wan, Lidi
    Kakos, Lena
    Li, Liang
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2020, 33 (01)
  • [2] Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging
    Namiranian, Behnam
    Jerban, Saeed
    Ma, Yajun
    Dorthe, Erik W.
    Masoud-Afsahi, Amir
    Wong, Jonathan
    Wei, Zhao
    Chen, Yanjun
    D'Lima, Darryl
    Chang, Eric Y.
    Du, Jiang
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [3] Fast quantitative 3D ultrashort echo time MRI of cortical bone using extended cones sampling
    Wan, Lidi
    Zhao, Wei
    Ma, Yajun
    Jerban, Saeed
    Searleman, Adam C.
    Carl, Michael
    Chang, Eric Y.
    Tang, Guangyu
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 225 - 236
  • [4] Three-dimensional ultrashort echo time cones (3D UTE-Cones) magnetic resonance imaging of entheses and tendons
    Chen, Bimin
    Zhao, Yinghua
    Cheng, Xin
    Ma, Yajun
    Chang, Eric Y.
    Kavanaugh, Arthur
    Liu, Sirun
    Du, Jiang
    MAGNETIC RESONANCE IMAGING, 2018, 49 : 4 - 9
  • [5] Three-dimensional ultrashort echo time cones T1ρ (3D UTE-cones-T1ρ) imaging
    Ma, Ya-Jun
    Carl, Michael
    Shao, Hongda
    Tadros, Anthony S.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2017, 30 (06)
  • [6] Magnetic resonance imaging (MRI) of articular cartilage of the knee using ultrashort echo time (uTE) sequences with spiral acquisition
    Goto, Hajimu
    Fujii, Masahiko
    Iwama, Yuki
    Aoyama, Nobukazu
    Ohno, Yoshiharu
    Sugimura, Kazuro
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (03) : 318 - 323
  • [7] Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of Bone: An Update
    Ma, Ya-Jun
    Jerban, Saeed
    Jang, Hyungseok
    Chang, Douglas
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [8] Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging
    Ren, Cui
    Zhu, Qiao
    Li, Qing
    Sommer, Stefan
    Zhang, Xianchang
    Yuan, Huishu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4141 - 4154
  • [9] Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients
    Zeimpekis, Konstantinos G.
    Geiger, Julia
    Wiesinger, Florian
    Delso, Gaspar
    Kellenberger, Christian J.
    PEDIATRIC RADIOLOGY, 2021, 51 (01) : 57 - 65
  • [10] Deep Convolutional Neural Network for Dedicated Regions-of-Interest Based Multi-Parameter Quantitative Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Knee Joint
    Lu, Xing
    Ma, Yajun
    Chang, Eric Y.
    Athertya, Jiyo
    Jang, Hyungseok
    Jerban, Saeed
    Covey, Dana C.
    Bukata, Susan
    Chung, Christine B.
    Du, Jiang
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (05): : 2126 - 2134