An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments

被引:57
作者
Peters, O. A. [1 ]
Gluskin, A. K. [1 ,2 ]
Weiss, R. A. [1 ,3 ]
Han, J. T. [1 ,4 ]
机构
[1] Univ Pacific, Dept Endodont, Arthur A Dugoni Sch Dent, San Francisco, CA 94941 USA
[2] Univ Pacific, Dept Biol Sci, Stockton, CA 95211 USA
[3] Univ Michigan, Coll Literature Sci & Arts, Ann Arbor, MI 48109 USA
[4] Univ Calif Berkeley, Berkeley, CA 94720 USA
关键词
fatigue; force; Hyflex; torque; METALLURGICAL CHARACTERIZATION; BENDING PROPERTIES; PHASE-TRANSFORMATION; SHAPE-MEMORY; CLINICAL-USE; FATIGUE; WIRE; TORQUE; SAFETY; FORCE;
D O I
10.1111/j.1365-2591.2012.02067.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Peters OA, Gluskin AK, Weiss RA, Han JT. An in vitro assessment of the physical properties of novel Hyflex nickeltitanium rotary instruments. International Endodontic Journal,similar to 45, 1027-1034, 2012. Abstract Aim To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickeltitanium alloy. Methodology The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90 degrees, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis. Results Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle. Conclusions Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions.
引用
收藏
页码:1027 / 1034
页数:8
相关论文
共 29 条
[21]   Current challenges and concepts in the preparation of root canal systems: A review [J].
Peters, OA .
JOURNAL OF ENDODONTICS, 2004, 30 (08) :559-567
[22]   Analysis of torque and force with differently tapered rotary endodontic instruments in vitro [J].
Schrader, C ;
Peters, OA .
JOURNAL OF ENDODONTICS, 2005, 31 (02) :120-123
[23]   Effect of Environment on Fatigue Failure of Controlled Memory Wire Nickel-Titanium Rotary Instruments [J].
Shen, Ya ;
Qian, Wei ;
Abtin, Houman ;
Gao, Yuan ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2012, 38 (03) :376-380
[24]   Metallurgical Characterization of Controlled Memory Wire Nickel-Titanium Rotary Instruments [J].
Shen, Ya ;
Zhou, Hui-min ;
Zheng, Yu-feng ;
Campbell, Les ;
Peng, Bin ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2011, 37 (11) :1566-1571
[25]   Fatigue Testing of Controlled Memory Wire Nickel-Titanium Rotary Instruments [J].
Shen, Ya ;
Qian, Wei ;
Abtin, Houman ;
Gao, Yuan ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2011, 37 (07) :997-1001
[26]   Bending Properties of a New Nickel-Titanium Alloy with a Lower Percent by Weight of Nickel [J].
Testarelli, Luca ;
Plotino, Gianluca ;
Al-Sudani, Dina ;
Vincenzi, Valentina ;
Giansiracusa, Alessio ;
Grande, Nicola M. ;
Gambarini, Gianluca .
JOURNAL OF ENDODONTICS, 2011, 37 (09) :1293-1295
[27]   An overview of nickel-titanium alloys used in dentistry [J].
Thompson, SA .
INTERNATIONAL ENDODONTIC JOURNAL, 2000, 33 (04) :297-310
[28]   Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments [J].
Ullmann, CJ ;
Peters, OA .
JOURNAL OF ENDODONTICS, 2005, 31 (03) :183-186
[29]   A metallurgical characterization of ten endodontic Ni-Ti instruments: assessing the clinical relevance of shape memory and superelastic properties of Ni-Ti endodontic instruments [J].
Zinelis, S. ;
Eliades, T. ;
Eliades, G. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (02) :125-134