An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments

被引:57
作者
Peters, O. A. [1 ]
Gluskin, A. K. [1 ,2 ]
Weiss, R. A. [1 ,3 ]
Han, J. T. [1 ,4 ]
机构
[1] Univ Pacific, Dept Endodont, Arthur A Dugoni Sch Dent, San Francisco, CA 94941 USA
[2] Univ Pacific, Dept Biol Sci, Stockton, CA 95211 USA
[3] Univ Michigan, Coll Literature Sci & Arts, Ann Arbor, MI 48109 USA
[4] Univ Calif Berkeley, Berkeley, CA 94720 USA
关键词
fatigue; force; Hyflex; torque; METALLURGICAL CHARACTERIZATION; BENDING PROPERTIES; PHASE-TRANSFORMATION; SHAPE-MEMORY; CLINICAL-USE; FATIGUE; WIRE; TORQUE; SAFETY; FORCE;
D O I
10.1111/j.1365-2591.2012.02067.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Peters OA, Gluskin AK, Weiss RA, Han JT. An in vitro assessment of the physical properties of novel Hyflex nickeltitanium rotary instruments. International Endodontic Journal,similar to 45, 1027-1034, 2012. Abstract Aim To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickeltitanium alloy. Methodology The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90 degrees, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis. Results Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle. Conclusions Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions.
引用
收藏
页码:1027 / 1034
页数:8
相关论文
共 29 条
[1]   Metallurgical Characterization of a New Nickel-Titanium Wire for Rotary Endodontic Instruments [J].
Alapati, Satish B. ;
Brantley, William A. ;
Iijima, Masahiro ;
Clark, William A. T. ;
Kovarik, Libor ;
Buie, Caesar ;
Liu, Jie ;
Ben Johnson, William .
JOURNAL OF ENDODONTICS, 2009, 35 (11) :1589-1593
[2]   Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals [J].
Bahia, MGA ;
Buono, VTL .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (02) :249-255
[3]   Torsional Profiles of New and Used Revo-S Rotary Instruments: An In Vitro Study [J].
Basrani, Bettina ;
Roth, Karina ;
Sas, Geoffrey ;
Kishen, Anil ;
Peters, Ove A. .
JOURNAL OF ENDODONTICS, 2011, 37 (07) :989-992
[4]   Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: Value of the safety quotient [J].
Blum, JY ;
Machtou, P ;
Ruddle, C ;
Micallef, JP .
JOURNAL OF ENDODONTICS, 2003, 29 (09) :567-575
[5]   Defects in ProTaper S1 instruments after clinical use: fractographic examination [J].
Cheung, GSP ;
Peng, B ;
Bian, Z ;
Shen, Y ;
Darvell, BW .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (11) :802-809
[6]  
ColteneEndo, 2012, HYFLEXCM BROCH
[7]  
ColteneEndo, 2012, FIL SEQ STEP STEP CA
[8]  
ColteneEndo, 2012, CROWN DOWN TECHN STE
[9]   Some unsolved aspects of Nitinol [J].
Duerig, T. W. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2006, 438 :69-74
[10]  
Duerig TW, 1996, BIO-MED MATER ENG, V6, P255