Reliable determination of contact angle from the height and volume of sessile drops

被引:10
作者
Behroozi, F. [1 ]
Behroozi, P. S. [2 ]
机构
[1] Univ Northern Iowa, Dept Phys, Cedar Falls, IA 50614 USA
[2] Univ Arizona, Dept Astron, Tucson, AZ 85721 USA
关键词
SURFACE-TENSION; SHAPE-ANALYSIS; PROFILE; SIZE; ROUGHNESS;
D O I
10.1119/1.5078512
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Contact angle is an important parameter in characterizing the wetting properties of fluids. For this reason, accurate measurement of the contact angle at liquid-solid interfaces is of great importance in industrial and scientific applications. The most common method for measuring the contact angle is to obtain it directly from the profile of a sessile drop. Though convenient, this method suffers from certain inherent drawbacks. Here, we describe an alternative method that uses the height and volume of a sessile drop as constraints to construct its profile by numerical integration of two parametric differential equations. The integration yields, self consistently, the average value of the contact angle along the entire contact line as well as the footprint radius of the drop and its crown radius of curvature. As a test case, the new method is used to obtain the contact angle of pure water on two different substrates, Teflon and Lucite. For each substrate, four drops ranging in volume from 10. to 40 mu l are used. The computed contact angles are consistent across the four different drop sizes for each substrate and are in good agreement with the literature values. (C) 2019 American Association of Physics Teachers.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 33 条
[1]  
[Anonymous], 1870, Ann. Phys. Chem., DOI DOI 10.1002/ANDP.18702150102
[2]  
[Anonymous], PROPERTIES MATTER
[3]  
[Anonymous], PHILOS MAG
[4]  
[Anonymous], 2004, Capillarity and Wetting Phenomena, DOI DOI 10.1007/978-0-387-21656-0
[5]  
[Anonymous], WETTING 101
[6]   A Robust Polynomial Fitting Approach for Contact Angle Measurements [J].
Atefi, Ehsan ;
Mann, J. Adin, Jr. ;
Tavana, Hossein .
LANGMUIR, 2013, 29 (19) :5677-5688
[7]   Determination of contact angle from the maximum height of enlarged drops on solid surfaces [J].
Behroozi, F. .
AMERICAN JOURNAL OF PHYSICS, 2012, 80 (04) :284-288
[8]   The profile of a dew drop [J].
Behroozi, F ;
Macomber, HK ;
Dostal, JA ;
Behroozi, CH ;
Lambert, BK .
AMERICAN JOURNAL OF PHYSICS, 1996, 64 (09) :1120-1125
[9]   Determination of surface tension and contact angle from the shapes of axisymmetric fluid interfaces without use of apex coordinates [J].
Cabezas, M. Guadalupe ;
Bateni, Arash ;
Montanero, Jose M. ;
Neumann, A. Wilhelm .
LANGMUIR, 2006, 22 (24) :10053-10060
[10]   ANALYTICAL SOLUTION FOR PROFILE AND VOLUME OF A SMALL DROP OR BUBBLE SYMMETRICAL ABOUT A VERTICAL AXIS [J].
CHESTERS, AK .
JOURNAL OF FLUID MECHANICS, 1977, 81 (AUG5) :609-624