Ratiometric Electrochemical Immunosensor Based on L-cysteine Grafted Ferrocene for Detection of Neuron Specific Enolase

被引:21
作者
Huang, Xinyi [1 ]
Miao, Juncong [1 ]
Fang, Jinglong [1 ]
Xu, Xiaoting [1 ]
Wei, Qin [1 ]
Cao, Wei [1 ]
机构
[1] Jinan Univ, Sch Chem & Chem Engn, Key Lab Interfacial React & Sensing Anal, Shandong Univ, Jinan 250022, Peoples R China
关键词
Ratiometric electrochemical immunosensor; NSE; DPV; Ultra sensitive; ULTRASENSITIVE DETECTION; NANOPARTICLES; IMMUNOASSAY; STRATEGY; ASSAY;
D O I
10.1016/j.talanta.2021.123075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to realize the ultra sensitive detection of Neuron specific enolase (NSE) in human serum, we chose electrochemical immunosensor as a simple analytical method. During the experiment, we found that the peak value signals of Cu-MOFs-Au and Fc-L-Cys were significantly changed at -0.20 V and 0.20 V potentials by DPV. So a ratiometric electrochemical immunosensor for quantitative analysis of NSE was prepared for Cu-MOFs-Au as the electrode sensing surface and Fc-L-Cys as the label of Ab2. The data and performances of the immunosensor were tested and analyzed by DPV. Cu-MOFs not only provide the required signal for the immunosensor, but also have a large specific surface area, which can provide more sites for the placement of Au nanoparticles. L-cysteine (L-Cys) can prevent a large amount of Fc-COOH leakage, so that Fc+ can stably provide another required signal. With the beefing up of NSE concentration, redox peak of Cu-MOFs-Au decreased and that of Fc-L-Cys raised. The ratio (Delta I=Delta ICu/Delta IFc) of two different signals was linear with the logarithm of NSE concentration in a certain value range. In brief, with the optimized experimental conditions, the immunosensor showed excellent performance in the concentration range of 1 pg/mL to 1 mu g/mL, and the detection limit was 0.011 pg/mL. Compared with other immunosensors, it showed an unexpected high sensitivity. This method also provided a new idea for the ultra sensitive quantitative detection of other biomarkers.
引用
收藏
页数:8
相关论文
共 43 条
[1]   Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode [J].
Aydin, Elif Burcu ;
Aydin, Muhammet ;
Sezginturk, Mustafa Kemal .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 306
[2]   Label-Free Electrochemical Immunosensor for Ultrasensitive Detection of Carbohydrate Antigen 125 Based on Antibody-Immobilized Biocompatible MOF-808/CNT [J].
Biswas, Sudip ;
Lan, Qingchun ;
Xie, Yao ;
Sun, Xin ;
Wang, Yang .
ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (02) :3295-3302
[3]   Ratiometric electrochemical immunoassay based on internal reference value for reproducible and sensitive detection of tumor marker [J].
Cai, Xiaohui ;
Weng, Shaohuang ;
Guo, Rubin ;
Lin, Liqing ;
Chen, Wei ;
Zheng, Zongfu ;
Huang, Zhengjun ;
Lin, Xinhua .
BIOSENSORS & BIOELECTRONICS, 2016, 81 :173-180
[4]   Ultrasensitive ratiometric electrochemical immunoassay of N-terminal pro-B-type natriuretic peptide based on three-dimensional PtCoNi hollow multi-branches/ferrocene-grafted-ionic liquid and Co-N-C nanosheets [J].
Chen, Yao ;
Wang, Xiao-Yu ;
Wang, Ai-Jun ;
Mei, Li-Ping ;
Yuan, Pei-Xin ;
Luo, Xiliang ;
Feng, Jiu-Ju .
SENSORS AND ACTUATORS B-CHEMICAL, 2021, 326 (326)
[5]   Three dimensional sea-urchin-like PdAuCu nanocrystals/ferrocene-grafted-polylysine as an efficient probe to amplify the electrochemical signals for ultrasensitive immunoassay of carcinoembryonic antigen [J].
Chen, Yao ;
Wang, Ai-Jun ;
Yuan, Pei-Xin ;
Luo, Xiliang ;
Xue, Yadong ;
Feng, Jiu-Ju .
BIOSENSORS & BIOELECTRONICS, 2019, 132 :294-301
[6]   Dual-Mode Electrochemical Assay of Prostate-Specific Antigen Based on Antifouling Peptides Functionalized with Electrochemical Probes and Internal References [J].
Ding, Caifeng ;
Wang, Xinyan ;
Luo, Xiliang .
ANALYTICAL CHEMISTRY, 2019, 91 (24) :15846-15852
[7]   Microflowers Comprised of Cu/CuxO/NC Nanosheets as Electrocatalysts and Horseradish Peroxidase Mimics [J].
Ding, Longhua ;
Yan, Fei ;
Zhang, Yuhai ;
Liu, Lei ;
Yu, Xin ;
Liu, Hong .
ACS APPLIED NANO MATERIALS, 2020, 3 (01) :617-623
[8]   Signal amplification strategy for sensitive immunoassay of prostate specific antigen (PSA) based on ferrocene incorporated polystyrene spheres [J].
Ding, Lu ;
You, Jinmao ;
Kong, Rongmei ;
Qu, Fengli .
ANALYTICA CHIMICA ACTA, 2013, 793 :19-25
[9]   Self-Assembled Monolayer Epitope Bridges for Molecular Imprinting and Cancer Biomarker Sensing [J].
Drzazgowska, Julia ;
Schmid, Bianca ;
Suessmuth, Roderich D. ;
Altintas, Zeynep .
ANALYTICAL CHEMISTRY, 2020, 92 (07) :4798-4806
[10]   Novel electrochemical dual-aptamer-based sandwich biosensor using molybdenum disulfide/carbon aerogel composites and Au nanoparticles for signal amplification [J].
Fang, Lin-Xia ;
Huang, Ke-Jing ;
Liu, Yang .
BIOSENSORS & BIOELECTRONICS, 2015, 71 :171-178