Relationship between sick building syndrome and indoor air quality among hospital staff

被引:18
作者
Arikan, Inci [1 ]
Tekin, Omer Faruk [1 ]
Erbas, Oguzhan [2 ]
机构
[1] Kutahya Hlth Sci Univ, Dept Publ Hlth, Med Fac, Kutahya, Turkey
[2] Dumlupinar Univ, Dept Mech Engn, Fac Engn Kutahya, Kutahya, Turkey
来源
MEDICINA DEL LAVORO | 2018年 / 109卷 / 06期
关键词
Sick building syndrome; hospital; indoor air quality; PERSONAL FACTORS; SYNDROME SBS; SYMPTOMS; WORK; PREVALENCE; CLASSROOMS;
D O I
10.23749/mdl.v110i6.7628
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Sick building syndrome (SBS) is defined as a condition occurring in those who live or work in a modern building and who suffer from symptoms such as headache, fatigue, lack of concentration and irritation of the skin and mucous membranes. Objectives: The aim of this study was to evaluate the relationship between personal characteristics, environmental factors and the prevalence of SBS among the secretaries working in a hospital. Method: In this cross-sectional study, questionnaires were administered to all secretaries who were working in Kutahya hospital in January and March 2018. The questionnaire used in the study included the sociodemographic characteristics of the participants and the question form "MM 040 NA Hospital" to evaluate SBS symptoms. These symptoms were the clinical symptoms reported by the secretaries as a result of exposure to factors within the hospital. Temperature, humidity, carbon dioxide concentration, light intensity and noise level were measured in the indoor environment of the hospital. Chi square test, Spearman's correlation coefficient and logistic regression models were used in the analysis of data. Results: The study was completed with 177 people, 61.6% women, and the mean age was 30.14 +/- 5.7. The prevalence of SBS was found to be 20.9%. The risk of SBS was found to be 2.9 times higher for females, 2.8 times higher for individuals who described the working environment as dusty, 2.6 times higher for subjects complaining of stuffy "bad" air, dry air and an unpleasant odour. All measurements were found to be within acceptable limits. The risk of SBS was found to be 1.2 times higher with increases in the measured noise level, and 2.1 times higher with increased carbon dioxide (CO2) concentrations. Conclusion: The factors impacting the risk of experiencing SBS were determined. Bearing these factors in mind, we think that hospital administrations should be informed about arrangements and measures that will improve the quality of the internal environment of the hospital.
引用
收藏
页码:435 / 443
页数:9
相关论文
共 30 条
[1]  
American Society of Heating Refrigerating and Air Conditioning Engineer (ASHRAE) Standard, 2013, VENT ACC IND AIR QUA, P38
[2]  
Andersson K., 1992, NATO/CCMS Pilot Study on Indoor Air Quality. Fourth Plenary Meeting. Epidemiology and Medical Management of Building-related Complaints and Illnesses. Report on a meeting held in Oslo, Norway, 19-21 August, P47
[3]  
ANDERSSON K, 1988, HLTH BUILDINGS 88, V1, P139
[4]  
[Anonymous], 1989, 621989 ASHRAE
[5]  
[Anonymous], 2013, Indoor Air Quality Handbook
[6]   Evaluating prevalence and risk factors of building-related symptoms among office workers: Seasonal characteristics of symptoms and psychosocial and physical environmental factors [J].
Azuma, Kenichi ;
Ikeda, Koichi ;
Kagi, Naoki ;
Yanagi, U. ;
Osawa, Haruki .
ENVIRONMENTAL HEALTH AND PREVENTIVE MEDICINE, 2017, 22 (01)
[7]  
Chirico F., 2017, Journal of Health and Social Sciences, V2, P31, DOI [10.19204/2017/prvl3, DOI 10.19204/2017/PRVL3]
[8]   Mucous membrane and lower respiratory building related symptoms in relation to indoor carbon dioxide concentrations in the 100-building BASE dataset [J].
Erdmann, CA ;
Apte, MG .
INDOOR AIR, 2004, 14 :127-134
[9]   Baseline prevalence of symptoms related to indoor environment [J].
Eriksson, Nils M. ;
Stenberg, Berndt G. T. .
SCANDINAVIAN JOURNAL OF PUBLIC HEALTH, 2006, 34 (04) :387-396
[10]   INVESTIGATING AN OUTBREAK OF NON-SPECIFIC BUILDING-RELATED SYMPTOMS IN WORKERS OF A GENERAL HOSPITAL [J].
Gomez-Acebo, Ines ;
Dierssen-Sotos, Trinidad ;
Perez-Belmonte, Elena ;
Llorca, Javier .
INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2013, 26 (04) :563-571