Wearable Potentiometric Sensors for Medical Applications

被引:107
作者
Cuartero, Maria [1 ]
Parrilla, Marc [1 ]
Crespo, Gaston A. [1 ]
机构
[1] KTH Royal Inst Technol, Dept Chem, Teknikringen 30, SE-10044 Stockholm, Sweden
基金
瑞典研究理事会;
关键词
potentiometry; all-solid-state; wearable sensing; sampling cell; iontophoresis; sweat analysis; clinical decision-making; cystic fibrosis; ION-SELECTIVE ELECTRODES; CYSTIC-FIBROSIS; MOUTHGUARD BIOSENSOR; SWEAT STIMULATION; CARBON NANOTUBES; CHALLENGES; PH; PHARMACEUTICALS; QUANTIFICATION; TECHNOLOGIES;
D O I
10.3390/s19020363
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Wearable potentiometric sensors have received considerable attention owing to their great potential in a wide range of physiological and clinical applications, particularly involving ion detection in sweat. Despite the significant progress in the manner that potentiometric sensors are integrated in wearable devices, in terms of materials and fabrication approaches, there is yet plenty of room for improvement in the strategy adopted for the sample collection. Essentially, this involves a fluidic sampling cell for continuous sweat analysis during sport performance or sweat accumulation via iontophoresis induction for one-spot measurements in medical settings. Even though the majority of the reported papers from the last five years describe on-body tests of wearable potentiometric sensors while the individual is practicing a physical activity, the medical utilization of these devices has been demonstrated on very few occasions and only in the context of cystic fibrosis diagnosis. In this sense, it may be important to explore the implementation of wearable potentiometric sensors into the analysis of other biofluids, such as saliva, tears and urine, as herein discussed. While the fabrication and uses of wearable potentiometric sensors vary widely, there are many common issues related to the analytical characterization of such devices that must be consciously addressed, especially in terms of sensor calibration and the validation of on-body measurements. After the assessment of key wearable potentiometric sensors reported over the last five years, with particular attention paid to those for medical applications, the present review offers tentative guidance regarding the characterization of analytical performance as well as analytical and clinical validations, thereby aiming at generating debate in the scientific community to allow for the establishment of well-conceived protocols.
引用
收藏
页数:24
相关论文
共 77 条
[1]   Novel flow-through bulk optode for spectrophotometric determination of lithium in pharmaceuticals and saliva [J].
Albero, M. I. ;
Ortuno, J. A. ;
Garcia, M. S. ;
Cuartero, M. ;
Alcaraz, M. C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01) :133-138
[2]   A wearable patch for continuous monitoring of sweat electrolytes during exertion [J].
Alizadeh, Azar ;
Burns, Andrew ;
Lenigk, Ralf ;
Gettings, Rachel ;
Ashe, Jeffrey ;
Porter, Adam ;
McCaul, Margaret ;
Barrett, Ruairi ;
Diamond, Dermot ;
White, Paddy ;
Skeath, Perry ;
Tomczak, Melanie .
LAB ON A CHIP, 2018, 18 (17) :2632-2641
[3]   The significance of sweat Cl/Na ratio in patients with borderline sweat test [J].
Augarten, A ;
Hacham, S ;
Kerem, E ;
Kerem, BS ;
Szeinberg, A ;
Laufer, J ;
Doolman, R ;
Altshuler, R ;
Blau, H ;
Bentur, L ;
Gazit, E ;
Katznelson, D ;
Yahav, Y .
PEDIATRIC PULMONOLOGY, 1995, 20 (06) :369-371
[4]   Modern Potentiometry [J].
Bakker, Eric ;
Pretsch, Ernoe .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (30) :5660-5668
[5]   Wearable Chemical Sensors: Present Challenges and Future Prospects [J].
Bandodkar, Amay J. ;
Jeerapan, Itthipon ;
Wang, Joseph .
ACS SENSORS, 2016, 1 (05) :464-482
[6]   Tattoo-Based Wearable Electrochemical Devices: A Review [J].
Bandodkar, Amay J. ;
Jia, Wenzhao ;
Wang, Joseph .
ELECTROANALYSIS, 2015, 27 (03) :562-572
[7]   Reducing the thrombogenicity of ion-selective electrode membranes through the use of a silicone-modified segmented polyurethane [J].
Berrocal, MJ ;
Badr, IHA ;
Gao, DO ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5328-5333
[8]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[9]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[10]   in vivo ischemia monitoring array for endoscopic surgery [J].
Bogachan Tahirbegi, Islam ;
Mir, Monica ;
Schostek, Sebastian ;
Schurr, Marc ;
Samitier, Josep .
BIOSENSORS & BIOELECTRONICS, 2014, 61 :124-130