Evaluation of a portable hyperspectral imager for medical imaging applications

被引:4
作者
Allen, David W. [1 ]
Litorja, Maritoni [1 ]
Brown, Steven W. [1 ]
Zong, Yuqin [1 ]
机构
[1] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
来源
NEXT-GENERATION SPECTROSCOPIC TECHNOLOGIES | 2007年 / 6765卷
关键词
hyperspectral; stray light; calibration; medical imaging;
D O I
10.1117/12.733189
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Portable hyperspectral imagers are becoming commonly available as a commercial product. A liquid crystal tunable filter based CCD imager was evaluated and characterized for spectral stray light using a tunable laser facility. The hyperspectral imager is currently being used to investigate the use of hyperspectral imaging in medical applications. This paper discusses the imager design and performance, the characterization of this system, and medical imaging as a related application. Imagers of this type may be fundamental to transferring radiometric scales using a hyperspectral image projector. The use of the hyperspectral imager for use with a hyperspectral image projector is also discussed.
引用
收藏
页数:10
相关论文
共 21 条
[1]   Calibration of inexpensive pushbroom imaging spectrometers [J].
Bowles, J ;
Kappus, M ;
Antoniades, J ;
Baumback, M ;
Czarnaski, M ;
Davis, CO ;
Grossmann, J .
METROLOGIA, 1998, 35 (04) :657-661
[2]   Hyperspectral image projector for advanced sensor characterization [J].
Brown, S. W. ;
Rice, J. P. ;
Neira, J. E. ;
Bousquet, R. ;
Johnson, B. C. .
EARTH OBSERVING SYSTEMS XI, 2006, 6296
[3]   Facility for spectral irradiance and radiance responsivity calibrations using uniform sources [J].
Brown, Steven W. ;
Eppeldauer, George P. ;
Lykke, Keith R. .
APPLIED OPTICS, 2006, 45 (32) :8218-8237
[4]   Hyperspectral imaging applied to medical diagnoses and food safety [J].
Carrasco, O ;
Gomez, R ;
Chainani, A ;
Roper, W .
GEO-SPATIAL AND TEMPORAL IMAGE AND DATA EXPLOITATION III, 2003, 5097 :215-221
[5]  
COHEN D, 1999, IEEE
[6]   Ocean PHILLS hyperspectral imager: design, characterization, and calibration [J].
Davis, CO ;
Bowles, J ;
Leathers, RA ;
Korwan, D ;
Downes, TV ;
Snyder, WA ;
Rhea, WJ ;
Chen, W ;
Fisher, J ;
Bissett, WP ;
Reisse, RA .
OPTICS EXPRESS, 2002, 10 (04) :210-221
[7]   Demonstration of a computed-tomography imaging spectrometer using a computer-generated hologram disperser [J].
Descour, MR ;
Volin, CE ;
Dereniak, EL ;
Gleeson, TM ;
Hopkins, MF ;
Wilson, DW ;
Maker, PD .
APPLIED OPTICS, 1997, 36 (16) :3694-3698
[8]   Imaging spectroscopy using tunable filters: A review [J].
Gat, N .
WAVELET APPLICATIONS VII, 2000, 4056 :50-64
[9]   IMAGING SPECTROMETRY FOR EARTH REMOTE-SENSING [J].
GOETZ, AFH ;
VANE, G ;
SOLOMON, JE ;
ROCK, BN .
SCIENCE, 1985, 228 (4704) :1147-1153
[10]   Imaging spectroscopy and the Airborne Visible Infrared Imaging Spectrometer (AVIRIS) [J].
Green, RO ;
Eastwood, ML ;
Sarture, CM ;
Chrien, TG ;
Aronsson, M ;
Chippendale, BJ ;
Faust, JA ;
Pavri, BE ;
Chovit, CJ ;
Solis, MS ;
Olah, MR ;
Williams, O .
REMOTE SENSING OF ENVIRONMENT, 1998, 65 (03) :227-248