Seismic Performance of Composite Shear Walls Filled with Demolished Concrete Lumps and Self-Compacting Concrete after Fire

被引:5
作者
Xiong, Yan [1 ]
Chen, Aodong [1 ]
Wu, Di [2 ]
Zhao, Guowei [3 ]
机构
[1] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Peoples R China
[2] Guangzhou Univ, Engn Res & Test Ctr, Guangzhou 510405, Peoples R China
[3] Guangdong Chuangcheng Construct Supervis & Consul, Guangzhou 510075, Peoples R China
基金
中国国家自然科学基金;
关键词
composite shear wall; demolished concrete lumps; fire; quasi-static test; seismic performance; CLADDING PANELS; BEHAVIOR; STRENGTH;
D O I
10.3390/buildings12091308
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to provide a good solution for the treatment and utilization of construction waste, especially waste concrete and to promote the development of green construction to some extent, in this paper, a new composite shear wall filled with demolished concrete lumps (DCLs) and self-compacting concrete (SCC) was proposed, and its seismic performance after fire was investigated. Based on quasi-static tests of four composite shear walls filled with DCLs and SCC, three after a standard fire and one contrastive specimen without fire, the effects of fire exposure time, fire-retardant coating on the edge constraint steel pipe column, and the width-thickness ratio on seismic performance of composite shear walls after fire were studied. The failure patterns, bearing capacity, hysteretic loops, ductility, skeleton curves, rigidity degradation curves, and energy dissipation of shear walls were analyzed and compared. Test results indicate that the bearing capacity of the shear wall after 60 min of standard fire is slightly lower than the contrastive specimen without fire, but specimens still have good seismic performance. The interlayer displacement angle of the shear wall after a fire still meets the requirement of regulations. The fire-retardant coating on the edge of concealed steel pipe column has a limited effect on the seismic performance of specimens after a fire. The horizontal bearing capacity and energy dissipation capacity of shear walls after a fire can obviously be improved by properly increasing the width-thickness ratio.
引用
收藏
页数:20
相关论文
共 42 条
[1]   Properties of Normal Concrete, Self-Compacting Concrete and Glass Fibre-reinforced Self-Compacting Concrete: An Experimental Study [J].
Ahmad, Subhan ;
Umar, Arshad ;
Masood, Amjad .
PLASTICITY AND IMPACT MECHANICS, 2017, 173 :807-813
[2]   Direct tensile testing of Self-Compacting Concrete [J].
Alhussainy, Faez ;
Hasan, Hayder Alaa ;
Rogic, Sime ;
Sheikh, M. Neaz ;
Hadi, Muhammad N. S. .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 112 :903-906
[3]  
Ambroziak Andrzej, 2019, MATEC Web of Conferences, V284, DOI 10.1051/matecconf/201928402001
[4]   Fire resistance of cold-formed steel framed shear walls under various fire scenarios [J].
Andres, Blanca ;
Hoehler, Matthew S. ;
Bundy, Matthew F. .
FIRE AND MATERIALS, 2020, 44 (03) :352-364
[5]  
[Anonymous], 2008, 997832008 GBT ISO
[6]  
[Anonymous], 2016, Code for Seismic Design of Buildings S
[7]   Horizontal cladding panels: in-plane seismic performance in precast concrete buildings [J].
Belleri, Andrea ;
Torquati, Mauro ;
Marini, Alessandra ;
Riva, Paolo .
BULLETIN OF EARTHQUAKE ENGINEERING, 2016, 14 (04) :1103-1129
[8]   Performance of Modular Prefabricated Architecture: Case Study-Based Review and Future Pathways [J].
Boafo, Fred Edmond ;
Kim, Jin-Hee ;
Kim, Jun-Tae .
SUSTAINABILITY, 2016, 8 (06)
[9]   Evaluation of the Seismic Response of Precast Wall Connections: Experimental Observations and Numerical Modeling [J].
Brunesi, E. ;
Nascimbene, R. ;
Peloso, S. .
JOURNAL OF EARTHQUAKE ENGINEERING, 2020, 24 (07) :1057-1082
[10]   Haussmannian building repair, rehabilitation and strengthening: case study from France [J].
Cardoso, Rui .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-ENGINEERING HISTORY AND HERITAGE, 2022, 175 (01) :7-20