Optimization of Castor Oil-Based Ion Selective Electrode (ISE) with Active Agent 1,10-Phenanthroline for Aqueous Pb2+ Analysis

被引:4
作者
Nisah, Khairun [1 ,2 ]
Rahmi, Rahmi [3 ]
Ramli, Muliadi [3 ]
Idroes, Rinaldi [3 ,4 ]
Alva, Sagir [5 ]
Iqhrammullah, Muhammad [6 ]
Safitri, Eka [3 ]
机构
[1] Univ Syiah Kuala, Grad Sch Math & Appl Sci, Banda Aceh 23111, Indonesia
[2] Univ Islam Negeri Ar Raniry, Fac Sci & Technol, Dept Chem, Banda Aceh 23111, Indonesia
[3] Univ Syiah Kuala, Fac Math & Nat Sci, Dept Chem, Banda Aceh 23111, Indonesia
[4] Univ Syiah Kuala, Fac Math & Nat Sci, Dept Pharm, Banda Aceh 23111, Indonesia
[5] Univ Mercu Buana, Fac Engn, Mech Engn Dept, West Jakarta 11650, Indonesia
[6] Jacobs Univ Bremen, Dept Life Sci & Chem, D-28759 Bremen, Germany
关键词
potentiometry; ISE; polyurethane; 1; 10-phenanthroline; lead; MEMBRANE;
D O I
10.3390/membranes12100987
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This research has successfully fabricated ion selective electrode (ISE) for Pb2+ using castor oil (Ricinus communis L.)-based polyurethane (PU) membrane with 1,10-phenanthroline as the active agent. The sensitivity of the Pb2+ ISE obtained is 27.25 mV/decade with a linear range of [Pb(NO3)(2)] of 10(-10)-10(-5) M and a coefficient of determination (R-2) of 0.959. The system response reaches stability after 25 s of measurement. The Pb2+ has a detection limit of 10(-10) M and gives a stable response at pH 7-8 with a 15-day lifetime. The investigation of the selectivity of the ISE was performed using the mixed solution method with log Kij values of Ca2+ > K+ > Mg2+ > Cu2+ > Fe3+ > Cr3+> Zn2+ > Cd2+. The Pb2+ ISE shows acceptable reproducibility and repeatability with standard deviation values of 0.065 and 0.0079, respectively. Fourier transform infrared (FT-IR) spectra confirmed that 1,10-phenanthroline was responsible for the formation of the Pb2+ ion entrapment via complexation. Other characterizations (crystallinity, micro-surface morphology, and mechanical strength) suggest the degradation of the membrane structure integrity after the application. The analysis results of Pb levels using the Pb2+ ISE in artificial and wastewater samples were not significantly different from the atomic absorption spectroscopy (AAS) measurement.
引用
收藏
页数:15
相关论文
共 43 条
[11]   Effect of AgNPs internal solution on the sensing of mercury(II) by an ion-selective electrode based on a thiol coordination from cysteine as ionophore [J].
Elgamouz, Abdelaziz ;
Shehadi, Ihsan ;
Assal, Abdelrahman ;
Bihi, Alaa ;
Kawde, Abdel-Nasser .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895
[12]  
Food and Drug Administration, 2015, ELEMENTAL IMPURITIES, P1
[13]  
Ganjali M.R., 2006, ENCY SENSORS, VVolume 8, P203
[14]   Fast Potentiometric Analysis of Lead in Aqueous Medium under Competitive Conditions Using an Acridono-Crown Ether Neutral Ionophore [J].
Golcs, Adam ;
Horvath, Viola ;
Huszthy, Peter ;
Toth, Tunde .
SENSORS, 2018, 18 (05)
[15]   Synthesis and characterization of nano-cellulose immobilized phenanthroline-copper (I) complex as a recyclable and efficient catalyst for preparation of diaryl ethers, N-aryl amides and N-aryl heterocycles [J].
Hosseinzadeh, Rahman ;
Aghili, Nora ;
Mavvaji, Mohammad .
POLYHEDRON, 2022, 213
[16]   The Effects of Cyclic Isothermal Oxidation on Ir/IrOx pH Electrode and a Method to Correct the Potential Drift of Metal Oxide Electrode [J].
Huang, Feifei ;
Wan, Zhengwei ;
Jin, Ying ;
Wen, Lei .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (13) :B632-B640
[17]   Lead ion-selective electrodes based on polyphenylenediamine as unique solid ionophores [J].
Huang, Mei-Rong ;
Rao, Xue-Wu ;
Li, Xin-Gui ;
Ding, Yong-Bo .
TALANTA, 2011, 85 (03) :1575-1584
[18]   Selective Determination of Diclofenac and Clomiphene with a Single Planar Solid-State Potentiometric Ion Selective Electrode [J].
Hussien, Emad Mohamed ;
Derar, Abeer .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (10) :B780-B786
[19]   Influence of phosphate buffer and proteins on the potentiometric response of a polymeric membrane-based solid-contact Pb(II) ion-selective electrode [J].
Joon, Narender Kumar ;
He, Ning ;
Wagner, Michal ;
Cardenas, Marite ;
Bobacka, Johan ;
Lisak, Grzegorz .
ELECTROCHIMICA ACTA, 2017, 252 :490-497
[20]   Selective and sensitive lead (II) solid-contact potentiometric sensor based on naphthalene-sulfonamide derivative [J].
Kamal, A. ;
Tejpal, R. ;
Bhalla, V. ;
Kumar, M. ;
Mahajan, R. K. .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2015, 12 (08) :2567-2578