A thermodynamic analysis of a transcritical cycle with refrigerant mixture R32/R290 for a small heat pump water heater

被引:48
作者
Yu, Jianlin [1 ]
Xu, Zong [1 ]
Tian, Gaolei [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Refrigerat & Cryogen Engn, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump; Transcritical cycle; Mixture; Propane; HFC; Performance; PROPANE R290; CO2; PERFORMANCE; SYSTEMS; DESIGN; DIFLUOROMETHANE; EXCHANGER;
D O I
10.1016/j.enbuild.2010.08.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, a thermodynamic analysis on the performance of a transcritical cycle using azeotropic refrigerant mixtures of R32/R290 with mass fraction of 70/30 has been performed. The main purpose of this study is to theoretically verify the possibility of applying the chosen refrigerant mixture in small heat pumps for high temperature water heating applications. Performance evaluation has been carried out for a simple azeotropic mixture R32/R290 transcritical cycle by varying evaporator temperature, outlet temperature of gas cooler and compressor discharge pressure. Furthermore, the effects of an internal heat exchanger on the transcritical R32/R290 cycle have been presented at different operating conditions. The results show that high heating coefficient of performance (COP(h)) and volumetric heating capacity can be achieved by using this transcritical cycle. It is desirable to apply the chosen refrigerant mixture R32/R290 in small heat pump water heater for high temperature water heating applications, which may produce hot water with temperature up to 90 degrees C. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2431 / 2436
页数:6
相关论文
共 20 条
[1]   Combined air conditioning and tap water heating plant using CO2 as refrigerant [J].
Adriansyah, W .
ENERGY AND BUILDINGS, 2004, 36 (07) :690-695
[2]   Vapor-liquid equilibrium measurements and correlations for the binary mixture of difluoromethane plus isobutane and the ternary mixture of propane plus isobutane plus difluoromethane [J].
Akasaka, Ryo ;
Higashi, Yukihiro ;
Tanaka, Katsuyuki ;
Kayukawa, Yohei ;
Fujii, Kenichi .
FLUID PHASE EQUILIBRIA, 2007, 261 (1-2) :286-291
[3]   VLE measurements and modeling for the strongly positive azeotropic R32+propane system [J].
Bobbo, S ;
Fedele, L ;
Camporese, R ;
Stryjek, R .
FLUID PHASE EQUILIBRIA, 2002, 199 (1-2) :175-183
[4]   Optimized design of a heat exchanger for an air-to-water reversible heat pump working with propane (R290) as refrigerant:: Modelling analysis and experimental observations [J].
Castro, JB ;
Urchueguía, JF ;
Corberán, JM ;
Gonzálvez, J .
APPLIED THERMAL ENGINEERING, 2005, 25 (14-15) :2450-2462
[5]   Propane heat pump with low refrigerant charge: design and laboratory tests [J].
Fernando, P ;
Palm, B ;
Lundqvist, P ;
Granryd, E .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07) :761-773
[6]  
GAO ZM, 2006, P 9 AIAA ASME JOINT, P2006
[7]   Simulation and performance evaluation of finned-tube CO2 gas coolers for refrigeration systems [J].
Ge, Y. T. ;
Cropper, R. T. .
APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) :957-965
[8]   Experimental determination of the critical locus for the difluoromethane (R32) and propane (R290) system [J].
Higashi, Y .
FLUID PHASE EQUILIBRIA, 2004, 219 (01) :99-103
[9]   Cooling performance of several CO2/propane mixtures and glide matching with secondary heat transfer fluid [J].
Kim, Ju Hyok ;
Cho, Jin Min ;
Kim, Min Soo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05) :800-806
[10]   Fundamental process and system design issues in CO2 vapor compression systems [J].
Kim, MH ;
Pettersen, J ;
Bullard, CW .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2004, 30 (02) :119-174