Test of GEANT3 and GEANT4 nuclear models for 160 MeV protons stopping in CH2

被引:38
作者
Paganetti, H [1 ]
Gottschalk, B
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, High Energy Phys Lab, Cambridge, MA 02138 USA
[3] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
D O I
10.1118/1.1586454
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Monte Carlo simulations are used for many problems in proton radiation therapy, some of which are sensitive to the nuclear interaction model. The available models have been little tested in the regime of interest, namely in their ability to predict the secondary particle yield, including their angle and energy, when 70-250 MeV protons stop in various materials. The present study provides one such test in carbon, complementing a previous one in copper. Using a multilayer Faraday cup we have measured the projected range distribution of charged nuclear secondaries from 160 MeV protons stopping in polyethylene (CH2). To test the popular GEANT Monte Carlo we have simulated the experiment with GEANT3 using the "Gheisha" (default) and "Fluka" models' and with GEANT4.5 using the "low-energy" and "precompound" models. The GEANT3/Fluka and GEANT4/precompound simulations agree moderately well with the observed range distribution. The data are given in a convenient form for testing other Monte Carlo programs. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:1926 / 1931
页数:6
相关论文
共 16 条
[1]   Secondary neutron and photon dose in proton therapy [J].
Agosteo, S ;
Birattari, C ;
Caravaggio, M ;
Silari, M ;
Tosi, G .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :293-305
[2]   Monte Carlo and analytical calculation of proton pencil beams for computerized treatment plan optimization [J].
Carlsson, AK ;
Andreo, P ;
Brahme, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (06) :1033-1053
[3]  
CARMINATI F, 2001, GEANT4 BENCHMARK HAD
[4]  
Ferrari A, 1997, SOC ITAL FI, V59, P247
[5]  
FESELFELDT HC, 1985, 8502 RWTH PITHA
[6]   Nuclear interactions of 160 MeV protons stopping in copper: A test of Monte Carlo nuclear models [J].
Gottschalk, B ;
Platais, R ;
Paganetti, H .
MEDICAL PHYSICS, 1999, 26 (12) :2597-2601
[7]  
ICRU, 2000, icru Report
[8]  
Janni J. F., 1982, Atomic Data and Nuclear Data Tables, V27, P147, DOI 10.1016/0092-640X(82)90004-3
[9]   Effects of nuclear interactions on energy and stopping power in proton beam dosimetry [J].
Laitano, RF ;
Rosetti, M ;
Frisoni, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 376 (03) :466-476
[10]   Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50-250 MeV) [J].
Medin, J ;
Andreo, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (01) :89-105