Mesoporous nickel electrodes plated with gold for the detection of glucose

被引:17
作者
Ling, Tzong-Rong [1 ]
Li, Chia-Shun [2 ]
Jow, Jiin-Jiang [2 ]
Lee, Jyh-Fu [3 ]
机构
[1] I Shou Univ, Dept Chem Engn, Kaohsiung 84008, Taiwan
[2] Natl Kaohsiung Univ Appl Sci, Dept Chem & Mat Engn, Kaohsiung 80778, Taiwan
[3] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
关键词
Au deposition; Glucose sensor; Mesoporous nickel electrode; ELECTROCHEMICAL SENSOR; CARBON; FILMS; NANOPARTICLES; FABRICATION; DEPOSITION; OXIDE;
D O I
10.1016/j.electacta.2010.10.041
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Mesoporous nickel electrodes (MNEs) are efficient structural materials for advanced electrochemical sensors due to their extremely high surface areas. However, the poor oxidation resistance of nano-sized nickel in air severely limits their applications. Thus, the purpose of the present study was to improve the oxidation resistance of MNEs by applying relatively stable gold coatings via electroplating. The results revealed that the gold coatings provided excellent oxidation resistance to MNEs, and a loss in amperometric sensitivity for glucose sensing was not observed. The protection time increased with an increase as the thickness of the gold coating (passing charges of 0-25.49 C/cm(2)), and protection times ranging from a few hours to 2 weeks were obtained. With an alkaline electrolyte (NaOH, 4 M). MNEs exhibited excellent sensitivities. For instance, the sensitivity of the unmodified MNE and the Au coated-MNE was 3238 and 2978 mu A mM(-1) cm(-2), respectively. Thus, coated and uncoated MNEs displayed remarkably higher linear sensitivities than conventional nickel-based electrodes (394 mu A mM(-1) cm(-2)) at a wide range of glucose concentrations (0.001-3 M). (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1043 / 1050
页数:8
相关论文
共 41 条
[1]   Mesoporous platinum films from lyotropic liquid crystalline phases [J].
Attard, GS ;
Bartlett, PN ;
Coleman, NRB ;
Elliott, JM ;
Owen, JR ;
Wang, JH .
SCIENCE, 1997, 278 (5339) :838-840
[2]   Lyotropic liquid crystalline properties of nonionic surfactant/H2O/hexachloroplatinic acid ternary mixtures used for the production of nanostructured platinum [J].
Attard, GS ;
Bartlett, PN ;
Coleman, NRB ;
Elliott, JM ;
Owen, JR .
LANGMUIR, 1998, 14 (26) :7340-7342
[3]   Development of highly sensitive non-enzymatic sensor for the selective determination of glucose and fabrication of a working model [J].
Babu, T. G. Satheesh ;
Ramachandran, T. .
ELECTROCHIMICA ACTA, 2010, 55 (05) :1612-1618
[4]   The preparation and characterisation of H1-e palladium films with a regular hexagonal nanostructure formed by electrochemical deposition from lyotropic liquid crystalline phases [J].
Bartlett, PN ;
Gollas, B ;
Guerin, S ;
Marwan, J .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2002, 4 (15) :3835-3842
[5]   Preparation and characterization of H1-e rhodium films [J].
Bartlett, PN ;
Marwan, J .
MICROPOROUS AND MESOPOROUS MATERIALS, 2003, 62 (1-2) :73-79
[6]   Electrochemical reduction of oxygen on mesoporous platinum microelectrodes [J].
Birkin, PR ;
Elliott, JM ;
Watson, YE .
CHEMICAL COMMUNICATIONS, 2000, (17) :1693-1694
[7]   Ionic strength-controlled virtual area of mesoporous platinum electrode [J].
Boo, H ;
Park, S ;
Ku, BY ;
Kim, Y ;
Park, JH ;
Kim, HC ;
Chung, TD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (14) :4524-4525
[8]   A nonenzymatic glucose sensor using nanoporous platinum electrodes prepared by electrochemical alloying/dealloying in a water-insensitive zinc chloride-1-ethyl-3-methylimidazolium chloride ionic liquid [J].
Chou, Chih-Hung ;
Chen, Jyh-Cheng ;
Tai, Chia-Cheng ;
Sun, I-Wen ;
Zen, Jyh-Myng .
ELECTROANALYSIS, 2008, 20 (07) :771-775
[9]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[10]   Detection of hydrogen peroxide at mesoporous platinum microelectrodes [J].
Evans, SAG ;
Elliott, JM ;
Andrews, LM ;
Bartlett, PN ;
Doyle, PJ ;
Denuault, G .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1322-1326